Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling concrete poles/ struts, any size and type and setting aside for reuse within 50 metre, complete all as specified and directed. |
| 2 | Dismantling of unserviceable cross arm such as MS channel /angle section etc and setting aside for re-use with in 50m, complete all as specified and directed. |
| 3 | Dismantling of ACSR or AAC conductors , complete all as specified and directed. |
| 4 | Dismantling insulators of any type and size , complete all as specified and directed. |
| 5 | Dismantling stay assembly complete (demolition of concrete, etc. and excavation measured separately), complete all as specified and directed. |
| 6 | Disconnecting & taking out defective LT underground cable/ service wire any size and any type from trenches, pole, pipe, floor, watt etc., complete all as specified and directed. |
| 7 | Disconnecting & taking out defective HT underground cable/ service wire any size and any type from trenches, pole, pipe, floor, watt etc., complete all as specified and directed. |
| 8 | Excavating in trenches in SOFT/LOOSE soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out, complete all as specified and directed. |
| 9 | Excavation in trenches in SOFT/LOOSE soil for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and depthexceeding 1.5 meter and not exceeding 3 metre and getting out , complete all as specified and directed. |
| 10 | Returning, filling in SOFT/LOOSE soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed . |
| 11 | Removing excavated material not exceeding 50m and depositing where directed at a levelnot exceeding 1.5 m above the starting point ,complete all as specified and directed. |
| 12 | Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmsdeep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed.Note- Punned quantity of sand shall be measured for purpose of payment. |
| 13 | Supply and lay bricks, common burnt clay, sub class \"B\", old size, designation 75 &laid in perpendicular direction to cable as cable protection complete all as specified and directed. |
| 14 | Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation ,complete all as specified and as directed. |
| 15 | Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surfaces finished smooth and even,complete all as specified and as directed. |
| 16 | Material and labour for PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement, complete allas specified and directed at site. |
| 17 | Material and labour forGalvanised iron tubing light grade ,80 mm bore of tube,fixed on walls / laid in trenches as protection pipe for under ground cable including all fittings, clamps etc including taking down of old unseviceable pipe any type and any sizecomplete all as speified and directed.( Note - Excavation to be paid separately in respective items) |
| 18 | Material and labour forGalvanised iron tubing light grade,100 mm bore of tube,fixed on walls / laid in trenches as protection pipe for under ground cable including all fittings, clamps etc including taking down of old unseviceable pipe any type and any size complete all as speified and directed.( Note - Excavation to be paid separately in respective items) |
| 19 | Material and labour forGalvanised iron tubing light grade,50 mm bore of tube,fixed on walls / laid in trenches as protection pipe for under ground cable including all fittings, clamps etc including taking down of old unseviceable pipe any type and any sizecomplete all as speified and directed.( Note - Excavation to be paid separately in respective items) |
| 20 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and as directed. |
| 21 | Material and labour for cutting of bituminious road/ hard standing/PCC path/wall up to a size not exceeding 20cm widthand not exceeding 60cm in depth for laying ofprotection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm graded crushed stone aggregate upto existing surface level or removingany type of tiles carefully and refixing properly as per existing surface, complete all as specified and as directed. |
| 22 | Material and labour for UG cable route indicator or cable joint mark for 1100 volts made out of mild steel 100mm dia 6mm thick plate welded to 25 x 25 x 3mm angle iron 50 cm long embeded in PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) block of size of 150mm x 200mm x 200mm including applying two coats of synthetic enamel paint over a coat of redoxide primer on steel surfaces ,complete all as specified and as directed. |
| 23 | Disconnecting & taking out existng street light any type/size from PCC/Steelpoleand re-fixing of the same on new steel tubular pole,complete all as specified and as directed. |
| 24 | Supply and laying3.5 core XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoued, electric power cable (heavy duty) 1100 volts grade with stranded aluminimum conductor with cross sectional area240 sqmm, laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed. ,complete all as specified and as directed.(Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately ) |
| 25 | All as per Ser item No 24 here in before but cross sectional area185 sqmm ,complete all as specified and as directed. |
| 26 | All as per Ser item No 24 here in before but cross sectional area150 sqmm ,complete all as specified and as directed. |
| 27 | All as per Ser item No 24 here in before but cross sectional area120 sqmm ,complete all as specified and as directed. |
