| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, asdirected by the Engineer-in- Charge.All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 4 | Providingandlayinginpositioncementconcreteofspecified grade excluding the cost of centering and shuttering -1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Providingandlayinginpositionspecifiedgradeofreinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns,pillars,piers,abutments,postsandstrutsetc. above plinth level upto floor five level excluding cost ofcentering,shuttering, finishing and reinforcement :1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 8 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | Halfbrickmasonry withIstclasscommonburntclayF.P.S.(non modular) bricks in foundation and plinth in:Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 10 | ReinforcementforR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete up to plinth level.Thermo-Mechanically Treated bars |
| 11 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in positionand applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 13 | (a)Foundations, footings, bases of columns, etc. for mass concrete. |
| 14 | (b)Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | (c)Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required withPrecoated galvanised iron Precoated galvanised iron profile sheets0.40 mm thick |
| 17 | Providing and fixing tiled False Ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet,spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spacedbetween main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sectionsshall be pre-painted with polyester paint, all complete at allheights as per specifications, drawings and as directed by Engineer-in-Charge. (The rate is excluding the cost of tiles which will be paid |
| 18 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate. |
| 19 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :1:3(1 cement: 3 coarse sand) |
| 20 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 21 | Finishing walls with Acrylic Smooth paint of required shade: —New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. overand including base coat of water proofing cement paint applied @2.20 kg/ 10 sqm). |
| 22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc.,complete.Size of Tile 600 x 600 mm |
| 23 | Providing and fixing glazing in aluminium door, window, ventilator shuttersandpartitionsetc.withEPDMrubber/neoprenegasket etc. complete as per the architectural drawings and the directions ofengineer-in-charge. (Costofaluminiumsnapbeadingshallbe paid in basic item):With float glass panes of 4.0 mm thickness |
| 24 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 25 | Carriage of material by Mechanical transportfrom item no.3 |
| 26 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 27 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 28 | WIRING |
| 29 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5mm2 FR PVC insulatedcopper cond. S/C cable in surface/ recessed PVC conduitwith modular type switch, modular platesuitable size GI- box and earthing the point with 1.5mm2 FR PVC insulated copper. cond. S/C cableetc.as reqd. |
| 30 | 1.Group A |
| 31 | 2.Group B |
| 32 | 3.Group C |
| 33 | Wiring for light point/power plug with 2x4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 no. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc. as required |
| 34 | Wiring for circuit / sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable inin surface/ recessed PVC conduit etc. as reqd. |
| 35 | 1.2x2.5mm2 +1x2.5mm2 earth wire. |
| 36 | 2. 2 x 4mm2 + 1 x 4mm2 earth wire. |
| 37 | 3.2 x 6mm2 + 1 x 6mm2 earth wire. |
| 38 | 4.2 x 10mm2 + 1 x 10mm2 earth wire. |
| 39 | S/F (following modular type switch/socket) on the existing switch switch box/cover i/c connection etc. as reqd. |
| 40 | i) 15/16 amps switch. |
| 41 | ii) 15/16 amps socket outlet. |
| 42 | iii) 5/6 amps switch. |
| 43 | iv) 5/6 amps socket outlet. |
| 44 | v) Modular Blanking Plate |
| 45 | S/F (following size/ modules) G.I. Box along with modular base and cover plate for modular switch in recessas reqd. |
| 46 | 1. 1 or 2 module (75mmX 75mm) |
| 47 | 2. 4 module (125mmX 75mm) |
| 48 | 3.6 module (200mm X 75mm) |
| 49 | 4. 8 module (125mmX 125mm) |
| 50 | 5. 12 module (200mmX 150mm) |
| 51 | Fixtures |
| 52 | S/F CFL bulk head luminaries deep down annodised Al.body,heat resistant prismatic glass cover . |
| 53 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc. |
| 54 | S/F 48\"\" sweep (1200mm) A.C. ceiling fan complete with down rod, cannopy, 3(three) blades but without regulator etc. as reqd. (Make Bajaj/Usha or similar). |
| 55 | S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd. |
| 56 | S/F Recess mounting LED down lightetrs BGSL 0101WH ,220223 cast aliminium housing ,fixed with collimated lens , 1 x 1 w white LED mounted on MCPCB , extreded AL. Heat sin spring loaded mounting clips complete with connection etc as reqd. |
| 57 | Switchgear |
| 58 | S/F (2+6 )say single door/double door and neutral, sheet steel, MCB distributon board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinge front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. |
| 59 | S/F 5 amp. to 32 amp. Rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd. |
| 60 | S/F 63amp double pole 240V isolator in the existing MCBDB complete with connection, testing and commissions etc. as reqd. |
| 61 | 16 Sqmm ISI mared PVC insulated AL cable |
| 62 | Supply of PVC sleeve |
| 63 | Supply 25 mm dia ISI marked, PVC Conduit. |
| 64 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 65 | All kinds of soil. |
| 66 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 67 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 68 | All work upto plinth level: |
| 69 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 70 | Extra for providing and mixing water proofing material in cement concrete work @1 kg per 50 kg of cement. |
| 71 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 72 | 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 73 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 74 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level and above plinth level |
| 75 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 76 | Foundation,footings,bases of columns etc.and mass concrete |
| 77 | Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick. |
| 78 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 79 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 80 | 1:4 (1 cement: 4 fine sand) |
| 81 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & Ci.I. brackets, 40mm flush bend , overflow arrangements with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and flors wherever required |
| 82 | W.C. pan with ISI marked white solid plastic seat and lid |
| 83 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 84 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 85 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 86 | Kitchen sinkdrain board510x1040mm bowl depth 178mm |
| 87 | Providng and fixing 8mm dia C.P. / S.S Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C of quality and make as approved by Engineer-in-charge. |
| 88 | Providing and fixing CP brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge |
| 89 | Providing and fixing PVC waste pipe for sink or wash basin iincluding P.V.C waste fittings complete. |
| 90 | Semi rigid 40mm dia |
| 91 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 92 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 93 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 94 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 95 | Providing and fixing toilet paper holder: |
| 96 | C.P. brass |
| 97 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 98 | External work |
| 99 | 40 mm nominal outer dia Pipes |
| 100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 101 | Concealed work, including cutting chases and making good the wall etc. |
| 102 | 20 mm nominal outer dia Pipes |
| 103 | 32mm nominal outer dia pipes |
| 104 | Providing and fixing brass bib cock of approved quality : |
| 105 | 20 mm nominal bore |
| 106 | Providing and fixing brass bib cock of approved quality : |
| 107 | 20 mm nominal bore |
| 108 | Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms |
| 109 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 110 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 111 | 16 mm nominal bore, weighing not less than 32 gms |
| 112 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 113 | With common burnt clay F.P.S. (non modular) bricks |
| 114 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 115 | 75 mm diameter |
| 116 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 117 | Coupler |
| 118 | 75 mm |
| 119 | Bend 87.5° |
| 120 | 75 mm bend |
| 121 | 12.38.6.Shoe (Plain) |
| 122 | 75 mm Shoe |
| 123 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |