| 1 | Taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight, mirror light, ceiling light etc complete all as specified and directed. |
| 2 | M&L for Point wiringwith 1.5 Sqmm FRLS-H insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS-H insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision ofearth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass GI screws/modular cover plate as required for mounting switches, sockets, fan regulator etc/modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:- |
| 3 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 4 | One 6A socket point controlled by one switch on independent board |
| 5 | One 6A socket point controlled by one switch on same board |
| 6 | -Ditto- all as per item No 2.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 7 | -Ditto- all as per item No 2.00 above here in before but wiring in existing conduit for the following :- |
| 8 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 9 | One 6A socket point controlled by one switch on independent board |
| 10 | One 6A socket point controlled by one switch on same board |
| 11 | One light point controlled by two No. two way switch complete all as specified and directed |
| 12 | -Ditto- all as per item No 4.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 13 | Taking down old existing unserviceable sub main wiring of any description complete all as specified and directed. |
| 14 | M&L for sub main wiring along with earth wire with FRLS-H insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/inspection covers etc of suitable size but not less than 25mm concealed in wall/floor etccomplete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) |
| 15 | 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) |
| 16 | 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) |
| 17 | 2runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire) |
| 18 | Notes for item No. 2.00 to 7.00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) If any beam/column/Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure.(iii)No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion. |
| 19 | S&F switch piano flush type 6 Amps, one way, 240V, 50Hz, complete all as specified and directed |
| 20 | S&F socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz, complete all as specified and directed. |
| 21 | S&F switch piano flush type 16 Amps, one way, 240V, 50Hz, complete all as specified and directed. |
| 22 | S&F socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz, complete all as specified and directed |
| 23 | S&F electronic socket type fan regulator rotary type in 5 steps of suitable rating as per site requirement, 240V, 50Hz, complete all as specified and directed. |
| 24 | S&F switch piano flush type whitefinish 5/6Amps, single pole two way, 230 volts, 50 hz complete all as specified & directed. |
| 25 | S&F bell push switch flush type 6 Amps, 240V, 50Hz, complete all as specified and directed |
| 26 | S&F electric call bell ding dong type, AC, 240V, 50Hz, complete all as specified and directed |
| 27 | S&F Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as specified and directed. |
| 28 | S&F Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as specified and directed. |
| 29 | S&F Modular Socket,6A-2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed. |
| 30 | S&F Modular Socket6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed. |
| 31 | S&F Modular Socket Type fan regulator step type in 5 steps of suitable rating as per site requirement, 240V, 50Hz complete all as specified and directed. |
| 32 | S&F Modular Bell push 6A 1 module, 240V, 50Hz complete all as specified and directed. |
| 33 | S&F of Modular blank plate 1 module complete all as specified and directed. |
| 34 | S&Fceiling rose in poly carbonate 3 terminal brass, flush type 6 Amps, 220 volts AC, ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed. |
| 35 | S&F in replacement of Lamp holder, angle type with metal ring, PVC/ Polycarbonate body type B-22 with back plate, complete all as specified and directed. |
| 36 | S&F in replacement Decorative wall light fitting with brushed nickel/stainless steel base, made out of polycarbonate/glass diffuser suitable for and including 9 Watt WW/CDL LED Bulb fixed on wall and making electrical connection complete all as specified and directed. |
| 37 | S&F in replacement of old unserviceable LED bulb 12 watt, 6500K, 1200 lumen,ISI marked, as per standard specifications,complete all as per specified and directed. |
| 38 | S&F in replacement of T-8, LED battentype body pre-wired with bipin holders, connector block complete with all accessories including 20 Watt (4 feet) retrofit LED tube with Polycorbonate body, full white and connecting up with PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. |
| 39 | S&F in replacement of old unserviceable LED T5 tube light fitting 20 watts with polycarbonate housing and polycarbonate diffuser with integrated electronic driver with all accessories including connecting up with PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. |
| 40 | S&F in replacement of old unserviceable LED mirror light fitting Integral slim LED batten Integral 9/10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with PVC insulated and PVC sheathed twisted two core wire of suitable size complete all as specified and directed. |
| 41 | S&F in replacement of recessed mounted LED panel light 2\"x2\" size, 36 watts, full white/warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP/Amstrong/grid false ceiling complete with all fixing accessories including making electrical connection with PVC insulated and PVC sheathed twisted two core wire of suitable size complete all as specified and directed. |
