| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed. |
| 3 | Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 4 | M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments. |
| 5 | M&L for brickslaid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed. |
| 6 | Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site complete all as specified and as directed.Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule.(2) Excvation and earth work shall be measured and paid seperately. |
| 7 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe including taking down complete all as specified and as directed. |
| 8 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe including taking down complete all as specified and as directed. |
| 9 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe including taking down complete all as specified and as directed. |
| 10 | S&F in repairs 25 mm dia, rigid non metalic, PVC Conduits complete with all accessories suitable for wiring to street lights complete all as specified and as directed. |
| 11 | S&F service cable, 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanisedsteel wire or tape and overall PVC sheathed 2 core stranded conductor of 6 Sqmm nominal cross sectional area complete all as specified and as directed. |
| 12 | S&F service cable, PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanisedsteel wire or tape and overall PVC sheathed 2 core stranded conductor of 4 Sqmm nominal cross sectional area complete all as specified and as directed. |
| 13 | S&F single run service cable with PVC insulated, stranded copper conductor served with an inner seathing of FRLSH suitable for outdoor uses and PVC sheathed 3 core stranded conductor of 2.5 Sqmm nominal cross sectional area complete all as specified and as directed. |
| 14 | Taking down LED/CFL/sodium vapour/metal halide/MV lampstreet light/flood light/ any other light fitting of any make and sizerefixing the same in position after replacement of unserviceable/defective parts likefittings , lamps , LED driver etc as required to make the fittings in smooth serviceable condition and testing complete and as directed. Note : (i) Replacement of unserviceable parts shall be measured and paid seperately as \"supply only\" (ii) Replacement of worn out cables as per existing size and type of the fitting shall be deemed to be included in the unit quoted rate of this item.(iii) Necessary climbing arrangements like scaffolding for repairing/ removing/ refixing the fittings should be included in the quoted rate. |
| 15 | All as per item No. 14 here-in-above but for hanger lights/flood lights/ street lights. |
| 16 | All as per item No. 14 here-in-above but for aviation lights. |
| 17 | S&F in repairs lamp holder assembly as per existing garden light fitting with necessary modifying the electrical connections complete all as specified and as directed. |
| 18 | S&Fin repair new LED street light fitting of capacity 90W, Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . |
| 19 | S&Fin repair for new LED street light fitting of capacity 70W,Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 1.5 Sqmm as required in existing location complete all as specified and as directed. . |
| 20 | S&Fin repair new LED street light fitting of capacity 60W, Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 1.5 Sqmm as required in existing location complete all as specified and as directed. . |
| 21 | S&F in repairs modular junction box made of SMC/FRPof size 350x250x150mm with provision of MCB SP, and connector terminal 4 pole indicating RYB Phase Colour and Neutralcolour complete fixedto street light pole with suitable sizeofmild steel/ flat iron clamps, nuts and bolts complete all as specified and as directed. |
| 22 | S&F in repairs, LED post top lantern of 40 WattMAPLE Decorative Post top for 360° indirect light with IP 65 protection. Resistant to impact and corrosion. Glare-free and better uniformity including providing and connection with 1.5Sqmm copper conductor, multistranded copper conductor cable of required length complete all as specified andas directed. |
| 23 | S&F in repairs decorative gate light 20W made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 Base, including providing and connection with 2.5 Sqmm aluminium conductor, cable of required length and taking down old unserviceable fitting of any make and size complete all as specified and as directed. |
| 24 | S&F 10W LED Bollard MAYA I Pressure die cast powder coated housing with PC diffuser. Efficient high output LED with IP65 protection complete all as specified and directed . |
| 25 | S&F in repairs street light bracket arm of length not less than 1.5 m made out of GI tubing, 40mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed. |
| 26 | S&F LED post top 20watts cap HERITAGERated LED Post Top ideal to light up parks, gardens and heritage sitewith rated voltage 240 Volts including high voltage and short circuit protection IP 65,with necessary suitable fixing accessories/arrangements complete all as specified and as directed. |
| 27 | S&F in repair of power contactor 3 pole 65 Amps all as specified and directed. |
| 28 | Supply only Integral LED aviation lights comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. |
| 29 | S&F in repairs LED lamp10 Watt B22 Base surge protection 2.5K,CCT 6500K complete all as specified and as directed. |
| 30 | S&F in repairs LED lamp14 Watt B22 Base surge protection 2.5K,CCT 6500Kcomplete all as specified and as directed. |
| 31 | S&F in repairsLED lamp20 Watt B22 Base surge protection 2.5K ,CCT 6500K complete all as specified and as directed. |
| 32 | S&F in repairs PVC insulation tape of pack of 30 rolls multi colour and black of standardsize and thickness 2 to 3mm complete all as specified and as directed. |
| 33 | S&F in repairs LED drivers suitable for any make and type of LED street light fittings of capacity 20 to 45 watt including taking down old unserviceable driver complete all as specified and as directed. |
| 34 | S&F in repairs LED drivers suitable for any make and type of LED street light fittings of capacity 60 to 120 watt including taking down old unserviceable driver complete all as specified and as directed. |
| 35 | S&F in repairs LED drivers suitable for any make and type of LED Flood light fittings of capacity 50 to 150 watt including taking down old unserviceable driver complete all as specified and as directed. |
| 36 | S&F in repairs LED drivers suitable for any make and type of LED Flood light fittings of capacity 200 watt including taking down old unserviceable driver complete all as specified and as directed. |
| 37 | M&L for scrapping the existing surfaces of the street light poles of height upto 11 metres (painting length) with emery paper, removing the dust and rustproperly and applying 2 coats of aluminum paint over complete pole and stickering the pole with glow sign round the electrical pole at three places of 10cm width andnumbering with paint not less than 4 letters with glow sign material at the bottom of pole and nomenclature shall be given by Engineer-in-Charge complete all as specified and as directed. |
| 38 | Taking down the service connections of the lighti fittings from connector/ ceiling roses/ overhead bare conductor etc of the street/ security lights , fromheight of approx 7mtr above groundby any means on PCC/Metal poles with all safety measures to remove the carbon deposits/ disconnected due to wind/wear & tear complete and connecting /fixing back by using PVC connectors connections/fittings at existing place complete all as specified and as directed |
| 39 | Taking down carefully 15 meter long high Mast light,removing all the serviceable fittings (6/9 Nos) of 250/400 W for refixing after replacement of worn and unservicebleRope,Chain, Gear ,Jubli Clamp etc .After servicing Re-Installation of the complete High Mast complete all as specified and directed. Note- Spare parts shall be measured and paid seprately under relevant items. |
| 40 | M&L for opening / removing of burnt out winding and complete with new winding for 1 HP Motar for automatic operation of the High mast ,after re-installation and testing complete all as specified and directed. |
| 41 | Disconnecting LT street light UG Cable from juction box ,digging the cable to take out the loop after Excavation ,fresh & checking the cable and fix the lugs of suitable size and connect the cable with junction box complete all as specified and directed by Engr-In -Charge.(a) Excvation and earth work shall be measured and paid seperately. |
| 42 | S&F in repair LED tricolour strip light flexible type of length 18 mtrcomplete all as directed. |