| 28 | All as per Ser item No 24 here in before but cross sectional area95 sqmm ,complete all as specified and as directed. |
| 29 | All as per Ser item No 24 here in before but cross sectional area70 sqmm ,complete all as specified and as directed. |
| 30 | All as per Ser item No 24 here in before but cross sectional area50 sqmm ,complete all as specified and as directed. |
| 31 | All as per Ser item No 24 here in before but cross sectional area35 sqmm ,complete all as specified and as directed. |
| 32 | All as per Ser item No 24 here in before but cross sectional area25 sqmm ,complete all as specified and as directed. |
| 33 | Supply and laying4 core XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoued, electric power cable (heavy duty) 1100 volts grade with stranded aluminimum conductor with cross sectional area16 sqmm, laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed. ,complete all as specified and as directed.(Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately ) |
| 34 | All as per Ser item No 33 here in before but cross sectional area10 sqmm ,complete all as specified and as directed. |
| 35 | Supply and erection in truly verticle position , steel tubular swaged poles 9.0 metre long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, providing synthetic enamel aluminium paint over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 metre above the coping of pole starting with black strip,complete all as specified and as directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii)Any description of pole as directed by GE will be printed on each pole without any extra cost. |
| 36 | Material and labour for GI Bracket fabricatedout of light grade GI tubing 40 mm dia or as per dia of fitting , 1.5 metre long and along with 02 sets of suitable size of clamps and nuts and bolts to fix the bracket on Steel tubular pole 410 SP 31, including dismantling and taking down of existing street light bracket with clamp,complete all as specified and as directed. |
| 37 | M & L for drawing of PVC insulated and FR PVC Round Sheathed 1.5 sqmm, 3 core copper conductor ,industrial cable through steel tubular pole from bottom to Top hole and both side connection in Jn box MCB and Street light fitting ,complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of junction box insulated, of polycarbonate with glass fiber reinforced, size205mm X 255mm X 112mm,environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive,rated for degree of ingress protection IP 66/67 in accordance with IEC 60529, gasket material ofpolyurethane and the gasket shall be internally embedded, compliing with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670-22 & IEC 60670-2-5,including three phase busbar with 6 Amp MCB and mounting clamp complete all as specified and directed and complying the instructions as specified in notes here under.Note:- (i)The manufacturer of junction box shall submit a copy of IEC certificate. (ii) For better safety the polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11 DIN VDE 0304 Part 3, UL subject 94 for flammability V-2. (iii)It should be tested at glow wire test for 960 degree Celcius. (iv) The impact strength of polycarbonate enclosures i.e. the degree of protection against mechanical load shall be in accordance with EN 50296-98 for IK 08. Manufacturer should submit routine test certificate for CJB/PJB. |
| 39 | Supply, installing, testing & commissioning in replacement ofoutdoor type cubical panel board of suitable size ,outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm grouted with PCC 1:2:4 type B-1 ,frame factory fabricated with front and back openable double door system and cable alloy(Each door hinged with body at 2 places with body and hinges should be welded with body and door) with locking arrangementsand outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, including Al bus bar , 3 ph(RYB) of 1000 A and 1 Ph (neutral) of 500 A, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011Part-1 andpart -2 type test certificate with not less thanIP-65and breaking capacity 65 KA .(Location - Manoj Pandy Main Xmer Panel) (a) ACB630 Amps, Amps 4 pole 415 Volts AC , 50 KA. - 01 No (Incoming)(b) MCCB400 Amp, 415 volt, 4 pole, 36 KA ,(Outgoing)-02 Nos. (c) MCCB200 Amp, 415 volt, 4 pole, 36 KA ,(Outgoing)-02Nos. (d) MCCB100 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (e) Digital Multifunction meter with suitable size of CTs. - Set of 03(f)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates. |
| 40 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 600 A and 1 Ph (neutral) of 300 A and comprising of the following :-(a) MCCB400 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB250 Amp, 415 volt, 4 pole, 25 KA ,(Outgoing)-01 Nos. (c) MCCB200 Amp, 415 volt, 4 pole, 25 KA ,(Outgoing)-03 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 41 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 600 A and 1 Ph (neutral) of 300 A and comprising of the following :-(a) MCCB400 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB200 Amp, 415 volt, 4 pole, 25 KA ,(Outgoing)-03 Nos. (c) Digital Multifunction meter with suitable size of CTs. -set of 03(d)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 42 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 400 A and 1 Ph (neutral) of 200 A and comprising of the following :-(a) MCCB250 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB100 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-03 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 43 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 300 A and 1 Ph (neutral) of 150 A and comprising of the following :-(a) MCCB250 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB100 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-06 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 44 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 400 A and 1 Ph (neutral) of 200 A and comprising of the following :-(a) MCCB250 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB125 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (c) MCCB100 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 45 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 600 A and 1 Ph (neutral) of 300 A and comprising of the following :-(a) MCCB400 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB250 Amp, 415 volt, 4 pole, 35 KA ,(Outgoing)-01 Nos. (c) MCCB200 Amp, 415 volt, 4 pole, 25 KA ,(Outgoing)-01 Nos. (d) MCCB125 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (e) Digital Multifunction meter with suitable size of CTs. -set of 03(f)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 46 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 300 A and 1 Ph (neutral) of 150 A and comprising of the following :-(a) MCCB200 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming)(b) MCCB125 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-03 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 47 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 300 A and 1 Ph (neutral) of 150 A and comprising of the following :-(a) MCCB160 Amps, Amps 4 pole 415 Volts AC , 25 KA. - 01 No (Incoming)(b) MCCB100 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-03 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 48 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 500 A and 1 Ph (neutral) of 250 A and comprising of the following :-(a) Incoming MCCB 4 pole 400 Amps 36 KA (Adjustable TM type)- 01 No.(b) Outgoing MCCB 4 pole 63 Amps 16 KA( Fixed TM type)- 06 Nos(c) timer astronomical type 16 Amp with one changeover (d) Multifunction meter to measure kWh,V,freq, I etc– – 01 No (e) Indicating lamp LED type one set in incoming phases.(f) CT Coils of suitable ratio-set of 03. (g) Internal wiring with PVC insulated Aluminium conductor multi stranded cable 1100 Volt grade IS 694 marked of min 2.5 Sqmm including all Aluminium lugs complete shall be deemed to be included in quoted rates. |
| 49 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 350 A and 1 Ph (neutral) of 175 A and comprising of the following :- (a) Incoming MCCB 4 pole 250 Amps 25 KA(Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 100 Amps 16 KA( Fixed TM type)- 03 Nos (c) timer astronomical type 16 Amp with one changeover-01 Nos(d) Multifunction meter to measure kWh,V,freq, I etc– – 01 No(e) Indicating lamp LED type one set in incoming phases. (g) CT Coils of suitable ratio-set of 03. (f) Internal wiring with PVC insulated Aluminium conductor multi stranded cable 1100 Volt grade IS 694 marked of min 2.5 Sqmm including all Aluminium lugs complete shall be deemed to be included in quoted rates. |
| 50 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 400 A and 1 Ph (neutral) of 200 A and comprising of the following :- (a) Incoming MCCB 4 pole 320 Amps 36 KA(Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 63 Amps 16 KA ( Fixed TM type)(one spare)- 05 Nos (c) Timer astronomical type 16 Amp with one changeover(d) Multifunction meter to measure kWh,V,freq, I etc– – 01 No(e) Indicating lamp LED type one set in incoming phases. (f) CT Coils of suitable ratio-set of 03. (g) Internal wiring with PVC insulated Aluminium conductor multi stranded cable 1100 Volt grade IS 694 marked of min 2.5 Sqmm including all Aluminium lugs |
| 51 | All as per Ser item No 38.00 here in before but new provision and Aluminium bus bar , 3 ph(RYB) of 500 A and 1 Ph (neutral) of 250 A and comprising of the following :-(a) Incoming MCCB 4 pole 400 Amps 36 KA(Adjustable TM type) - 01 No(b) Outgoing MCCB 4 pole 100 Amps 16 KA ( Fixed TM type) - 02 Nos (c) Outgoing MCCB 4 pole 63 Amps 16 KA ( Fixed TM type)- 04 Nos(d) timer astronomical type 16 Amp with one changeover(e) Multifunction meter to measure kWh,V,freq, I etc– – 01 No(f) Indicating lamp LED type one set in incoming phases.(g) CT Coils of suitable ratio-set of 03. (h) Internal wiring with PVC insulated Aluminium conductor multi stranded cable 1100 Volt grade IS 694 marked of min 2.5 Sqmm including all Aluminium lugs complete shall be deemed to be included in quoted rates. |
| 52 | Supply, Installation, testing and commissioning of LT feeder piller box outdoor type fabricated ofsize 0.6x0.6x0.5M,out of 3.00 mm thick CRCA sheet, CPRI approved complete with powder coating with seven tank process mounted on MS angle frame of size 50x50x6mm, duly grounted with PCC using concrete 1:2:4 type B-1 required with the following-(a)Supply and fixing Aluminium bus bar 200 Amp with coloured heat shrinkable insulated sleeve 415 volts as per IS of suitable size mounted on DMC/epoxy insulator (not than 50mmx50mm conicle type at a maximum interval of 500 mm - set of 03. (b)Supply and fixing MCCB TPN125 Amps 16 KA- 01 No for main incoming complete shall be deemed to be included in quoted rates. |
