| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth, for foundation, etc in any type soil and getting out.the pipe safely no Mechanical exacavator , mechanical damaged by manual should be utilised otherwise shedule of creditin form of pipes not feasible and shall be deducted as schedule of creditfrom contractor due to lack of workmanship. |
| 2 | Returning, fillingin, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation all as specified and directed. |
| 3 | Removing excavated material (Soil) not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | Taking up, 160 mm bore, UPVC/CPVC pipe of10 Kgwater mains (including all fittings)complete all as specified and directed. |
| 5 | Taking up,90 mm bore, UPVC/CPVC pipewater mains (including all fittings)complete all as specified and directed. |
| 6 | Taking up, 20-50 mm bore, UPVC/CPVC pipewater mains (including all fittings)complete all as specified and directed. |
| 7 | Taking up, 15 mm bore, UPVC/CPVC pipewater mains (including all fittings)complete all as specified and directed. |
| 8 | M&L for 160 mmUPVC/PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 9 | M&L for 90 mmUPVC/PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 10 | M&L for 50 mmUPVC/PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 11 | M&L for 40 mmUPVC/PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 12 | M&L for 25mmUPVC/PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 13 | M&L for 20 mmUPVC/PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 14 | M&L for 15 mmUPVC /PPR pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 15 | M&L for bib tap15 mm PTMT suitable forUPVC/PVCpipes, for Tertiary treated water complete all as specified and directed. |
| 16 | M&L for Sprinkler15 mm PVC/PTMT suitable forUPVC/PVCpipes, for Tertiary treated water complete all as specified and directed. |
| 17 | M&L for 160 mm ball valve / Butter Fly valve UPVC pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 18 | PVC /CPVC/UPVCColumn pipe 100 mm super Heavy3 mtr long for Sewage Pumps of make ashirvad or equivalent complete all as specified and directed. |
| 19 | PVC CPVC/UPCVC Column pipe 50 mm Neor Heavy3 mtr long for Sewage Pumps of make ashirvad or equivalent complete all as specified and directed. |
| 20 | M&L for 90 mm ball valve / Butter Fly valve UPVC pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 21 | M&L for 50 mm ball valve / Butter Fly valve UPVC pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 22 | M&L for 25 mm ball valve / Butter Fly valve UPVC pipes with all fittings and joiunting material ofany length laid in trenchesfor Tertiary treated water complete all as specified and directed. |
| 23 | SS/MS Column pipe End piecewith all accesoriescomplete for both endsuction and discharge complete in all respect for 100 mm Column Pipe complete all as specified and directed. |
| 24 | SS/MS Column pipe End piecewith all accesoriescomplete for both endsuction and dischargecomplete in all respect for 90 mm Column Pipe complete all as specified and directed. |
| 25 | SS/MS Column pipe End piecewith all accesoriescomplete for both endsuction and dischargecomplete in all respect for 50 mm Column Pipe complete all as specified and directed. |
| 26 | Supply and fixingautomatic star delta starter for sewage pump complete for 5-15 HPCurrent Setting Range10-25 Ampcomplete all as specified and directed. |
| 27 | Material and labour for Repair ofMCC panel with Soft starter setfor 3x 20 HP, 5x 7.5 HP, 3x 5 HP, 4x10 HP Including17 No MPCB 5-20 HAmp, 17 No Contactor 20-50 Amp AC-3 Duty,Satrt and Stop Push Button , MultifunctionMetercomplete including wiringetc all as directed by Engr-in-Charge |
| 28 | Supply and fixingMagnetic contactor 3 pole power contactors of AC-3 duty rating at 415V, 50Hz capacity 18A to 40A, heaving feature AC coil upto frame-4 and AC/DC universal coil with SMART ECM (Electronic control module)in-built for frame-5 to frame-8 conforms toIS/IEC 60947-4-1, finger proof IP20 terminals, Low VA burden wide operating band coils with class H insulation complete all as specified and directed. |
| 29 | Supply and fixingMagnetic contactor 3 pole power contactors of AC-3 duty rating at 415V, 50Hz capacity 32A to 55A, heaving feature AC coil upto frame-4 and AC/DC universal coil with SMART ECM (Electronic control module) in-built for frame-5 to frame-8 conforms toIS/IEC 60947-4-1, finger proof IP20 terminals, Low VA burden wide operating band coils with class H insulation complete all as specified and directed. |
| 30 | Supply and fixingMagnetic contactor 3 pole power contactors of AC-3 duty rating at 415V, 50Hzcapacity 40A to 60A, heaving feature AC coil upto frame-4 and AC/DC universal coil with SMART ECM (Electronic control module) in-built for frame-5 to frame-8 conforms toIS/IEC 60947-4-1, finger proof IP20 terminals, Low VA burden wide operating band coils with class H insulation complete all as specified and directed. |
| 31 | Supply and fixingMagnetic contactor 3 pole power contactors of AC-3 duty rating at 415V, 50Hzcapacity 50A to 70A, heaving feature AC coil upto frame-4 and AC/DC universal coil with SMART ECM (Electronic control module) in-built for frame-5 to frame-8 conforms toIS/IEC 60947-4-1, finger proof IP20 terminals, Low VA burden wide operating band coils with class H insulation complete all as specified and directed. |
| 32 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 4A-6A, having feature range-0.12A - 800A available in 8 frames, trip class-10A, conforms to IS/IEC 60947-4-1, protection against overload & phase loss protection, auto manual reset facility, contactor mounting/ individual mounting with adaptor, transparent protection cover for dust application complete all as specified and directed. |
| 33 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 8A-12A, having feature range-0.12A - 800A available in 8 frames, trip class-10A, conforms to IS/IEC 60947-4-1, protection against overload & phase loss protection, auto manual reset facility, contactor mounting/ individual mounting with adaptor, transparent protection cover for dust application complete all as specified and directed. |
| 34 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 12A-18A, having feature range-0.12A - 800A available in 8 frames, trip class-10A, conforms to IS/IEC 60947-4-1, protection against overload & phase loss protection, auto manual reset facility, contactor mounting/ individual mounting with adaptor, transparent protection cover for dust application complete all as specified and directed. |
| 35 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 17A-25A, having feature range-0.12A - 800A available in 8 frames, trip class-10A, conforms to IS/IEC 60947-4-1, protection against overload & phase loss protection, auto manual reset facility, contactor mounting/ individual mounting with adaptor, transparent protection cover for dust application complete all as specified and directed. |
| 36 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity8A-12.5A, having feature 5 frame sizes current rating, trip class 10A and built in SPP, direct mounting to all contactors, IP20 guarded terminals prevent accidental contact with live parts complete all as specified and directed. |
| 37 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 10A-15A, having feature 5 frame sizes current rating, trip class 10A and built in SPP, direct mounting to all contactors, IP20 guarded terminals prevent accidental contact with live parts complete all as specified and directed. |
| 38 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 11A-17A, having feature 5 frame sizes current rating, trip class 10A and built in SPP, direct mounting to all contactors, IP20 guarded terminals prevent accidental contact with live parts complete all as specified and directed. |
| 39 | Supply and fixingThermal over load relay (Auto/Manual reset) of relay range capacity 22A-32A, having feature 5 frame sizes current rating, trip class 10A and built in SPP, direct mounting to all contactors, IP20 guarded terminals prevent accidental contact with live parts complete all as specified and directed. |
| 40 | Supply and fixingMPCB (Motor protection circuit breaker) of breaking capacity 50kA 415, V 50Hz, current rating 6.3A - 10 A specially coordinated for IE2,IE3 & IE4 motors, heaving feature rotary version -2 frame sizes, 45mm and 55 mm width, thermal magnetic version - range from 0.1-63A, trip class 10, magnetic oly version - Range from 0.16A-63A, rated operational voltage-makes it suitable for IE2, IE3 and IE4 motors, compliance to IEC-60947-2 and IEC 60947-4-1, finger proof IP20 terminals, lockable in OFF position, suitable for DIN channel and base mounting both, CE marking complete all as specified and directed. |
| 41 | Supply and fixingMPCB (Motor protection circuit breaker) of breaking capacity 50kA 415, V 50Hz, current rating 20A - 25A specially coordinated for IE2,IE3 & IE4 motors, heaving feature rotary version -2 frame sizes, 45mm and 55 mm width, thermal magnetic version - range from 0.1-63A, trip class 10, magnetic oly version - Range from 0.16A-63A, rated operational voltage-makes it suitable for IE2, IE3 and IE4 motors, compliance to IEC-60947-2 and IEC 60947-4-1, finger proof IP20 terminals, lockable in OFF position, suitable for DIN channel and base mounting both, CE marking complete all as specified and directed. |
| 42 | S&F in repair smart push button - Green |
| 43 | S&F in repair smart push button - red |
| 44 | S&F in repair Motor ON indicating light - Green |
| 45 | S&F in repair Motor ON indicating light - Red |
| 46 | S&F in repair SPP |
| 47 | S&F in repair combined voltmeter & ammeter |
| 48 | S&F in repair terminal block 6 way |
| 49 | S&F in repair terminal block 3 way |
| 50 | S&F in repair volt sel Switch C/G |
| 51 | S&F in repair timer |
| 52 | S&F in repair front block 1No 1NC |
| 53 | S&F in repair Mini rocker switch - SPP by pass |
| 54 | Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified. |
| 55 | Sub class \"B\" old size well burnt brick laid flate in trenches as protection to LT cable complete all as specified and as directed. |
| 56 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 70 Sqmm complete all as specified and directed. |
| 57 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 50 Sqmm complete all as specified and directed. |
| 58 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 35 Sqmm complete all as specified and directed. |
| 59 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 25 Sqmm complete all as specified and directed. |
| 60 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specified and directed. |
| 61 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specified and directed. |
| 62 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by ENgr-in-charge |
| 63 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipeandLT cablesalong the pipeof size 50 mm dia GI pipe complete all as specified and directed |
| 64 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipeandLT cablesalong the pipeof size 100 mm dia GI pipe complete all as specified and directed |
| 65 | S&F GI tubing light grade galvanised with all fittings & fixed complete wall/pole for 40mm bore complete all as specified and directed. |
| 66 | S&F GI tubing light grade galvanised with all fittings & fixed complete wall/pole for 50 mm bore complete all as specified and directed. |
| 67 | S&F GI tubing light grade galvanised with all fittings & fixed complete wall/pole for100 mm bore complete all as specified and directed. |
| 68 | M/L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in foundation/surface repair etc complete all as specified and directed. |
| 69 | S & F cable Tray on 100mm size50 mm depth16 gaugewith MS angle iron 50mm x 50mm x 6mm C- Framepost supportgrouted in ground min 30cm and above the ground 35 cm including PCC 1:3:6 type C-1 all as directedby engr-in-charge. |
| 70 | S & F cable Tray on 150 mm size50 mm depth16 gaugewith MS angle iron 50mm x 50mm x 6mm C- Framepost supportgrouted in ground min 30cm and above the ground 35 cm including PCC 1:3:6 type C-1 all as directedby engr-in-charge. |
| 71 | S & F cable Tray on 300 mm size 50 mm depth16 gaugewith MS angle iron 50mm x 50mm x 6mm C- Framepost supportgrouted in ground min 30cm and above the ground 35 cm including PCC 1:3:6 type C-1 all as directedby engr-in-charge. |
| 72 | S & F cable Tray on 50 mm size50 mm depth16 gaugewith MS angle iron 50mm x 50mm x 6mm C- Framepost supportgrouted in ground min 30cm and above the ground 35 cm including PCC 1:3:6 type C-1 all as directedby engr-in-charge. |
| 73 | Supply and fixing inreplacaement/ Modification of ADR Device for 8 and 13 PassengerLift with matching to existingControl and Logic Programme complete all as specified and directged. |
| 74 | Material and labour for Replacement of Set ofTwo Filter for DG Set FuelFilter Pre filter and Micro Filter of Make Mico/Bosch/Kirloskar /Cummins /MahindraOf Capacity 15 - 160 KVA |