| 1 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sq mm 3.5 core including taking out old unsv cable any type complete all as specified and directed. |
| 2 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core including taking out old unsv cable any type complete all as specified and directed. |
| 3 | S & F intrench in replacement GItubing light grade for road crossing and cable protection of the 80 mm dia complete all as specified and directed. |
| 4 | Taking out old unsv panel any type and supply & fix Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board indoor type, platform mounted including taking out old unsv, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable of adequate size but not less than 2.5 Sqmm. The scope of work includes the following :- |
| 5 | INCOMING:-(i) MCCB 4 Pole 415 volts grade 125 Amps rating and 25 KA rupturing capacity - 01 No (ii)Voltmeter 0-500 volts,96 square mm, flnsh pattern with 3 way rotary selector switch-01 No(iii) Ammeter size 96 square mm, dial flush pattern having dual range 0-250 Amps with three way rotary selector switch -01 No(iv) Suitable CTsas per load ratio, ISI marked - 01 set of three (v)LED Indicating lamp-01 set of three(vi)Phase sequence corrector of suitable range-01 no |
| 6 | OUTGOING:-(i)MCCB 4 Pole, 415 volts grade 100 Amps rating and 16 KA rupturing capacity -02 Nos (1xstandby)(ii)MCB TPN, 415 volts grade 40 Amps rating- 01 No(iii)MCB SPN, 415 volts grade 10 Amps rating- 02 Nos(iv)MCB SP, 415 volts grade 06 Amps rating- 02 Nos(v) 50 HP fully automatic Star Delta Starter - 02 Nos(vi) Motor protection relays 240VAC, 415V,32-88Amp rating capacity - 02 nos |
| 7 | Taking out old unsv panel any type and supply & fix Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board indoor type, platform mounted including taking out old unsv, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 1600 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable of adequate size but not less than 2.5 Sqmm. The scope of work includes the following :- |
| 8 | INCOMING:-(i)4 Pole ACB with Microprocessor Release IPR 1+ grade 1000 Amps rating and 50 KA rupturing capacity - 01 No (ii)Digital Voltmeter 0-500 volts,(iii) Digital Ammeter 0-1000 Amps (iv) Suitable CTsas per load ratio, ISI marked - 01 set of three (v)LED Indicating lamp-01 set of three |
| 9 | OUTGOING:-(i)MCCB 4 Pole, 415 volts grade 630 Amps rating and 50 KA rupturing capacity -01 Nos(ii)MCCB 4 Pole, 415 volts grade 400 Amps rating and 36 KA rupturing capacity -02 Nos(iii)MCCB 4 Pole, 415 volts grade 160 Amps rating and 16 KA rupturing capacity -01 Nos(iv)MCB SPN, 415 volts grade 10 Amps rating- 02 Nos(v)MCB SP, 415 volts grade 06 Amps rating- 02 Nos |
| 10 | M&L in repair to make Glow sign board of size 10 feet x 2.5 feet in aluminum channel(25mmx25mm) with white acrilic sheet 2mm thick in front portion for lighting and remaining portion with 22 gauge GI plain sheet fixing with 4 nos LED tube light complete with electric wiring. The glow sign board containing blue colour computerized reflected letters all as specified and directed by Engr-in-Charge. Note:- (i) The glow sign board contained details and letter sizes to be as per sample given by Engr-in-Charge before making of sign board. (ii) Electric connection to be given from nearest existing panel with 1.5 Sqmm twin core flexible copper cable.(iii) Glow sign board to be made as per sample as directed by Engr-in-Charge. |
| 11 | M&L for Self reflective sign board of size 1200mm X 900 mm, made of 2 mm thick aluminium sheet, fixed in stainless steel frame with appropriate size of nuts, bolts and washers, with greencolour back ground and silver self reflected border and computerised self reflected letters on both side complete all as specified and directed.Note:-(i) Stainless steel frame, nuts, bolts, washers, and letters rates to be included by the tenderer.(ii) Sign board to be made as per sample as directed by Engr-in-Charge.(iii) Excavation,PCC & Iron wk shall be paid extra under relevant items. |
| 12 | S&F in replacement, motor protection relays 240VAC, 32-88Amp rating capacity inbuilt Overload,Locked Rotor, Single Phasing, Current Unbalance,Phase Sequence Reversal, Under Current,Inbuilt CT’s (1 A to 88 A), Trip indication, Test facility, Selectable trip class, complete taking out old unsv complete all as specified and directed. |
| 13 | M&L for replacement earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thickburied directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than1.5 meters below normal ground level, connected to the galvanised earth strip32 x 6 mm by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel using GI including PCC (concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm) 8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part-I and specified including provision of earth wire/ strip protected by 40 mm dia medium grade GI pipe including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc and testing on complete, complete all as specified and directed Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised iron strip 32X6 mm and protection pipe of 40mm bore medium grade, GI light grade 20mm bore watering pipe. |
| 14 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations,laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in Soft/loose soil, complete all as specified and directed. |
| 15 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm.in hard/dense soil complete all as specified and directed. |
| 16 | Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 17 | Supply and laying of burnt clay of fly ash building bricks, designnation 75 (Kg/cm2) laid flat in trenches for cable protection with wide equal to length of brick, complete all as specified and directed |
| 18 | M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1Note:-Sand shall be fine sand as specified for plastering. |
| 19 | Supply and fixing MCCB, 4 pole, 160 Amps, Icu=25KA, 415 volts, 50 hz, AC ,with fixed thermal and magnetic release duly connected with copper spreader links and proper size of lugs, nuts, bolts and washers complete with taking down old unserviceable MCB complete all as specified and directed. |
| 20 | Supply and fixing MCCB, 4 pole, 200 Amps, Icu=25KA, 415 volts, 50 hz, AC ,with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers complete with taking down old unserviceable MCB complete all as specified and directed. |
| 21 | Supply and fixing MCCB, 4 pole, 250 Amps, Icu=36KA, 415 volts, 50 hz, AC ,with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers complete with taking down old unserviceable MCB complete all as specified and directed. |
| 22 | Supply and fixing in replacement MCCB, 4 pole, 400 Amps, Icu=36KA, 415 volts, 50 hz, AC ,with fixed thermal and magnetic release duly connected with copper spreader links and proper size of lugs, nuts, bolts and washers complete with taking down old unserviceable all as specified and directed. |
| 23 | Supply and fixing in replacement of fully automatic, 3 phase Star delta starter with enclosure suitable for motor upto 50 HP capacity including connector & cables required complete all as specified and directed. |
| 24 | Supply and fixing in replacement of fully automatic ,3 phase Star delta starter with enclosure suitable for motor upto 75HP capacity including connector & cables complete all as specified and directed. |
| 25 | Supply & fixing in replacement Single phase preventor for motor protection with by pass arrangements to run the motor in case of emergency withincluding taking out of unserviceableof any make and type complete all as specified and directed. |
| 26 | S&F in replacement 100 Amps, 415V, 4 pole off Load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers, including taking out old unsv complete all as specified and directed . |
| 27 | S&F in replacement 200 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers, including taking out old unsv complete all as specified and directed . |
| 28 | S&F in replacement 400 Amps, 415V, 4 pole ON load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers, including taking out old unsv complete all as specified and directed . |
| 29 | S&F in replacement 630 Amps, 415V, 4 pole ON load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers, including taking out old unsv complete all as specified and directed . |
| 30 | M&L for dismantiling electric motor of capacity above22.5 HP and upto 50 HP,3 phase, 400/ 415 volts, 50 Hz of anymake / typecarefully from foundation after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling complete. |
| 31 | M&L for assessing the repairs to be carried out to themotor of capacity above22.5 HP upto 50 HP, 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make.after dismantling and carrying out the neccessary repairs to motor by opening the electric motor carefully removing all burnt wire , cleaning the slots thoroughly and rewinding the motor with super enamelled copper wire of existing size including, PVC sleeve , insulation tape , mika paper, varnishing two coats, drying and reassembling the electric motor at site complete withtesting forsmooth running of the motor on full load for 08 hours continuouslyall as directed at site.Note: Payment of bearing shall be made separately as \"supply only\"under relevant items. |
| 32 | M&L for Lifting of electric motor 20 HP to 75 HP capacity from existing position after disconnection of all electrical connection for renewal of unserviceable bearing , TT plate , top shaft and applyinggreasing to all movable parts, re-installing at siteand reconnecting all electrical connection including testing with the satisfection of Engr-in- Charge.Note : (a)Necessary payment for bearing, TT plate and Top Shaftshall be measured and paid separately under relevant items if required at site. (b)Quoted rate deemed to include cost of grease as required at site. (c)The contractor shall lift the motors as directed by the dept for normal servicing even if no repairs are reqd for the motor. |
