| 1 | Surface dressing nexc 30cm deep and averaging 15cm deep in soft and loose soils , complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft/loose soil , complete all as specified and directed. |
| 3 | M&L PCC 1:4:8 type D-2 using 40 mm graded stone agg in foundation filling and mass concrete complete all as specified and directed |
| 4 | M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work & concrete, finished even and smooth complete all as specified & directed. |
| 6 | M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work & concrete, finished even and fair on external wall surfaces complete all as specified & directed. |
| 7 | M and L for coloured Glazed ceramic tiles350X250mmX7mm/450x350x7 mmthickset and jointed in neat cement slurry and pointed in coloured cement to match the flooras on vertical surfaces laid over 10mm thick cement screed in 1:4. complete all as specified and directed |
| 8 | M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 9 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed. |
| 10 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even andrough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 11 | M & L for Machine cut kota stone slab flooring 18-20 mm thickover and including screed bed or bedding layer 20 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.. |
| 12 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 13 | S&F Mild steel workin tubular poles & trusses (framed) including purlins,rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 , complete all as specified and directed. |
| 14 | M&L PCC 1:3:6 type C1, 75 mm thick finished even and smooth without using extra cement as in plinth protection including forming of joints 10mm wide and 75mm deep and joint filled with bitumin and sand mixture in 1:1 ratio complete all as specified and directed |
| 15 | Supplying and layingof CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections , complete all as specified and directed. |
| 16 | Supplying and layingof CPVC pipes 32mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed. |
| 17 | S & F in repairfor CP bib taps 15mm fancy type Chromium Plated cast copper alloy with crutch or butterfly handle , complete all as specified and directed. |
| 18 | S & F in repair Angle valve cast copper alloy with capstan head chromium plated screwed down high pressurewith long shanks and fly nuts screwed for 15mm bore pipe , complete all as specified and directed. |
| 19 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 20 | Excavating in trenches not exceeding 1.5 meter depth wide andexceeding1.5 meter and not exceeding 3meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/loose soil all as specified and directed. |
| 21 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 22 | Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 23 | Supply and fix double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified and directed |
| 24 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
| 25 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
| 26 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as directed |
| 27 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof50mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 28 | Taing out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete, all as specified and directed. |
| 29 | Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc with necessary cable lugs /sockets and glands of cross sectional area for 10 Sqmm 2 Core,complete, all as specified and directed . |
| 30 | All as per item no. 29 but for 16 Sqmm 2 Core. |
| 31 | All as per item no. 29 but for10 Sqmm 4 Core. |
| 32 | All as per item no. 29 but for25 Sqmm 3.5 Core. |
| 33 | M/L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia med grade,funnel,wire mesh,protection pipe 40 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 34 | M/L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iGI strip 32x6 mm as earthing leadmeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia med grade,funnel,wire mesh,protection pipe 40 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 35 | Supply and fixing of moulded case circuit breaker Four pole 100 Amps 16 KA capacity 415V 50Hz with Ics = 50% Icu as per IEC 60947-II suitable for isolation class II front face fixed overload and fixed short circuit setting. taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 36 | S & F in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedde PC coverhaving bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK08 with suitable for pole dia 42 mm of capacity 45 watts complete all as specified and directed. |
| 37 | S & F in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedde PC coverhaving bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK07 with suitable for pole dia 42 mm of capacity 60 watts complete all as specified and directed. |
| 38 | Supply and fixing in replacement of LED driver for suitable for 45W to 60 W complete all as specified and directed by Engr-in-Charge. Make :- As per Sample) |
| 39 | Supply and Fix in repair for PVC junction box of size 270 x 225 x 135 mm with Aluminium bus bar 200 Amps capacity -4 No\"s. MCB SP 6 Amp - 1 No and having provision of cable hole in bottom for two to three armoured cables of size 25 Sqmm 3.5 core, connection box shall be fitted on street light pole and fixing arrrangements i.e. MS clamps etc deemed to be provided by the contractor all as specified and directed . |
| 40 | Re fixing of serviceable JB box of any type or size complete all as specified and directed |
| 41 | Taking down and replacement ofexisting unserviceable street light fitting bracket with new brackets made out of 32mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall, painting with two coats of aluminium paint over a coat of red oxide primercomplete, all as specified and directed. (MS clamps nut bolts etc will be measured and paid seperately) |
| 42 | Taking downexistingstreet light fitting bracket of any size frompole/wall and repair/ painting with two coats of aluminium paint over a coat of red oxide primercomplete and re- fixing on pole all as specified and directed. (MS clamps nut bolts etc will be measured and paid seperately if required) |
| 43 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 to 25 sqmm complete |
| 44 | Checking of street/security lights breakdown maint of overhead lines/9 mtr pole/swan neck polesby checking out the cables/carbon removel /connectors/mcbs etc and locating the fault and replacing with necessary cables for jumpers/ clamps & connectors/terminal box etc, making good, cleaning and lubricatingtheparts etc complete all as specified and as directed : Note 1: quoted rate inclusive of vehicle with ladder and T&P required for completing the Job .Note 2 Drivers/PCBs/cables/fittings/terminal box/ disc/pin insulators, are measured and paid separately under relavent items |
| 45 | Supply and fix in replacement of Timer panel, made of MS Enclosure factory made consisting Astronomical timer with max load of 12 KW with 65 A TP contactor with MCB 63 Amp TPN three phase 415 volts conforming to IS/IEC 60947-4-1, provided with protection degree IP 54 with internal wiring FRLS copper cable, in built shor-circuit-protection, class H insulation complete as as specifed and directed with suitable size of angle iron frame and necessary PCC Wk all as specified and as directed by Engr-n-charge |
| 46 | M&L for taking down the motorised / manual High Mast Lights circular grid accomodating MH/MV light fittings any cap over a ht of 15 mtrto the ground, taking aside, replacing the unsv control gears/ light fittings with LED fixtures and raising back to its original position upto 15 mtr etc complete all as specified and as directed (Rates quoted shall be incl of replacing required accessories where specifically not mentioned but required to complete the Job except LED fixtures)for taking down,Necessary T&P items required for lowering the circular grid shall be in possession with contr ie suitable handle for mannual operationor spare motor for lowering with cable required for completing the job all as directed. |
| 47 | M&L repairing the Light fittings ofthe motorised / manual High Mast Lights of any size and capacity of light fittings by taking down the mast with the help of craneover a ht of 15 mtrto the ground, taking aside, replacing the unsv control gears/ light fittings with LED fixtures and raising back to its original position upto 15 mtr etc complete all as specified and as directed (Rates quoted shall be incl ofcrane and replacing required accessories where specifically not mentioned but required to complete the Job except LED fixtures) |
| 48 | S&F in replacement astronomical + digital time switchcomplete all as specified and directed. |
| 49 | Supply and fix in replacement of automatic modular contactor with 3NO+1NC, 40A, 3 module, 50HZ suitable for timer switch of street light complete all as specified and directed |
| 50 | Boring of holes horizontally for laying of 40mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 51 | M&L in replacement ofnew generation energy saving and environmental friendly, long, life pressure die cast aluminium housing flood light with PC diffused lens enclusre over LED for glare free light of capacity 120 watts, 240 volts, 50Hz complete all as specified and directed. |
| 52 | M & L for Cutting and trimming of tree branches 3 mtr all around of any size which is obstructing illumination of street light and touching LTOver head line by using required tools and plants incl removing trimmed tree branches, complete all as specified and directed. (Note : Each cleaning will be measured and paid separetely) |
| 53 | Supply and fixing in repairs SP 5-32 amp rating 240V, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning ,complete all as specified and directed |
| 54 | Supply and fixing in repairs SPN 32-40 amp rating 240V, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning , complete all as specified and directed |
| 55 | Boring of holes horizontally for laying of 40mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 56 | S&F in repairs PVC insulated and FR PVC round sheathed copper conductor(flexible), 1100 volts, conforming to IS 694 of size1.0 Sqmm 3 core complete all as specified and directed |
| 57 | Re fixing of serviceable PVC insulated pvc sheathed copper conductor(flexible), 1100 volt of size1.0 Sqmm 3 core/ or any size on poles from light fitting to JB box or any situvations complete all as specified and directed |
| 58 | M&L for in repairs service wire sheathed flat 2 core aluminium conductor of size6 Sqmm, 1100 volts grade complete all as specified and directed |
| 59 | S&F in repairs PVC conduit pipes 19 mm outer dia corrsion free, thermal resistance -5 degree to +60 degree celcius, self extinguishing complete all as specified and directed |
| 60 | S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed. |
| 61 | Taking out old UNSVXLPE/PVC insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor fromtrenches, from poles/walls etc cross sectional area for 10 Sqmm to 16 sqmm 4 / 2 Core complete, all as specified and directed :-(Excavation/Earth wk will be measured and paid seperately) |
| 62 | All as per item no. 6125 Sqmm 3.5 Core. |
| 63 | Relaying of serviceable U/G cable retrived from site of size 10 to 35 sqmm 2/4 core complete all as specified and directed .( Cable protection pipe /sand brick etc will be measured and paid seperately) |
| 64 | Relaying of serviceable U/G cable retrived from site of size 50 to 95 sqmm 2/3.5/4 core , complete all as specified and directed.( Cable protection pipe /sand brick etc will be measured and paid seperately) |
| 65 | Relaying of old serviceable pcc cable protection cover/bricks retrived from site, complete all as specified and directed |
| 66 | Relaying of old serviceable old serviceable HDPE/PVC cable protection pipes retrived from site, complete all as specified and directed |
| 67 | M&L GI pipe Light gde 15 mmdiafor earth lead protection, complete all as specified and directed |
| 68 | Cutting chases and making good and cement work in any wall /floors and making good with PCC1:3:6 complete all as directed |
| 69 | Horizontal auguring of Road path etc for passing cables/pipes and making good ,complete all as specified and directed |
| 70 | Excavation of concreate or Road surface for laying of cables or pipes and making good the disturbed patch with PCC 1:3:6 ,complete all as specified and directed |
| 71 | M&L Cutting chases and making good and cement work in any wall /floors and making good with PCC and Glazed Tiles of existing size and colour and matching with the surface of walls or floors all as directed |
| 72 | All as per item no. 71 but except Tiles |