| 53 | Supply, Installation, testing and commissioning of LT feeder piller box outdoor type fabricated ofsize 0.6x0.6x0.5M,out of 3.00 mm thick CRCA sheet, CPRI approved complete with powder coating with seven tank process mounted on MS angle frame of size 40x40x5mm, duly grounted with PCC using concrete 1:2:4 type B-1 reqd with the following(a)S & F Aluminium bus bar 400 Amp for 3 phase and 200 Amp for Neutralwith coloured heat shrinkable insulated sleeve 415 volts as per IS of suitable size mounted on DMC/epoxy insulator (not than 50mmx50mm conicle type at a maximum interval of 500 mm - set of 03 complete shall be deemed to be included in quoted rates. . |
| 54 | Supply, Installation, testing and commissioning ofoutdoor type cubical panel board of size 1.2x1.2x.05 metre ,outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm grouted with PCC 1:2:4 type B-1 ,frame factory fabricated with front and back openable double door system and cable alloy(Each door hinged with body at 2 places with body and hinges should be welded with body and door) with locking arrangementsand outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar , 3 ph(RYB) of 600 A and 1 Ph (neutral) of 300 A, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011Part-1 andpart -2 type test certificate with not less thanIP-65and breaking capacity 65 KA (Location - RS enclave near Block No 186) comprising of the following :-(a) MCCB320 Amps, Amps 4 pole 415 Volts AC , 36 KA - 01 No (Incoming)(b) MCCB160 Amp, 415 volt, 4 pole, 25 KA ,(Outgoing)-01 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 55 | All as per Ser item No 54 here in before but Aluminium bus bar , 3 ph(RYB) of 400 A and 1 Ph (neutral) of 200 A and comprising of the following (Location - RS enclave near Block No 236) :-(a) MCCB250 Amps, Amps 4 pole 415 Volts AC , 25 KA - 01 No (Incoming)(b) MCCB160 Amp, 415 volt, 4 pole, 25 KA ,(Outgoing)-01 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 56 | All as per Ser item No 54 here in before but Aluminium bus bar , 3 ph(RYB) of 250 A and 1 Ph (neutral) of 125 A and comprising of the following(Location - RS enclave near Block No 187 & Manekshaw enclave near Block No 08) :-(a) MCCB160 Amps, Amps 4 pole 415 Volts AC , 25 KA. - 01 No (Incoming)(b) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (c) Digital Multifunction meter with suitable size of CTs. -set of 03(d)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etccomplete shall be deemed to be included in quoted rates. |
| 57 | All as per Ser item No 54 here in before but Aluminium bus bar , 3 ph(RYB) of 200 A and 1 Ph (neutral) of 100 A and comprising of the following(Location - RS enclave near Block No 192-1, 190-1,183-1, 182-1, 181-1, 157-1, 154-1, Rane encl near block No 45 & BPH colony Near Block No 223-1, 164-1) :-(a) MCCB125 Amps, Amps 4 pole 415 Volts AC , 16 KA. - 01 No (Incoming)(b) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (c) Digital Multifunction meter with suitable size of CTs. -set of 03(d)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates. |
| 58 | All as per Ser item No 54 here in before but Aluminium bus bar , 3 ph(RYB) of 300 A and 1 Ph (neutral) of 150 A and comprising of the following (Location - Rane enclave near Block No 46) :-(a) MCCB200 Amps, Amps 4 pole 415 Volts AC , 25 KA. - 01 No (Incoming)(b) MCCB125 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (b) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-03 Nos. (c) Digital Multifunction meter with suitable size of CTs. -set of 03(d)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 59 | All as per Ser item No 54 here in before but Aluminium bus bar , 3 ph(RYB) of 300 A and 1 Ph (neutral) of 150 A and comprising of the following (Location - BPH colony near Block No 226-1 & 170-1 ):-(a) MCCB200 Amps, Amps 4 pole 415 Volts AC , 25 KA - 01 No (Incoming)(b) MCCB125 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-04 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 60 | All as per Ser item No 54 here in before but Aluminium bus bar , 3 ph(RYB) of 300 A and 1 Ph (neutral) of 150 A and comprising of the following (Location - Manekshaw enclave near Block No 61):-(a) MCCB200 Amps, Amps 4 pole 415 Volts AC , 25 KA - 01 No (Incoming)(b) MCCB100 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-03 Nos. (c) MCCB63 Amp, 415 volt, 4 pole, 16 KA ,(Outgoing)-01 Nos. (d) Digital Multifunction meter with suitable size of CTs. -set of 03(e)Misc items like screws, cable tie, Aluminium cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete shall be deemed to be included in quoted rates. |
| 61 | M & L for earthing complete with galvanisedearth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, burried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nuts and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I (2009) & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GIprotection pipe (light grade), funnel, wire mesh,cast iron cover andframe etc including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with standgrouted in PCC. (iii) On testing after completion if the desired earth resistanceis more than 2 ohmsthe earthing will be redone at no extra cost.(iv) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. |
| 62 | All as per item ser itemNo 61 here in before but for connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel, including taking down old unsv existing earthing ,complete all as specified and as directed. |