| 33 | Supply only Thrust ball bearing No.6311 of existing make , suitable for vertical hellow shaftmotor ofcapacity 50 HP,complete all as specified and directed |
| 34 | Supply only Thrust ball bearing No.6316 of existing make , suitable for vertical hellow shaftmotor ofcapacity 50 HP,complete all as specified and directed |
| 35 | Renewal of ball bearing sheet suitable for motor of capacity20 HP to 75 HP motor including lathe work as required at site complete all as specified and directed. |
| 36 | M&L for Lifting/Dismantling carefully turbine pump set bowl assembly of any make, capacity upto 50000 GPHcomplete with out damaging any parts of the pump and setting a side in pump house for ascertaining the serviceability of existing parts with the following :-(a) Thoroughly dismantling and cleaning of complete bowl assembly items such as CI bowls, impeller, lock collets, bowl bush, suction and discharge case with GM bush including pump shaft. (b) Cleaning of all rotary and stationary parts of pump bowl assembly and making them for their satisfactory run.(c) Re-assembling the complete bowl assembly pump with all existing serviceableparts and renew the worn out unserviceable parts including lathe work and balancing of assembly others small nature of indispensable items as required for repairing.Note :-Parts renewed shall be measured and paid for separately under respective item of Schedule \"A\"/BoQ at supplied only rates. Cost of labour for fixing of new parts shall be deemed to include in the rate quoted by tenderer. |
| 37 | Supply only Cast ironbowl assembly centrifugally cast complete with gun metal bush ( Make as per OEM) for pump of capacity up to 50000 GPH of vertical turbine pump . |
| 38 | Supply only Gun metal impeller ( Make as per OEM )for vertical turbine pump of capacity up to 50000 GPH of any type. |
| 39 | Supply only Stainless steel non magnetic pump shaft25 to 32 mm ( Make as per OEM ) dia suitable for 6 to 9 stage pumps (Bowl assembly) as directed . |
| 40 | Supply only Mild steel line shaft (bright) steel 25 to 32 mm dia 10 Ft long both ends threaded ( Make as per OEM ) complete all as specified and directed. |
| 41 | Supply only Shaft coupling / sleeve of high carbon steel for interlinking of size25 mm to 32 mm dia line shaft( Make as per OEM ) complete all aspecified and directed. |
| 42 | Supply only Gun metal bush for suction case of VT pump ( Make as per OEM ) complete all as specified and directed. |
| 43 | Supply only Cast iron guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia line shaft of 150 mm borepipe ( Make as per OEM ) all aspecified and directed. |
| 44 | Supply only Rubber packing for discharge head upto 200 mm bore complete all as specified ( Make as per OEM ) complete all aspecified and directed. |
| 45 | Supply only Stainless Steeltop shaft not exceeding 32 mm dia duly threaded both ends and made suitable slot for fixing the stainless steel key adjusting nut & lock, washer (Make as per OEM) complete all as specified and directed. |
| 46 | M&L for Lowering of turbine pump set any type and capacity upto 50000 GPH re-assembling of all accessories and column pipe after cleaning manuallyincluding fixing of motor in existing position making all Electrical & water supply connections and adjustment of pump load etc and testing of pump and motor after installation complete all as specified and directed. |
| 47 | M&L for Labour for lifting of submersible pumpalong with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etcafterdisconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation to market and back for repair complete all as specified & directed for 20 HP to 30 HP capacity pump set.Note: Parts Renewed and rewinding of motor shall be measured and paid separately. |
| 48 | Supply only Gunmetal impellers suitable for 20 to 30 HP Submersible pump |
| 49 | Supply only Gunmetal bush suitable for 20 to 30 HP Submersible pump |
| 50 | Supply only stainless steel sleeve suitable for 20 to 30 HP Submersible pump |
| 51 | Supply only \"C\" type bushes for impellers suitable for 20 to 30 HP Submersible pump |
| 52 | Supply only bowl case suitable for 20 to 30 HP Submersible pump |
| 53 | Supply only stainless steel pump shaft of suitable lengthcomplete in all respect suitable for 20 to 30 HP Submersible pump |
| 54 | M&L for Lowering downof submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 20 HPto 30 HP capacity pumpset. |
