| 1 | Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection harges of TPI Agency approved by MJP including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, ortation to departmental store,unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets. |
| 2 | 100 mm |
| 3 | Lowering laying and jointing with SBR ruber gaskets C.I. S/S pipes of various classes with CI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer-in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour etc. complete. |
| 4 | 100 mm |
| 5 | Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R, complete with cast iron follower gland and M. S. nut bolts coated or otherwise protected from rusting and suitable for D.I.pipes including cost of labour ,materials, and transportation to stores / site, loading and unloading excluding GST levied by GOI & GOM in all respect, omplete as per IS-9523.For all types of specials, bends tees etc. |
| 6 | 100 mm dia. |
| 7 | Hydraulic testing of C.I./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position using water supplied by the contractor |
| 8 | 100 mm |
| 9 | D.I. Socket and flanged fittings :-Providing and supplying D.I. fitting with ISI mark socket pushon joints or flanged joints confirming to table 12 to 31 of IS 9523/2000 upto latest amendments including cost of SBR/ EDPM tyton rings. Fittings should be with internally ordinary portland Ement mortor lined and externally metallic zinc coating/zinc rich paint with finishing layer of black bitumen coating including transportation & excluding all statutary duties and taxes such as GST levied by Gol nd GoM in all respect etc. complete |
| 10 | Double socket bend 90 degree - 100mm dia |
| 11 | Double socket bend 45 degree - 100mm dia |
| 12 | Double Socket Tee with Flange branch-PN-10-100mm dia |
| 13 | Flange Spigot-PN-10-100mm dia |
| 14 | Double Flange Bend 90 Deg -PN-‘10 -100mm dia |
| 15 | Double Flange Bend 45Deg -PN-‘10 -100mm dia |
| 16 | All Flange Tee -PN-10 - 100 x 100mm dia |
| 17 | Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. |
| 18 | 300mm |
| 19 | Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS-783-1985. |
| 20 | 300mm |
| 21 | Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes intheir position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameterof branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores) |
| 22 | 100mm |
| 23 | Valve Chamber with Precast RCC Covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. |
| 24 | As above of 1.2 x 1.2 M internal size and depth upto 1.2 M with precast R.C.C slab cover. |
| 25 | Providing and fixing C.I. road box including loading,unloading and carting to site of work including allnecessary excavation in all types of strata and fixing inmurum packing, etc. complete. |
| 26 | 225 mm x 300 mm (40 kg) |
| 27 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) |
| 28 | Lift 0 to 1.5 M |
| 29 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation andexcluding backfilling, etc. complete. (Bd-A-4/259) |
| 30 | Lift 0 to 1.5 M |
| 31 | Excavation for foundation / pipe trenches in hard rock and concrete road bychiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means.(Bd-A-6/259) |
| 32 | for concerating road pipe line |
| 33 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge(including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) |
| 34 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete |
| 35 | Providing dry trap/granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 36 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite/ gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.(Cement 5.90 bags / cum) |
| 37 | In PCC M-150 |
| 38 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc.complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 39 | In RCC M-200 |
| 40 | Centrifugal Monoblock Pumpset (Two Stage) |
| 41 | Removable mechanism type Bulk water meter as per ISO 4064Providing, installing and giving satisfactory field testing of bulk water meter, horizontal inferential multijet type with magnetic drive and dry dial suitable for ambient 50º C Temperature duly sealed against tampering complete with flanges at both ends and conforming to class B as per ISO 4064 along with manufacturer\"s test certificate and guarantee certificate, including cost of all materials and labour etc with OIML. MID certification for Abroad meter and FCRI for India including 36 months guaranteeetc complete. |
| 42 | 100mm dia |
| 43 | C.I. Strainer \"T\" (Basket) Type with flanged endsProviding, and fixing C.I.Strainer for water meters including cost of all material and labour.of \"T\" (Basket) Type with flanged ends and with stainless steel or brass mesh with openings of 2.5.mm to 3 mm and suitable for operating pressure of 16 Kg./cm2 and test pressure of 24Kg./cm2 |
| 44 | 100mm dia |
| 45 | 3 core PVC insulated, PVC sheathed copper conductorflat submersible cableSupplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed |
| 46 | CB 1-6 3 core 16 sq mm |
| 47 | Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part (1984) |
| 48 | With by pass arrangement - PN -1.6 |
| 49 | 100mm |
| 50 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmentalstore, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Sluice valve - PN - 1.6 (With by pass arrangement) |
| 51 | 100mm |
| 52 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves). |
| 53 | 100mm |
| 54 | Providing and supplying Air Valves as per IS-14845 and MJP’s standard specifications double orifice type combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete.Air Valve Double Ball Flanged Type - PN - 1.6 |
| 55 | 100 mm |
| 56 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves). Kinetic Air Valve (PN-1 and PN - 1.6) |
| 57 | 100mm |
| 58 | XIII. MECHANICAL JOINTS / FITTING Supply and fixingof C. I. Mechanical Compression Collar Coupling suitable for C.I. Spun Pipes ( as per - IS - 1536 /2001) and complete with sealing rubber gasket of SBR,.C.I. follower Glands and M.S. nut Bolts.The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS:1538 /1993 |
| 59 | 100mm dia |
| 60 | Supply and fixing of CI Mechaincal joint Double Socket Reducers as described in Table -21 of IS - 13382/1992 complete with sealing ubber gasket of SBR( dimensionally described in IS-12820/ 1989) with cast iron follower gland and mild steel nut bolts coated or otherwise protected from rusting and suitable for C.I. pipes |
| 61 | 100x80 mm dia |