| 1 | Demolition of cement concerte including tiles in ground floors and paving n exc 15 cm thickness (below or above ground level )unreinforced concrete. |
| 2 | M&L 25mm thick Plain Cement concrete type B-0, 1:2:4 (12mm graded aggregate) Laid in flooring as specified and directed by Engineer In charge. |
| 3 | Material and labour forfor Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchlaid over and including 15 mm thick screed bed/bedding layer in CM (1:6) complete all as specified and as direcetd. |
| 4 | Taking down plaster/ tiles on brick or stone walls, etc. in cement lime or cement mortar complete all as specified and as direcetd. |
| 5 | Material and labour forfor digital coloured glazed ceramic tiles of sizes 300m x 450 mm X 7 mm thick jointed in neat cement slurry, laid over including 10 mm thick rendering coat/backing layer in CM (1:4) and pointed in white or coloured cement to match the shade of tile as in vertical surfaces such as dado/skirting complete all as specified and as direcetd. |
| 6 | M&L for rendering to brick masonry or stone surfaces 15mm thick in cement mortar 1:4,to be finished even andsmooth (without using extracement complete all as specified and directed |
| 7 | M&L for rendering 10mm thick on fair faces of concrete in ceiling in cement mortar 1:4,to be finished even andsmooth (without using extracement complete all as specified and directed |
| 8 | M&L for preparation of newly plastered surfaces and 3 coats of white wash onsurfaces of walls complete all as specified and as direcetd. |
| 9 | M&L preparation of newly plastered surfaces of walls including cornices and applying two coats of cement based paint over a coat of chalk whiting primer with using of all scaffolding,trestles,ladders,cradles which are necessary for execution of work and protective measuresincluding cleaning glass,joinery,electric fitting,wiring etc of drops and splashes and leaving premise,clean and tidy all asspecified & directed by the Engr-in-Charge. |
| 10 | Excavation in post holes each n.exc 0.50 cum getting out. Returning filling in layers n.exc 25cm etc removal at surplus soil to a distance n.exc 50 mt and making good surface in hard/ dense soil |
| 11 | M&L Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) laid in base, mass concrete all as specified and directed by Engineer In charge. |
| 12 | S&F Steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, MS Plate for fencing posts etc. cut to ordinary lengths |
| 13 | Material & labour for Flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe- 290(Gde E 165) Complete all as specified and as directed |
| 14 | Supply only Chain link of MS galvanised fencing any size or type Complete all as specified and as directed |
| 15 | Fixing onlychain link fencingincluding line wires, any mesh, size and type to any type ofstandard, rails, straining bolts etc., including provision of binding wire Complete all as specified and as directed |
| 16 | Material & labour for Mild steel round bars 10 mm dia and over,cut to length, bent to required shape including cranking, hooking ends and securing with welding with 10 cm overlaping between two bar all as specified and directed by Engineer-in Charge as in in reinforcement. |
| 17 | Supply & fix mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n exc 10cm long and dia of neck 11 to 15mm Complete all as specified and as directed |
| 18 | S & Fin repair Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 90mm to 110mm spacing and straing and fixing to any type of standard rails straining bolts, incluing securing or typing a crossings with an provision of galvanize mild steel wire, staples or steel pins, etc all as directed (each line wire to be measured) in repairs completed all as specified and as directed |
| 19 | M&L for two coats of synthetic enamel paint over a coat of red oxide zinc chrome on new steel surfaces of any description complete all as specified. |
| 20 | M&L Hardcore of gauge nexc 63mm, deposited, spread and levelled in layers n. exc 15cm thick, watered and rammed to surface complete all as directed. |
| 21 | Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cemrent mortar 1:4 complete all as specified and as direcetd. |
| 22 | M&L 75mm thick Plain Cement concrete type B-1, 1:2:4 (20mm graded aggregate) Laid in base of flooring as specified and directed by Engineer In charge. |
| 23 | M&L Cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75mm thick in floors and pavings etc. all as specified and directed. |
| 24 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil |
| 25 | Taking down Chowkhats or frames withshutters exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and as direcetd. |
| 26 | Taking down Chowkhats or frames withshutters n exc 1.5 sq. meach complete all as specified and as directed |
| 27 | Supply and fix solid PVC door frame of size 50 mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification complete all as specified and as directed by the Engineer-in-Charge |
| 28 | Supply and fix Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawingcomplete all as specified and as directed by the Engineer-in-Charge |
| 29 | S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 butt hinges for PVC door frame complete all as specified and as directed by the Engineer-in-Charge |
| 30 | Supply and fix 150 mm size Alluminium,anodised barrel tower boltsof extruted section and fixed complete all as specified and as directed by the Engineer-in-Charge |
| 31 | Supply and fix 150 mm size extruded aluminiumdoor handlesfabricated type complete all as specified and as directed by the Engineer-in-Charge |
| 32 | Removing demolished material / rubbishexc.1.50km and depositing wheredirected at a level n exc 5 km above the starting point |
| 33 | S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 34 | M&L for Preparing New wood and wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and asdirected by the Engineer-in-Charge. |
| 35 | M&L Complete removal of existing treatment on walls complete all as directed. |
| 36 | M&L for 2 coats of Oil bound distempering over a coat of primer over 3mm thick wall putty withwhite or tinted on walls complete all as specified and as directed. |
| 37 | M&L 2 coats of Cement Base Paintover a coat of primer on oldprepared surfaces of walls complete all as specified and as directed. |
| 38 | M&L 2 coats of white washon old plasteredsurfaces on ceilings complete all as specified and as directed. |
| 39 | S&F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified and directed. |
| 40 | S&F 35mm of 2nd class HW rail and style Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003(Part I), kiln seasoned and chemically pressure treated all as specified and directed by Engr-in-charge. |
| 41 | M&L Machine cut kota stone slab in stairs/ flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and including 15 mm thick screed bed/bedding layer in CM (1:6) complete all as specified and as directed. |
| 42 | M&L Kota stone slab 20-25mm thick in skirting, dado and pillar laid over cement screed and including 15 mm thick screed bed/bedding layer in CM (1:6) complete all as specified and as directed. |
| 43 | S&F Powder coated Aluminium frame for doors,windows/ Louvered and partitions with one or more rebatesincluding cleat for fixing etc including powder coating of any colour (min thickness of powder coating 50 micron) complete all as specified and directed by Engr-in-charge. |
| 44 | Supply and fix Powder coated Aluminium window shutters, sliding typeThreetrack including frame for fixing glass sections of aluminium section weighing 0.55 kg/Rm including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium snap beading, screws, anodised aluminium fittings such as handles and locking arrangement complete all as specified and as directed.Note : Glass and wire cloth will be measured and paid separately under relevant item.complete all as specified and as directed. |
| 45 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average with of aperture 1.4 0 mm and fixed with stainless steel wire staples complete all as specified and asdirected by the Engineer-in-Charge. |
| 46 | S&F 5.5 mm thick tinted glass of superior quality fixed to aluminium partition and door each pan. |
| 47 | M&L 50mm sand filling under floor including watering and consolidation all as specified and directed. |
| 48 | M&L Machine pressed precast conctete interlocking paver blockwith grey cement and colour pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 all as specified and directed. |
| 49 | M&L Providing, cement concrete in roof kerbs or mud stops, rounded 1:2:4 type B0 using 12.5mm graded stone aggregate or all as specified and directed. |
| 50 | M&L for loose filling with aggregate of gauge 40 to 50 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick to a true surface of transformer and two pole / four polestructure complete all as specified and as directed. |
| 51 | Supply and laying of sand Stone kerb of roughly squared stones of size 20cm x 30cm, all surfaces hammer dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 20mm jointed in cement mortar 1:6 and struck flush complete all as specified and directed. |
| 52 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
| 53 | Supply and fixing in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including provision of mounting pole of suitable dia and height complete all as specified and directed. |
| 54 | Supply and fixing in repair of Bamboo LED bollard lights 8 watt 230 Volts AC outdoor type aluminium landscape IP 65 luminiare for diffused lighting with high power LED as light source complete with driver including PCC structure for provision for mounting fitting of suitable dia and height complete all as specified and directed.Make : |
| 55 | Supply and fixing in repair of LED Post top lanterns of 45 Wattage aesthitically designed aluminium landscape and heat sink for thermal management IP66 protection luminaire powered by built in, isolated electronic LED driver in metal housing mounted on pole mounting suitable for 76 mm fixed on PCC block including of accessories for fixing complete all as specified and directed by Engr-in-charge. Make : Bajaj FLORENCE or Havells SAPPHIRE equivalent of Crompton or Wipro |
| 56 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 4 sq. mm nominal cross section in service connections complete all as specified and directed. |
| 57 | Supply and laying Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc of size 25mm dia complete all as specified and directed. |
| 58 | Supply and fixing for 40mm dia bore tubes, \"light grade\" galvanised, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fix in repairLED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp. complete all as specified and directed by Engineer-in-Charge. Make :- Havells/Bajaj/CG/ Philips. |
| 60 | Supply and fix in repairLED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp. complete all as specified and directed by Engineer-in-Charge. Make :- Havells/Bajaj/CG/ Philips. |
| 61 | Suply and fix in replacement ofMS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using pcc & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete |
| 62 | M&L for Earthing in replacement complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead strip 32x6 mmsize upto 7.5 mtr long in single length by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation in hard/dense soil and earth work GI pipe 20mm dia mediumj grade for watering and GI 40mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and as directed. |
| 63 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type |
| 64 | All as per Ser Item No. 63 here in before but for cable of size 70 to 95 sq mm. |
| 65 | All as per Ser Item No. 63 here in before but for cable of size 120 to 150 sq mm. |
| 66 | All as per Ser Item No. 63 here in before but for cable of size 185 to 240 sq mm. |
| 67 | M&L in repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing as required 32 X 6mm size galvanised steel strip complete all as specified and as directed. |
| 68 | Supply and fixing of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge. |
| 69 | Supply, installation, commissioning and testing in replacement of float cum boost SCR controlled 110 volt 25 Amps single phase 8 feeder Battery charger and D.C. Distribution Board in a Common Cubicle. The Charger is suitable for 230V +/-10%, AC Input and the Output is suitable to Charge of 24V/110VDC 100AH Batteries and also supply Load. The Output Voltage remains constant within +/- 2 % for AC Input Voltage variation 230V +/- 10% and Load variation 0-100 %. CURRENT RATING: 25.0A(ii) Supply and fixing of three core 4 sqmm PVC insulated FRLS copper cables - 90 RM (iii) Supply, install and commissioning Sealed Maintenance Free VRLA Battery Bank 110Volt. 100AH consisting of 55Nos. Cell of 02Volt each complete with Inter-cell cooper connector, SS Nut Bolt, MS Powder coated stand in factory charged condition |
| 70 | S&F Double legged informatory sign board as double side fixed on single frame and meeting back to back on square SS304 pipe. The boards shall be high intensitive grade retro reflective sheeting (AVERY DENNISON) of Blue or any approved colour as per IRC standards complete all as specified and directed.Note:- A. The Boards shall be made of Alco bond sheet as required size of 5.6 mtr X 1.2 mtr. Retro reflective sheeting is fixed on this Alco bond sheets with suitable adhesive. The letter writing (as directed) is done with computerised cut machine and fixed on this retro reflective sheeting. This board is mounted on the SS304 frame and fixed on the frame with POP revets.B. For double sided board two such boards made of Alco Bond sheets fixed on the single frame with back to back and should be mounted with POP revetsC. Fixing of board incl all fixing arrangement deemed to be included in this item.D. Letter writing (size, Nos of letters, colour etc) will be decided and directed by Engr-in-chargeE. Rate shall include one measurement for double side back to back F. Supplying and fixing of SS304 pipe for mounting board of suitable dia and height (not less than 3.5mtr from floor level) shall be included in above rateG. LED lighting arrangement as directed shall be included in above quoted rate. |
| 71 | S&F Double legged informatory sign board as double side fixed on single frame and meeting back to back on square SS304 pipe. The boards shall be high intensitive grade retro reflective sheeting (AVERY DENNISON) of Green / Blue or any approved colour as per IRC standards complete all as specified and directed.Note:- A. The Boards shall be made of Alco bond sheet as required size of 1.5 mtr X 1.2 mtr. Retro reflective sheeting is fixed on this Alco bond sheets with suitable adhesive. The letter writing (as directed) is done with computerised cut machine and fixed on this retro reflective sheeting. This board is mounted on the SS304 frame and fixed on the frame with POP revets.B. For double sided board two such boards made of Alco Bond sheets fixed on the single frame with back to back and should be mounted with POP revetsC. Fixing of board incl all fixing arrangement deemed to be included in this item.D. Letter writing (size, Nos of letters, colour etc) will be decided and directed by Engr-in-chargeE. Rate shall include one measurement for double side back to backF. LED lighting arrangement as directed shall be included in above quoted rate.G. Supplying and fixing of SS304 pipe for mounting board of suitable dia and height (not less than 3.5mtr from floor level) shall be included in above rate |
| 72 | Supply, laying, testing and commissioning of LT XLPE insulated strip armoured multi stranded aluminium underground cable of 16 Sqmm 4 core in trenches or fixed on pole/wall or drawn through pipes including suitable size of Lugs & Glands etc complete all as specified and directed by Engineer-in-Charge. |
| 73 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply and spread clean river sandin trenches for cushioning of cable complete all as specified and directed by Engineer-in-Charge.Note: Punned down thickness only shall be measured for the purpose of payment |
| 75 | Supply and lay un-reinforced precast concrete cable cover , class LV , Type Iflat size 250 x 150x 40 mm laid dry in treches over under ground cables complete all as specified and directed |
| 76 | Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge. |
| 77 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 78 | S&FOctagonal shaped GI hot dipped electric pole, Polished finished (7 metre long)complete with PCC base, bolts, nuts, washers, base plaes alongwith suitable size of Flexiable conduit as reqd length all as specified including the following:-(a) Excavation in post hole not exceeding for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole infoundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres.(b) M&L for Providing RCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation as per manufacturers design upto GL including Nuts, bolts, washers and base plates of suitable size and length for grouting in as per manufacturer\"s design.(c) Inbuilt internal junction box consists of incomer of MCB TPN 32 Amp 10 KA and alluminium busbar 16 Amp 04 Nos fixed on epoxy insulated pole and internal wiring complete |
| 79 | Supply and fix in repairLED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed by Engineer-in-Charge. |
| 80 | Dismantling of PCC Poles of any size, type, make complete all as specified and directed. |