| 55 | M&L for rewinding of submersible motor electric driven , AC supply with PVC insulated copperwire (ISI marked) as per existing gauge,including connected works for rewinding .The scope of works includes dismantaling ,removal of old winding wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directedfor 30 HP Note: Other parts required for repair will be measued and paid for separately under respective sch item. |
| 56 | Supply only Gunmetal bush for submersible motor suitable for 20 to 30 HP. |
| 57 | Supply only Thurst bearing for submersible motor suitable for 20 to 30 HP. |
| 58 | Supply only SS shaft for motor of suitable size and length for submersible motor of capapcity 20 to 30 HP. |
| 59 | M & Lcement concrete type B-11:2:4 (20mm grade stone aggregate) as in door cills, path and plinth protection (of any section)including chambers, weatherings, throat-ing etc and setting in mortar complete all as specified and directed. |
| 60 | M&L for iron work as in angle/clamps/channel for branch connection of water supply, made to shape of flat iron of suitable size incl nuts, bolts, washers of appropriate size and painting with synthetic enamel paint in two coats over one coat of redoxide zinc chrome primer complete all as specified.Note:- Cost of fixing clamps/angle iron/frame in walls by cutting and grouting in PCC is deemed to include in the rate quoted by tenderer. |
| 61 | Supply & fix in repair, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board indoor type, platform mounted including taking out old unsv, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 300 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable of adequate size but not less than 2.5 Sqmm. The scope of work includes the following :- |
| 62 | INCOMING:-(i) MCCB 4 Pole 415 volts grade 160 Amps rating and 25 KA rupturing capacity - 01 No (ii)Voltmeter 0-500 volts,96 square mm, flnsh pattern with 3 way rotary selector switch-01 No(iii) Ammeter size 96 square mm, dial flush pattern having dual range 0-200 Amps with three way rotary selector switch -01 No(iv) Suitable CTsas per load ratio, ISI marked - 01 set of three (v)LED Indicating lamp-01 set of three(vi)Phase sequence corrector - 01 no |
| 63 | OUTGOING:-(i)MCCB 4 Pole, 415 volts grade 100 Amps rating and 16 KA rupturing capacity -02 Nos(ii)MCB TPN, 415 volts grade 40 Amps rating- 01 No(iii)MCB SPN, 415 volts grade 16 Amps rating- 01 Nos(iv)MCB SP, 415 volts grade 06 Amps rating- 02 Nos(v) 50 HP fully automatic Star Delta Starter - 02 Nos(v) 50 HP fully automatic Star Delta Starter - 02 Nos(vi) Motor protection relays 240VAC, 415V,32-88Amp rating capacity - 02 nos |
| 64 | Supply & fix taking out old unsv panel any type, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board indoor type, platform mounted including taking out old unsv, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable of adequate size but not less than 2.5 Sqmm. The scope of work includes the following :- |
| 65 | INCOMING:-(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 16 KA rupturing capacity - 01 No (ii)Voltmeter 0-500 volts,96 square mm, flnsh pattern with 3 way rotary selector switch-01 No(iii) Ammeter size 96 square mm, dial flush pattern having dual range 0-250 Amps with three way rotary selector switch -01 No(iv) Suitable CTsas per load ratio, ISI marked - 01 set of three (v)LED Indicating lamp-01 set of three(vi)Phase sequence corrector - 01 no |
| 66 | OUTGOING:-(i)MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity -02 Nos (1x Standby)(ii)MCB TPN, 415 volts grade 32 Amps rating- 01 No(iii)MCB SPN, 415 volts grade 16 Amps rating- 01 Nos(iv)MCB SP, 415 volts grade 06 Amps rating- 02 Nos(v) 40 HP fully automatic Star Delta Starter - 02 Nos(vi) Motor protection relays 240VAC, 415V,32-88Amp rating capacity - 02 nos |
| 67 | Supply & fix taking out old unsv panel any type, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board indoor type, platform mounted including taking out old unsv, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 400 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable of adequate size but not less than 2.5 Sqmm. The scope of work includes the following :- |
| 68 | INCOMING:-(i) MCCB 4 Pole 415 volts grade 200 Amps rating and 25 KA rupturing capacity - 01 No (ii)Voltmeter 0-500 volts,96 square mm, flnsh pattern with 3 way rotary selector switch-01 No(iii) Ammeter size 96 square mm, dial flush pattern having dual range 0-250 Amps with three way rotary selector switch -01 No(iv) Suitable CTsas per load ratio, ISI marked - 01 set of three (v)LED Indicating lamp-01 set of three(vi)Phase sequence corrector - 01 no |
| 69 | OUTGOING:-(i)MCCB 4 Pole, 415 volts grade 125 Amps rating and 25 KA rupturing capacity -02 Nos (1x Standby)(ii)MCB TPN, 415 volts grade 32 Amps rating- 01 No(iii)MCB SPN, 415 volts grade 16 Amps rating- 01 Nos(iv)MCB SP, 415 volts grade 06 Amps rating- 02 Nos(v) 40 HP fully automatic Star Delta Starter - 02 Nos |