| 1 | Supply & filling for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading lime stone powder under stones complete all as per specified and directed. |
| 2 | Supply and fix in repair CHAIN LINK FENCING OF SIZE 4 MM GI WIRE with post and door frame arrangement, for LT panels/two pole structure/four pole structure/etc of height 4 feetcompleteall as directed by Engineer-in-Charge |
| 3 | Taking down old unsv Prestressed Concrete LT pole and supply and erection of Prestressed Concrete LT pole 9.0 mtr long in true vertical position of size 102x172 mm at top and 102 x 279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black stripcomplete all as specified & directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. |
| 4 | Taking down old unsv Steel tubular LT pole and supply and erection of steel tubular swaged poles 9.0 mtr long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, providing synthetic enamel aluminium paint over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black stripcomplete all as specified & directed.Note:- (i) Earth work and PCC shall be measured and paid seperately. |
| 5 | Supply and fixing in replacement ofstay assembly complete with all accessories, such as stay plate 230x230x6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc all as per electrical plate No 1 or SSR part 1 and as directed incl taking down old unsv stay assycomplete all as specified & directed.Note- The quoted rate shall include the cost of loop type insulator, stay clamps, excavation, PCC, stay wire, stay bow, turn buckle, nuts etc. complete. |
| 6 | Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation all as specified and as directed. |
| 7 | Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay assembly and coping for poles including necessary form work to exposed surfaces finished smooth and even all as specified and as directed. |
| 8 | Material and labour for PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete allas specified and directed at site. |
| 9 | Material & Labour for painting of LTsteel tubular poles9 mtrs long including removing rusted particles painting withtwo coats of synthetic enamelaluminium paint over a coat of red oxide including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paintcomplete all as specified & directed. Note: (i)The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge.(ii)The quoted rates shall including the repairing of coping with cement / PCC if any |
| 10 | Material & Labour for painting of LT Prestressed Concrete pole 9 mtr longpainting with two coat of synthetic enamel paint also marking black & white strips alternatively 30 cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint including cross arms ,bracing,and other steel parts and repairing of and painting on coping with cement base white paintcomplete all as specified & directed. Note: (i)The quoted rate shall includes making of numbers on each LT pole as per direction of Engr-in-Charge.(ii)The quoted rates shall including the repairing of coping with cement / PCC |
| 11 | Material and labourfor spraying chemical (Round up) on area to remove unwanted vegitation/grass at various locationscomplete all as specified & directed. |
| 12 | Material & Labour in replacement of steel nuts, bolts, washers of any size required at site as specified and directed . |
| 13 | Repair to LT panel box/body by repalcing the damaged/rusted MS sheet/panel doors(front and back)/MCCB COVER PLATEof existing size and gauge fabricated cut to size of original length inclproviding hinges and other hard ware item like handless etc complete all as specified and directed . |
| 14 | Taking up or down 10 sqmm 2 core worn out/ damaged / partially serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors 1100 volt grade fromtrench including taking out unserviceable bricks,pipes etc testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable and keeping in safe custody the serviceable portion for reuse, stocking serviceable bricks for reuse complete all as specified and directed(Note: Earth work shall be measured and paid separately under relevant item of BoQ). |
| 15 | All as per item No. 14 here-in before but for cable of size 4 core 10 sqmm. |
| 16 | All as per item No. 14 here-in before but for cable of size 4 core 16 sqmm. |
| 17 | All as per item No. 14 here-in before but for cable of size 4 core 25 sqmm. |
| 18 | All as per item No. 14 here-in before but for cable of size 3.5 core 35 sqmm. |
| 19 | All as per item No. 14 here-in before but for cable of size 3.5core 50 sqmm. |
| 20 | All as per item No. 14 here-in before but for cable of size 3.5 core 70 sqmm. |
| 21 | All as per item No. 14 here-in before but for cable of size 3.5 core 95 sqmm. |
| 22 | All as per item No. 14 here-in before but cable of size 3.5 core 120 sqmm. |
| 23 | All as per item No. 14 here-in before but cable of size 3.5 core 150 sqmm. |
| 24 | All as per item No. 14 here-in before but cable of size 3.5 core 185 sqmm. |
| 25 | All as per item No. 14 here-in before but cable of size 3.5 core 240 sqmm. |
| 26 | All as per item No. 14 here-in before but cable of size 3.5 core 300 sqmm. |
| 27 | Supplying, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 300 Sq mmincluding taking down old unserviceable cable complete all as specified . |
| 28 | All as per item No.27 here in above but of size 3.5 core 240 Sqmm complete all as specified . |
| 29 | All as per item No.27 here in above but of size 3.5 core 185 Sqmm complete all as specified . |
| 30 | All as per item No.27 here in above but of size 3.5 core 150 Sqmm complete all as specified . |
| 31 | All as per item No.27 here in above but of size 3.5 core 120 Sqmm complete all as specified. |
| 32 | All as per item No.27 here in above but of size 3.5 core 95 Sqmm complete all as specified. |
| 33 | All as per item No.27 here in above but of size 3.5 core 70 Sqmm complete all as specified. |
| 34 | All as per item No.27 here in above but of size 3.5 core 50 Sqmm complete all as specified. |
| 35 | All as per item No.27 here in above but of size 3.5 core 35 Sqmm complete all as specified. |
| 36 | All as per item No.27 here in above but of size 4 core 25 Sqmm complete all as specified. |
| 37 | All as per item No.27 here in above but of size 4 core 16 Sqmm complete all as specified. |
| 38 | All as per item No 27 here in above but of size 4 core 10 Sqmm complete all as specified. |
| 39 | All as per item No.27 here in above but of size 2 core 10 Sqmm complete all as specified. |
| 40 | Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soilall as specified. |
| 41 | Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed |
| 42 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified. |
| 43 | M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified. |
| 44 | M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge. |
| 45 | S&F GI tubing 80 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position including taking down existing one complete all as specified. |
| 46 | All as per item NO 45 here in above but of size 50mm bore complete all as specified. |
| 47 | All as per item no 45 here in above but of size 40mm bore complete all as specified. |
| 48 | Make bore to road/cement path/hard standing by trenchless technology for providing GI pipe 40/50/80 mmboth end socketed for passing armoured cable incl making good the disturbed surface complete all as specified. |
| 49 | S&F in repalcement Bus Bar Chamber of size 30 x 30 x 15 cm suitable of 3 phase 433 Volts outdoor type and nuteralmade out of 3.15 mm thick M S Sheet with 100 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and fixing the busbar on the wallwith necessary fixing arrangement complete alongwith all necesary cableconnection with thimbles nut bolts etcs,lugs and cable gland including 2 coat of grey colour paint over a coat of red oxide primerall as directed. |
| 50 | All as per item no 49 here in above but of size 60x60x45cm with 400Amps busbar complete. |
| 51 | M&L for Dismantling insulators any type, any size from LT poles complete all as specified and directed by Engineer in Charge. |
| 52 | M&L for Dismantling cross-arms of M.S. channel or angle sections etc from LT poles and setting aside for re-use with in 50m complete all as specified and directed by Engineer in Charge. |
| 53 | M&L pin type porcelain vitreous white/brown/green insulator including one galvanized mild steel spindle and two galvanized iron washer and nut complete suitable for 1100 V grade 100mm height 65mm dia. |
| 54 | M&L forshackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 75 mm height and 90 mm dia including galvanized mild steel straps of section 31 x 3 mm size 12 mm dia bolt nut and washers complete all as specified and directed . |
| 55 | M&L for Cross arms bracing supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shapes or sizesinclusive of one primer coat complete all as specified and directed . |
| 56 | M&L for Dismantling of ACSR conductors after unbinding from insulators |
| 57 | Supply and fix in replacement of ACSR conductor weasel(6/1/2.59 mm)to bedrawn straighthorizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed, |
| 58 | Supply and fix in replacmement LT spacer 02 way FIX type made out of PVC materialand suitable to work on 1100 volts fixed between 02 conductors in any position along the LT line for any size of conductoralong the feedercomplete all as specified and directed. |
| 59 | Supply and fix in replacement LT spacer 05 way spiral type made out of PVC materialand suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductoralong the feedercomplete all as specified and directed. |
| 60 | S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185/240/300 Sq mm. |
| 61 | S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 70/150 Sq mm. |
| 62 | S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 4 core XLPE armoured aluminium conductor cable of size 35/50 Sq mm |
| 63 | S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 4 core XLPE armoured aluminium conductor cable of size 16/25 Sq mm |
| 64 | S&Fjoint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185/240/300 Sq mm. |
| 65 | S&F joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 70/150 Sq mm. |
| 66 | S&Fjoint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 4 core XLPE armoured aluminium conductor cable of size 25/35/50 Sq mm |
| 67 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 63 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 68 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 69 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 100 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 70 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 160 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 71 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 72 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 200 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 73 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 74 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 250 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 75 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 76 | S&F inreplacement ofMCCB with adjustable thermal and magentic setting typeRelease Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 77 | S&F inreplacement of ACB Microprossessor relese based type 50Hz, 4 Pole 630Amp 50 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 78 | Supply & fix LT feeder pillar panel weather proof outdoor type double door fabricated cout of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035( Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed ,dust & vermin proof,confirming to degree of protection IP-55,gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cyllendrical panel locked .The panel shall be provided with alluminium bus bars,electrolytic grade of adequate rating or as specified below.The bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable,non hygroscopic,SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated coper conductors cables of suitable size properly tagged and secured..The panel shall be provided with digital Voltmeter/Ammeter with cast resign CTs & RYB LED indicating lamps at incoming.Sthe panel shall be provided with heavy duty steel cable glands of adequate size for incoming & ali outgoing cables..the panel shall be provided with manufacturer name plate,skull & bone danger notice board etc. the panel shall be provided with 04 numbers 50mmx50 mmx6mm thick angle iron supports . duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth at per site requirement.All MCCBs shall be provided with spreader links with phase seperator on both sided and suitable extended rotary handle for incoming MCCB complete all as specified and as directed.. the panel shall be provided with and including the following accessories : (a) Aluminium bus bar -400 Amps rating suitable for 3 phase 4 wire system INCOMING:-(i)MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection-01 Nos(ii) Digital Ammeter 0-200 Amp-01 Nos(iii) Digital Voltmeter 0-500 Volt-01 Nos (iv)LED Indicating lamp R,Y, B-01 NosOUTGOING:-(i)MCCB 4P -160 Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection -02Nos (ii) MCCB 4P -250Amps 16 KA breaking capacity with fixed thermal & fixed magnetic-02 Nos |
| 79 | M&L in replacement earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and includinggalvanized earth lead strip 32X6 mm size upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and panel all as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,upto7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. |
| 80 | Taking down/out old unserviceable building Street light of any type / wattage and Supply and fixing LED light fittings 90 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, operating temp -20 degree to 50 degree,color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light controland comply to IEC60598/IS10322 necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm for connection complete all as specified and directed . |
| 81 | Restretching properly and tightening ACSR conductor including rebinding aftes straining the singleconductor on LT pole of any size replacing of jumpers if necessary all as directed by Engr-in-Charge. |
| 82 | Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete. (Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tendered for single operation only) |
| 83 | M&L for triming of tree branches (touching HT/LT OH line)uptto 100 cm girth at any height carefully taking shutdown including suitable disposal of cut of tree branches as in repair complete.Note:- tools & plants including safety measures equipments like belt,ladder & rops etc shall be arranged by the contractor at own cost. |
| 84 | M&L for preparation of old steel surfaces and applying alternatively in AF Pattern one coat of synthetic enamel black paint to steel tabular, pole upto 1 mtrheight from ground level and remaining with two coatsaluminium paint to LT pole and Cross arms including numbering of pole with black paintcomplete as specified. |
| 85 | Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts indoor type made out 2.0 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 50 x 5 0 x 6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland. and thecopper bus bar should be 1.5 time from themain incoming ( Main Panel)NOTE:-All MCCB\"s used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (A) ACB 4 pole 630 amps 50 KA- 01 No (incoming)(b) MCCB 4 pole 400 amps 50 KA- 01 No (To wall mounted panel for main campus) (c)MCCB 4 pole 200mps 36 KA- 02No (d) MCCB 4 pole 125 amps 36 KA- 02No(e) CHANGEOVER SWITCH OF CAPACITY 200 AMP 4 pole 440 volt onload type.(f) Ampere meter (digital type) 0-500 amps with selector switch - 01 No(g) Volt meter (digital type) 0-500 volts with selector switch - 01 No(h) Indicator lamp RYB (3 Nos) - 01 Set |
| 86 | Supply, Install , testing and commissioning of Wall Mounted LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted onangle iron 50x50x6 mm frame of the panel board , fitted on wall by proper cementong work, thimbling and cable entry boxes with cable gland. and thecopper bus bar should be 1.5 time from themain incomingNOTE:-All MCCB\"s used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels.(a) MCCB 4 pole 200 amps 25 KA- 01 No (incoming) (b)MCCB 4 POLE 63 amps 25 KA- 03No (outgoing toTPN DB for ligght/fan/socket point)(c) Ampere meter (digital type) 0-100 amps with selector switch - 01 No (d) Volt meter (digital type) 0-500 volts with selector switch - 01 No (e) Indicator lamp RYB (3 Nos) - 01 Set |
| 87 | Supply, Install , testing and commissioning of Wall Mounted LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted onangle iron 50x50x6 mm frame of the panel board , fitted on wall by proper cementong work, thimbling and cable entry boxes with cable gland. and thecopper bus bar should be 1.5 time from themain incoming NOTE:-All MCCB\"s used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a)MCCB 4 pole 320 amps 25 KA- 01 No (incoming)(b) MCCB 4 POLE 63 amps 25 KA- 05No (outgoing to AC 8.5 TON (c) Ampere meter (digital type) 0-100 amps with selector switch - 01 No(d) Volt meter (digital type) 0-500 volts with selector switch - 01 No(e)Indicator lamp RYB (3 Nos) - 01 Set |
| 88 | S&F MCCB DB VTPN 4 WAYdouble door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP43 protection complete all as specefied and directed. (Note: MCCB should be B or C curve as directed by engineer in charge) |
| 89 | S&F MCCB , TPN, 240 Volt , 125amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed. (Note: MCCB should be B or C curve as directed by engineer in charge) |
| 90 | S/Fix in replacement of old MCB DB TPN 4 Way with 200Amp standerd bus bar factory made IP 43 protection class metal double doorwith Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCB TPN upto 125A complete all as specified and directed.(MCB TPN will be measured and paid separately under respective items of sch A) |
| 91 | S&F MCB TPN240 volts 63 to 100 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: TPN should be B or C curve as directed by engineer in charge) |
| 92 | S&F MCB SP240 volts 40 to 63 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: TPN should be B or C curve as directed by engineer in charge) |
| 93 | S&F in repalcement Bus Bar Chamber of size 30 x 30 x 15 cm suitable of 3 phase 433 Volts outdoor type and nuteralmade out of 3.15 mm thick M S Sheet with 200 Amps rated COPPER busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and fixing the busbar on the wallwith necessary fixing arrangement complete alongwith all necesary cableconnection with thimbles nut bolts etcs,lugs and cable gland including 2 coat of grey colour paint over a coat of red oxide primerall as directed. |