| 1 | Taking down old Unsv LTUG cables of size upto 50 Sqmm from trenches / poles / ducts etc complete all as specified and directed. |
| 2 | Supplying, laying, jointing, commissioning and testing XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugsof appropriate size, pvc sleeve etccomplete all as directed by Engr-in-Charge for following sizes:- Make :- Havells / Gloster / Finolex / PolycabNOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule . |
| 3 | 50 Sqmm 3.5 core . |
| 4 | 35 Sqmm 3.5 core |
| 5 | 25 Sqmm 3.5 core |
| 6 | 16 Sqmm 4 core. |
| 7 | 10 Sqmm 2 core |
| 8 | 6Sqmm 2 core |
| 9 | Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 10 | Ditto item No. 3 above but in hard/dense soil complete all as specified and directed. |
| 11 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & dierected. |
| 12 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge. |
| 13 | Material and Labour for riddled earth forcushioning to under ground electric cable including spreading , levelling and hand punning complete all as specified and directed.Note - Punned thickness shall only be measured & paid . |
| 14 | Material & Labour for road cutting / foot pathand making good with PCC M-10 grade (nominal mix) using 40 mm graded stone aggregate of 150mm X 100mm in respect ofwidth and thickness complete all as specified and directed. |
| 15 | Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mmfor under ground cable complete all as specified and directed. |
| 16 | Supply & fixingin repair light grade GI pipe of size 40 mm dia conforming to IS 1239 (Part-1): 2004 laid in trenchs or under floors or fixed on polefor cable protection complete all as specified and directed. |
| 17 | Supply & fixingin repair light grade GI pipe of size 80 mm dia conforming to IS 1239 (Part-1): 2004 laid in trenchsunder floors or fixed on polefor cable protection complete all as specified and directed. |
| 18 | Material and Labour for plain cement concrete (PCC) 1:3:6, type C2(40mm graded stone aggregate) for making foundation of Pole/stay assembly complete all as specified and directed. |
| 19 | Material and Labour for plaincement concrete (PCC) 1:3:6, type C1 (20mm graded stone aggregate) for making copings of Poles etc complete all as specified and directed. |
| 20 | Material and labour in repair for Earthing complete with GI earthplate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 40 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified & directedNote : Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth. |
| 21 | Material and labour in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 mtr deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level , connected to 32 mm x 6 mm GI stripas earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge.CI cover with frame, 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point complete all as specified and directed on testing on completion. Note : Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth. |
| 22 | Material & Labour for detection of street light cable fault with and including technician, cable fault location inachive kit detect the cable fault, includingnecessary excavation of soil / road, hard standing, foot pathand refilling the soil, after jointing the faulty cable with new straight through joint kit, testing of cable complete all as specified & directedNote: Cable joint of required size shall be measured and paid separately under relevant item of this BOQ as Supply & fixing . |
| 23 | Supply and fixjoint,heat shrinkable type straight through joints for joint LT UG cable 1100 volts grade of size upto 16 sqmm, 2 core/ 3.5 core/ 4 core, complete all as specified & directed |
| 24 | Supply and fix joint heat shrinkable type straight through jointsfor joint LT UG Cable 1100 volts grade of size 25 to 50 sqmm, 3.5 core/ 4 core, complete all as specified & directed |
| 25 | Supply and fix in repairbrass terminal of capacity 63 Amp/ 100Amp 4 pole complete with nut, bolts, washer, complete with backlite/ fibre insulator complete including fixing inside street light junction box complete all as specified and directed . |
| 26 | Taking down old unserviceable rusted damagedstreet light pole of any typefrom site complete all as specified and directed. |
| 27 | Supply and errect in vertical position Steel tubular swaged poles in repair,type 410 SP- 31 (09 mtr long) with 300mm x 300mmx6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirementall as specified including factory painted with two coats ofblack bituminous paint internally through out and externally for embeded portion and applying one coat of red oxide primer, making 05 Nos strip each 30 cmhigh with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 meter, painting with two coats of aluminium paint for the remaning height complete all as specified and directed.Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch. |
| 28 | Taking down old unserviceable Flood lightfitting of any type/capacity from its location complete all as specified and directed. |
| 29 | Supply and Fix in repair LED Floodlight fitting of capacity 120 wattsmade up of pressure die cast aluminium housing with toughned glass and high power LED\"s and secondary lenses, having system efficiency greater than 110 lumen per watts with surge protection device included. The luminaries shall be totally enclosed dust and water proof with minimum IP -66 protection pre wired up to connector including 2.5 sq mm PVC insulated cable for making connection (upto 9 mtr length), complete all as specified and directed by Engr-in-charge.Make :- Halonix/Crompton/Havells/Philips/Benlo. |
| 30 | Ditto all as per item No. 23 above but for capacity of 150 watts |
| 31 | Ditto all as per item No. 23 above but for capacity of 200 watts |
| 32 | Dismantling and Taking down old unserviceable street light fitting of capacityupto 120 watts from itslocation complete all as specified & directed. |
| 33 | Supply andFix in repair LED Street light fitting of 90 Watt / 100 Watt (Cool White) including LED lens complete with body robust, corrosion resistant, superior finish, made up of high pressure die cast aluminium alloy housing. The luminaries shall be totally enclosed, dust and water proof with minimum IP - 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 to 300 V, AC, frequency 50 to 60 Hz, P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% , cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection . The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including provision of connection for street light from pole box with 2.5 Sqmm PVC insulated stranded copper conductor FRLSH cable (upto the lenght of 9 mtr) complete all as specifiedand directed by Engineer-in- charge.Make :- CROMPTON / HALONIX /BENLO |
| 34 | Ditto as per item No. 25 above but for capacity of 60 Watt Make:- CROMPTON/ HALONIX /BENLO |
| 35 | Ditto as per item No. 25 above but for capacity of 45 Watt Make:- CROMPTON / HALONIX /BENLO |
| 36 | Supply & fixingin repairsBracket for fixing of street light fittings bend to shape, made out of40 mm dia GI pipe medium grade upto 1.5 mtr long fixed withtwo sets of MS clamps made out of flat iron of size 50 mm x 6 mm fabricated to shape and fixed with nuts bolts and washers& two coats of aluminiumpaints over and including a coat of red oxide primer complete all as specified and directed by Engr-in-Charge(Note : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item) |
| 37 | Supply & fixingthree core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all as specified and directed by Engr-in-charge. |
| 38 | Supply & fixingin repair LED bollard light, with aluminium housing with acrylic diffuser of capacity 10 W /15 W inverted pyramid tripod type LED bollard with soft 360 degree light distribution with IP 65/66 protection, bollard length should be 800mm complete with all accessories complete all as specified and directed.Make :- Crompton cat no LBLSN-10-CDL or equivalent in Halonix/Wipro/Surya. Note :- The quoted rates is inclusive of excavation and foundation work of PCCof size 0.30mtr (L) x 0.3mtr (B) x 0.60 mtr(H) complete all as specified and directed for fixing of Bollard light fittings. |
| 39 | Supply & fixingin repair LED post top lantern 40W aluminium housing, with IP 65/66 protection, clear acrylic diffuser, die cast aluminium spigot , spun aluminium powder coated top cover complete with accessoireswith suitablesize40/50/60 mm outer dia GI pipe and plastering work wherever reqd complete all as specified & directed.Make :- Halonix cat No. HLPT-04-40-CW or equivalent in Crompton/ Wipro/Surya. |
| 40 | Supply & fixing in repair junction box of size not less then 325mm x 220mm x 150mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 66 / 67 for outdoor Installation with internallly embedded gasket (PUR) including the box fitted with connector 8 way 40 Amps 01 No including Emlex stud type TB 4 Nos incoming / outcoming cable at controlled with MCB SP 6 Amps 01 No & enclosed along pole including fixing with steel tubular poles with two Nos FI clamps 25mm x 3mm withnuts, bolts and washers complete and making connection with 1.5 sqmm copper conductor unsheathed FRLS PVC insulated 3 core from junction box to security lights fittings duly laid inside the streel tubular pole and bracket complete all as specified & directed.Note : (40 mm bore GI pipe light grade, 3 core 1.5 sqmm cable and GI brackets will be measured separately . Make :- Sintex Cat Part No. GSJB-3726 or equivalent in Indokop / HenselNote :- Cost of flat iron clamp is deemed to include in unit rate of this items. |
| 41 | Material and Labour for repairing of street light fitting / luminaries of any capacity / type with replacement of burnt control wiring, LED drivers 45watt / 60 watt / 90 watt etc complete all as specified and directed. Note - (i)Cost of replacement of driver will bemeasured and paid separately under relevant item of schedule .(ii)Quoted rates is inclusive of T&P required for doing the complete job from any height. |