| 63 | Supply & fixing of Automatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Three phase, 25 Amps per phase, MCB rating 32Amp, max load 8-12 kw incl circuit copper wire 10 sq.mm.Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS) complete all as specified and directed. Note :- (i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii)The sensor must have the warranty of minimum of 2 years(iii)The test certificate and warranty certificate must be provided by supplier.(iv)Cost of marking description on the box is included in quoted rate. |
| 64 | Supply and fixingfor outdoor end terminationjoint heat shrinkable 1100 Volts for XLPE cable of size 70 to 150 Sqmm 3.5 core complete all as specified & directed. |
| 65 | Supply and fixingfor outdoor end terminationjoint heat shrinkable 1100 Volts for XLPE cable of size 185 to 300 Sqmm 3.5 core complete all as specified & directed. |
| 66 | Dismantling air break gang operated switches vertical/horizontal mounted includinginsulators and operating mechanism for repair/ replacement of broken/worn outcomponents and insulators etc. or carrying to MES store (spare/components for replacement to be provided free by department),complete all as specified & directed. |
| 67 | Dismantling lightening arresters of any type and size,complete all as specified and as directed. |
| 68 | Dismantling of GI earth wire and guard wire from existing OH lines complete all as specified and directed |
| 69 | Supplying and laying un-reinforced precast concrete cable cover, class precast concrete cable cover, class HV,Type 1,flat, size 300mm x 180 mm x 40 mmcomplete all as specified and directed. |
| 70 | Supply and laying3 core XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoued, electric power cable (heavy duty) 11000 volts grade with stranded aluminimum conductor with cross sectional area95 sqmm ,IS 7098marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed.(Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule.) |
| 71 | Supply & laying cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm cross sectional area,complete all as specified and as directed. |
| 72 | Supply & laying cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm cross sectional area,complete all as specified and as directed. |
| 73 | Material and labour for anti climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts, bolts, washers and welding in two halves, made to shape to suit the cross section of the pole complete all as specified and directed. |
| 74 | Supply and fixing pin type, porcelain,vitreous,white or brown or green insulators,11000 volts grade of 150 mm dia ,150 mm height including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nutscomplete all as specified and as directed. |
| 75 | Material and labour for disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball andsocket type, white, brown or green single disc assembly for tension with tension clamps for conductors, suitable for 11000 volts complete all as specified and directed. |
| 76 | Supply and fixing of retro reflective sign board of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 30mm X 30mm X 3mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed.NOTES:- (i) Excavation, earth work, PCC, nuts, bolts, fastners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge. |
| 77 | Material and labour for GI pipe light grade 150 mm dia for road crossing along with pole/culvert /drainage for mechanical protection of cable complete all as specified and directed. |
| 78 | Material and labour for GI pipe light grade 100 mm dia for road crossing along with pole/culvert /drainage for mechanical protection of cable complete all as specified and directed. |
| 79 | Supply and erection in truly verticle position , steel tubular swaged poles 11.00 metre long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-55, providing synthetic enamel aluminium paint over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 metre above the coping of pole starting with black strip,complete all as specified and as directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii)Any description of pole as directed by GE will be printed on each pole without any extra cost. |
| 80 | Material and labour for Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregateas coping of pole and strut , stay around pole etc,complete all as specified and as directed. |
| 81 | Material and labour of PCC 1:2:4 Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete allas specified and directed . |
| 82 | Supplying and fixing of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled red, with letters, figures and conventional skull and bones in signal white colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT line, 25x20cm size complete all as specified and directed. |
| 83 | Supply, install, test and commission polymer lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating complete all as specified directed. |
| 84 | Supply, installing, testing and commissioning of air break gang operated triple switch( GODO) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including pad lock with two keys complete with fuse carrier andHT fuse elementhaving upto 200 Amp rating suitable for HT 11 KV 50 HZ ACsupply including necessary electric connection complete all as specified and directed . |
| 85 | M&L of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats ofaluminum paint complete all as specified and directed. |
| 86 | Schedule of Credit |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail