| 1 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 2 | M&L for hardcore of guage exc 63mm but not exc. 100 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 3 | M&L for 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) as in sub base etc complete all as specified and directed. |
| 4 | M&L for chequered tiles 400x400x35mm thick, coloured ,rubber pressed and glossy finished, set jointed in neat cement slurry in floors with grey cement and pigment complete over and including20 mm thick screed bed in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Material and labour for cement concrete type B-1, (1:2:4) (using20 mm graded stone aggregate) as in benching/coping and the like including weathering slightly round or chamfered angles and threadingcomplete all as specified and directed. |
| 6 | S&Fsolar illuminated roadkerbin standard size 0.5 mtrall as per manufacturer instructions complete all as specified and directed. |
| 7 | M&L for Reinforced concrete pipes 150 mm dia, class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 8 | M&L for preparation of newly concrete surface over 10 cm in width or girth and apply two coat of synthetic enamel paints over a coat of primer complete all as specified and directed. |
| 9 | S&F in repair solar road delineator 6 LEDs of colour red/ yellow housed in plastic body, LEDs, solar-cells, battery and light sensor well protected inside, polycarbonate sheet; device protected with powder coated wire mesh, cage. System mounted over 47 mm dia steel tube powder coated of length 600 mm having sheet foot for firm grip to ground. Delineator to have additional reflective bands. System workable for 2-3 days (nights) after full charge for 8-10 hours complete all as specified and directed. Note: Delineators with extra height can also be made (without any extra cost to Govt) e.g. of height 750, 900 OR 1000mm. |
| 10 | M&L for 2.5 mm thick painting to road surfaces as in lines, dashes, arrows, letters, zebra crossing etc on roads, pavements and the like etc. with thermoplastic road marking paint incl applying type-II glass beads dispensed from the in built while the painting surfaces are hot by mechanical means including cleaning surfaces complete all as specified and as directed.Note: Application shall be carried out through mechanical appliances by the approved applicator of the manufacturer of paint. |
| 11 | M&L for granite (of any type) tiles 20mm thick machine cut,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade pf granite stone including grinding and polishing complete all as specified and directed. |
| 12 | M & L for machine cut cudappa stone slab 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 13 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 14 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor 75 mm bore complete all as specified and directed. |
| 15 | Excavation in trenches not exceeding 1.5m in depth and 1.5m in widthand getting out in any type of soil complete all as specifiedand directed. |
| 16 | M&L for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) in foundation, mass concrete and filiings complete all as specifiedand directed. |
| 17 | M&L for brick work with fly ash brick old size straight or curved on plan exc 6 m mean radius built in CM 1:4complete all as specified and as directed. |
| 18 | M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth without using extra cement complete all as specifed and directed. |
| 19 | M&L for preparation of newly plastered surfaces of wall and applyingtwocoats ofcement base paint over a cost of cement primer complete all as specifed and directed. |
| 20 | Returning, filling in, including spreading levelling watering and well ramming in layers n.exc 25cm in any type of soil complete all as specified and directed. |
| 21 | M&L for Providing precast RCC ( 1:2:4 ) type B1 (using 20 mm graded stone aggregate ) as inlandings,cover slabs shelves and set in CM 1:4 etc.including all necessary formwork complete all as specified and directed. |
| 22 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 23 | M&L for Earth Filling under floor for raising plinth height incl spreading in layer not exc 30 cm thick watering, ramming/ rolling and finishing to required size shape not exc 1.5m high from base complete all as specified and directed.Note:- quoted rate deemend to be including excavation, loading unloading, transportation and royality of soil, if any |
| 24 | S&F in repirs retro reflective boards of shape of reactangular 1.0mx1.40 m made out of 2 mm thick stainless steel sheet both side bounded / pasted with high prismatic (IV) sheet as manufactured with desired letters / logos / designed as directed. The board shall be supplied with and incl stain less steel frame made out of 25 mm dia pipe in frame around duly welded and embaded in PCC 1:2:4 type B2 of size 0.45 x 0.45 x 0.60 mtr incl necessary earth work with and including stain less steel sheet and SS post of 38 mm dia and full length of 2.20 mtr one side and 2.8 mtr on other side complete all as directed.Note:- The quoted rate includes PCCbed block necessary earth workin any type of soil incl disposal of excavated earth out side of defence land complete all as specified and directed. |