| 1 | Supply, Install , Testing and Commissioning Hi-wall SPLIT AC INVERTER TYPE,4 -in-1 adustable mode with stabilizer indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating and of Capacity 2.0 TR complete all as specified and directed by Engineer-in-Charge . |
| 2 | All as per item No. 01 here-in-before but capacity 1.5 TR |
| 3 | All as per item No. 01 here-in-before but capacity 1 TR |
| 4 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 corecomplete all as specified and directed by Engineer-in-Charge . |
| 5 | S&F in replacement vertical type DB ,double door (VTPN) suitable for and includingEarth and neutral bus bar of capacity upto 40 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and boltincluding matching the existing surfaceall as specified and directed by Engineer-in-Charge . |
| 6 | M&L for sub main wiring drawing through PVC casing and capping with two single core 16 sq mm and one run of 6 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed by Engineer-in-Charge. Note :- Three run of 16 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 7 | M&L for sub main wiring drawing through PVC casing and capping with two single core 10 sq mm and one run of 10 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed by Engineer-in-Charge. Note :- Three run of 10 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 8 | M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed by Engineer-in-Charge. Note :- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 9 | Supply and fixing MCCB 3 Pole , 415 V, Adjustable type,160 Amps with breaking capacity 36 KA complete with connection testing and commissioning. |
| 10 | Supply and fixing MCCB 3 Pole , 415 V, Adjustable type,125 Amps with breaking capacity 16 KA complete with connection testing and commissioning. |
| 11 | S&FDistribution Board, 4 Way ,(TPN) ,Double door complete all as specified and as directed by Engineer-in-Charge. Cat part No. 811807[Optipro] of Indo Asian and equivelent toStandard / Havells |
| 12 | S&FDistribution Board, 12 Way ,(SPN) ,Double door complete all as specified and as directed by Engineer-in-Charge.Cat part No. 811807[Optipro] of Indo Asian and equivelent toStandard / Havells |
| 13 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of TP 40A capacity in the DB complete with connection testing and commissioning. |
| 14 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of TPN/FP 40A capacity in the DB complete with connection testing and commissioning. |
| 15 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of TPN 32A capacity in the DB complete with connection testing and commissioning. |
| 16 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 20A current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 17 | Supply and fixing 20 Amps SPN MCB with metallic Plug & Socket with MCB and steel enclosure.Model No.DBOXx MCB Protected unit. |