Tender For Various Defects On Engineering Defects => Limited

Issued by Government Departments · porbandar, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Jan 2026
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
porbandar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Various Defects On Engineering Defects => Limited; 1 Various defects on enggineering equipment. 2 E-904:Following valves of various system not holding due to worn out spindle & seat. Valves to be overhauled and pressure tested up to 10 bar. In way job includes removal and fitment of valves. Ser Description Size Qty1.Fwd Port tank inlet Gate valve40 mm 01 No. 2.Fire main gate valve80 mm 02 No.3.FER fireman supply SDNR valve65 mm 02 No. 3 E-905:Fire & sprinkling pump priming unit ball valve not holding. Same to be renewed along with adaptor as per sample. (Qty-02 Nos.) 4 E-906:Leakage and abnormal noise observed from Stbd WHR pump. Suspect mechanical seal and bearing worn out. Pump to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of pump 5 E-907:DA No.1 sea chest strainer change over unit stuck in position. Same to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of unit. 6 E-908:Motor driven diving air compressor not developing sufficient pressure due to defective safety valve. Same to be renewed/ repaired as per sample. (Qty-01 no., Set pressure-330 bar) 7 E-909: Fwd HP air compressor not developing sufficient pressure. Suspect loader/unloader mechanism and solenoid valve malfunctioning. DI/DR to be carried out andproved for satisfactory operation. 8 E-910:Defueling point flange at quarter deck observed deteriorated. Same to be fabricated as per sample (Mat:-MS, Qty:02 Nos.) 9 E-911: AVCAT fuel leakage observed from AVCAT system pipeline due to worn out pipeline thread. Leakage to be arrested by threading on pipeline and proved for satisfactory operation. In way job includes removal and fitment of pipeline. 10 E-912: Lub oil leakage observed from lub oil filter assembly on DA no. 2 due to worn out internal thread of filter assembly. Leakage to be arrested by threading on assembly. In way job includes removal and fitment of filter assembly and associated system.

BOQ

Name of Work: Various defects on engineering defects
Sl. No. Item Description
1Various defects on enggineering equipment.
2E-904:Following valves of various system not holding due to worn out spindle & seat. Valves to be overhauled and pressure tested up to 10 bar. In way job includes removal and fitment of valves. Ser Description Size Qty1.Fwd Port tank inlet Gate valve40 mm 01 No. 2.Fire main gate valve80 mm 02 No.3.FER fireman supply SDNR valve65 mm 02 No.
3E-905:Fire & sprinkling pump priming unit ball valve not holding. Same to be renewed along with adaptor as per sample. (Qty-02 Nos.)
4E-906:Leakage and abnormal noise observed from Stbd WHR pump. Suspect mechanical seal and bearing worn out. Pump to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of pump
5E-907:DA No.1 sea chest strainer change over unit stuck in position. Same to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of unit.
6E-908:Motor driven diving air compressor not developing sufficient pressure due to defective safety valve. Same to be renewed/ repaired as per sample. (Qty-01 no., Set pressure-330 bar)
7E-909: Fwd HP air compressor not developing sufficient pressure. Suspect loader/unloader mechanism and solenoid valve malfunctioning. DI/DR to be carried out andproved for satisfactory operation.
8E-910:Defueling point flange at quarter deck observed deteriorated. Same to be fabricated as per sample (Mat:-MS, Qty:02 Nos.)
9E-911: AVCAT fuel leakage observed from AVCAT system pipeline due to worn out pipeline thread. Leakage to be arrested by threading on pipeline and proved for satisfactory operation. In way job includes removal and fitment of pipeline.
10E-912: Lub oil leakage observed from lub oil filter assembly on DA no. 2 due to worn out internal thread of filter assembly. Leakage to be arrested by threading on assembly. In way job includes removal and fitment of filter assembly and associated system.

AI Tender Summary

OUR REF NO 53584882
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-01-2026
Authority
Authority Name Indian Coast Guard
Work Description Tender For Various Defects On Engineering Defects => Limited; 1 Various defects on enggineering equipment. 2 E-904:Following valves of various system not holding due to worn out spindle & seat. Valves to be overhauled and pressure tested up to 10 bar. In way job includes removal and fitment of valves. Ser Description Size Qty1.Fwd Port tank inlet Gate valve40 mm 01 No. 2.Fire main gate valve80 mm 02 No.3.FER fireman supply SDNR valve65 mm 02 No. 3 E-905:Fire & sprinkling pump priming unit ball valve not holding. Same to be renewed along with adaptor as per sample. (Qty-02 Nos.) 4 E-906:Leakage and abnormal noise observed from Stbd WHR pump. Suspect mechanical seal and bearing worn out. Pump to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of pump 5 E-907:DA No.1 sea chest strainer change over unit stuck in position. Same to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of unit. 6 E-908:Motor driven diving air compressor not developing sufficient pressure due to defective safety valve. Same to be renewed/ repaired as per sample. (Qty-01 no., Set pressure-330 bar) 7 E-909: Fwd HP air compressor not developing sufficient pressure. Suspect loader/unloader mechanism and solenoid valve malfunctioning. DI/DR to be carried out andproved for satisfactory operation. 8 E-910:Defueling point flange at quarter deck observed deteriorated. Same to be fabricated as per sample (Mat:-MS, Qty:02 Nos.) 9 E-911: AVCAT fuel leakage observed from AVCAT system pipeline due to worn out pipeline thread. Leakage to be arrested by threading on pipeline and proved for satisfactory operation. In way job includes removal and fitment of pipeline. 10 E-912: Lub oil leakage observed from lub oil filter assembly on DA no. 2 due to worn out internal thread of filter assembly. Leakage to be arrested by threading on assembly. In way job includes removal and fitment of filter assembly and associated system.
Basic Detail
Tender No 344/40/EN/STK/2025-26
Bidding Type Tender
Location
City porbandar
State Gujarat
Key Dates
Publish Date 21 Jan 2026
Submission Date 27 Jan 2026
Open Date 28 Jan 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
31bb0689-117e-483b-be32-fa7eaf706b1b.html
BOQ_839405.xls
RFP.PDF
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

31bb0689-117e-483b-be32-fa7eaf706b1b.html

xls

BOQ_839405.xls

PDF

RFP.PDF

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender