| 1 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 2 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 3 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 4 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 5 | 10 x 60 mm |
| 6 | 10 x 120 mm |
| 7 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 8 | Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 9 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width etc. as per direction of Engineer-in-charge. |
| 12 | LMR ITEM |
| 13 | Taking out existing eternia window of different shape and size for provision of Gypsum wall partition between eternia window and power equipment etc. by opening of all members of eternia window, having double glazing toughened glass hermetically sealed and argon gas filled, with proper safety and security of all members etc. all complete as per direction of Engineer-in-Charge. |
| 14 | Refixing of eternia window in same position, after installation of gypsum wall partition between eternia window and power equipment etc., i/c provision of cutting and fixing of existing member and additional member(if required)etc. all complete as per direction of Engineer-in-Charge (all items of Gypsum partition wall shall be paid in relevant item) |
| 15 | Providing & fixing at all floor& at all heights, 12.5 mm thick.fire reistant and moisture resistant Gypsum plaster board conforming to IS: 2095: part 1 (Board with BIS certification marks) of make Gyproc, Knauf, Everest, Gyocore or equivalent on one side ofsteel tube frame with the help ofGyproc metal to metal secrew or Dry wall secrews of required size at every 600mm c/c or as per JIS G3507-1 standard. The square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc® Pro-Fill Jointing compound, (Conforms to ASTM C475) Gyproc® Joint Paper tape or fibre tape etc. as per direction of Engineer-in-charge.The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti/Pyroplex fire and acoustic sealant.The rate includes all the material & labour &scaffolding requiredfor all above process (Except Steel tube frame and painting of board) . |
| 16 | Providing and fixing 24mm thick [6mm + 12mm + 6mm] double glazing with 6mm thick toughned glass of make Saint Gobainhermetically sealed and Argon gas filledhaving seal type internal and external overlapping central gasket and rabbet (EPDM) Co-extrudedfor weather resistance all complete and as per the direction of Engineer-in-Charge. |
| 17 | Providing and fixing carbon steel galvanized dash fastener of 75mmx8mm size for fixing of windows etc. all complete as per direction of Engineer-in-charge. |
| 18 | Repair of window sill and wall of different size, damaged during taking out and refixing of eternia window , by putty, paint, etc. all complete as per direction of Engineer-in-Charge. |
| 19 | Providing & Fixing of Door frame of size (125X 55 ) mm with inbuilt rebate profile made out of 1.60 mm thick galvanized steel sheet (Zinc coating not less than 120 gm/sqm) . Frames shall be Butt jointed and assembled with bolting system for strength. Door leaf single/double should be 60 mm thick fully flush double skin, manufactured from 1.2mm thick galvanised steel sheet and shall be provided with reinforcement pads & necessary provision for receiving appropriate Hardware. The Shutter shall be filled with infill material honey comb kraft paper density 180 GSM or proprietary infill material insulation as per prototype test report. Vision panels will be of 120 minutes fire rating. The glass of vision panel shall be clear , toughened, non wired fire resistant of 6 mm thickness of SAINTGOBAIN//EQ approved brand with 120 minutes of fire resistance. The glass shall be able to withstand fire attack from both side. Shutter shall be fixed to frame with SS 304 ball bearing hinges of approved make as per direction of E-I-C. The door frame and shutter shall be finished with powder coating RAL 7035. |
| 20 | Providing and fixing 2 hr fire rated door closer make Becke FS Make BLC 604 STND ARM or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete. |
| 21 | Providing and fixing concealed flush bolt in bottom/Top for metal door 300mm. |
| 22 | Providing and fixing concealed flush bolt in bottom/Top for metal door 600mm |
| 23 | Providing and fixing floor socket. |
| 24 | Providing and fixing 6mm thick vision panel 150 mmX800mm or 150 mm X 600 mm make Saint Gobin or equivalent having 2 hr firerating or as per the tested proto type FRD with complete assembly. |
| 25 | Providing and fixing mortise sash lock Becker fs makeSL 7260K, Level handle set & 70 mm cylinder with bothe side key. |