| 42 | Supply only LED Drivers of street light fitting suitable for 45 watt / 60 watt capacity street light fitting complete all as specified and directed. |
| 43 | Supply only LED Drivers of street light fitting suitable for 90 watt / 100 watt / 120 watt capacity street light fitting complete all as specified and directed. |
| 44 | Material and Labourfor surface preparing by old paintremoving by scrubbing with embry paper / wire brush and painting tosteel tubular pole 9/11 metre long (any type)with two coats of epoxy based paint aluminium grade paint over and including one coat of red oxide primer and painting up to 1.5 Mtr above PCC coping in black and white strips 5 Nos each 30 cm high starting from bottom of pole including writing of pole number with black enemelled paint of 25 mm high letters in 10 cm dia circle in white paint complete all as specified and directed. |
| 45 | Supply and fix in repair Astro time switch with more than 100 hrs battery back up working on 240 volts , 50 Hz AC supply as per cat No AUTS02AST00 of L&T make or equivalent make of Indoasian/Havells . |
| 46 | Supply and fix in repair 4 pole power contactor of capacity63 Amps , 415 volts AC for street light timer panel complete all as specified and directed. |
| 47 | Supply and fix in repair MCB 4 poleof capacity63 Amps \"C\" curve , 415 volts including necessary disconnection of incoming and outgoing cable complete all as specified and directed. |
| 48 | Supply and fix in repair MCB SP of capacity6 Amps to 32 Amps \"C\" curve , 240 volts including necessary disconnection of incoming and outgoing cable complete all as specified and directed. |
| 49 | Material and Labour for triming of tree branches with in 2.0 mtr on either side of the electric line/Steet light poles and timmer panels and E/M installation with suitable T & P and desposing the waste complete all as specified and directed. |
| 50 | Material and Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 51 | Taking down old LED strip of any type from poles and boards and Supply and fix decorative type Tri colour LED strip, out door type of 16 mtr lenght with connection service wire of required length at poles and boards of various locations,complete all as specified and directed by Engr-in-charge. Note: (i) The rates are inclusive of service wire for connection from nearby pole/panel of required length upto 10 mtr distance. (ii) Quoted rates is inclusive of T&P required for doing the complete job from height upto 10 mtrs. |
| 52 | Taking down unserviceable street lightpanel and Supply, install, commissioning and testing of street light panel outdoor type 415 V/440 Volts of size not less then 0.6 mtr x 0.6 mtr x .03 mtr, confirming to IEC 61439 with IP-54 protection of suitable size made out of 3.15 mm thick CRCA sheet with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door,doors of the panel should be removable type,3 phindicators lamp etc with provision for 02Nos of 2 Pole 32 Amp MCB out going, 01 No IncomingTPN 63Ampwith Analog street light timer cat No AUTS02AST00 of L&T, copper panel control wiring as per IS direction,make internal compartment for mounting MCBs, the panel shall be mounting on 50 x 50 x 6 mm MS angle iron and 60 cm above the normal ground level & embedded 20 cm below ground level in PCC foundation (1:2:4) type B 1 (20mm graded stone aggregate), connect new UG cable for Incoming from LT panel cable shall enter through cable glands for safety of cable where enter through panel complete all as specified and directed by Engr-in-charge. |
| 53 | Supply and fixing in repair LED Tiranga Light column of 4 mtr heightwith cylindericalaluminium pipe housing, opaque diffuser made out of engineering grade polymer with IP -65 protection with power output 50 wattscomplete with all accessories and as specified and directed .Make :- Shakti cat No - SZPGCM X 050-4M or equivalent in Halonex/Wipro/Surya. Note :- (i)The quoted rates is inclusive of excavation and foundation work of Pccas recommended by OEM and Engr- In- Charge.(ii) The rates are inclusive of PCC coping of size 300mm(L) x 300mm(B) x 600mm (H) to each pole |
| 54 | Supply and fixing in repair LED Post top gate light luster with pole of dia 55mm (OD) made out of CRCA/GI bodyduly poweder coated of height 3.5 mtr including decorative LED post top lantern, cast aluminium housing with asthetically designed diffuser and reflector to deliver uniform light output OD of 55mm dia pipe with IP -65 protection with power output 45 wattscomplete with all accessories and as specified and directed .Make :- Shakti cat No - SZPGCM X 045-IP or equivalent in Halonex/Wipro/Surya. Note :- (i)The quoted rates is inclusive of excavation and foundation work of Pccas recommended by OEM and Engr- In- Charge.(ii) The rates are inclusive of PCC coping of size 300mm(L) x 300mm(B) x 300mm (H) to each pole |