| 42 | S&F in replacement LED bollard light 9/10 Watt CDL/WW made out of pressure die cast powder coated housing with PC diffuser with LED as a source light including making electrical connection complete all as specified and directed. |
| 43 | S&F in replacement of surface/recessed mounted LED panel light 4\"x1\" size, 36 watts, full white/warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP/Amstrong/grid false ceiling complete with all fixing accessories including making electrical connection with PVC insulated and PVC sheathed twisted two core wire of suitable size complete all as specified. |
| 44 | S&F in replacement of slim round/square recessed/surface mounting LED down light 5/7 W suitable size, with aluminium die-cast body, finish with drop down PC diffuser warm/full white with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 45 | S&F in replacement of slim round/square recessed/surface mounting LED down light 18/22 W suitable size, with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 46 | S&F in replacement of ventilating/PVC exhaust fans fancy square type 225/250 mm sweep with plastic fiber body 230 Volt AC, single phase 900 RPM complete with plastic louvers and including making suitable size of holes in wall for fixing the fan & making good including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed. |
| 47 | S&F in replacement of LED street/security light fitting 25 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 40 mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps (02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washersand provision of 3 core PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. |
| 48 | S&F in replacement of old unserviceable LED Flood light fitting 50 watt capacitywith SMD LED pressure die-cast aluminium housing with reflector including making electrical connection with PVC insulated and PVC sheathed twisted three core wire of suitable size complete all as specified and directed. Note :- The Quoted rate is deemed to be included for installation of light fitting at any height including necessary T & P and safety equipments. |
| 49 | S&F in replacement of old unserviceable LED Highbay light fitting 100 watt capacity with PDC aluminium housing with reflectorincluding making electrical connection from ceiling rose to light fitting complete all as specified and directed. |
| 50 | S&F in replacement of old unserviceable LED Post Top Lantern light fitting 30/35watt with LED as source light & tranparent diffuser and fixing arrangement on new GI Pipe medium grade of dia 40 mm duly grouted on wall/brick pillar with the help of cement mortar including making electrical connection with PVC insulated and PVC sheathed twisted three core wire of size 1.0 sqmm complete all as specified and directed at site. |
| 51 | S&F in replacement of old unserviceable Post Top lantern globe type light fitting of capacity 1x7/8 watts with B-22 base LED bulb, transparent polycarbonate diffuser and fixing arrangement on new GI pipe of 25/40 mm dia medium grade of length 1.5m duly grouted on ground/wall/brick pillar with the help of cement mortar including making electrical connection with PVC insulated and PVC sheathed twisted three core wire of size 0.5 sqmm fromjunction box to light fitting complete all as specified and directed at site. |
| 52 | S&F in replacement PVC/DK Thermoplastic cable junction boxes IP 49 or more with metric knockouts for cable entry, weather proof suitable for outdoor installation for Gate light and Post top lantern, fixed on wall with screw & rawal plug and on GI Pipe wth suitable size MS clamp and Nut-bolts,washer of suitable size complete including one connector block three terminals and PVC cable gland 02 Nos for incoming and outgoing cables with provn of 01 nos single pole MCBs 10-32 amps inside the box including taking out/down existing unserviceable junction box of any description complete all as specified and directed at site. |
| 53 | S&F in replacement of power unit MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. |
| 54 | S&F in replacement of MCCB/MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar of capacity 200 amp, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately. |
| 55 | S&F in replacement of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar of suitable capacity, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note: MCBs shall be measured and paid separately. |
| 56 | All as per item No 45 here-in-before but SPN, 8 way, 230 V, 1 phase, ACNote:MCBs shall be measured and paid separately. |
| 57 | All as per item No 45 here-in-before but SPN, 4 way, 230 V, 1 phase, ACNote:MCBs shall be measured and paid separately. |
| 58 | S&F MCCB 100A, 25 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed. |
| 59 | S&F in replacement of MCB 63 Amp, 10 KA, TPN,\"C\" curve, 415 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 60 | S&F in replacement of MCB 40A, 10 KA, SPN, \"C curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 61 | S&F in replacement of MCB 10 to 32A, 10 KA, single Pole, \"C curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 62 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron, UL listed, CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit (resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7. The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000kg load bearing capacity (Size : 270x240x200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including suitable dia of medium grade GI pipe upto 7 mtr incl cutting and chases on wall and floor complete all as specified and directed.Note:The rate quoted above shall be deemed to be included for excavation and earth work, refilling, removal of surplus earth and making good the surface around chemical earthing. |
| 63 | M&L for dismantling the existing switch board, disconnecting the switch/ sockets etc and replace the damaged hylum sheet with 3mm thick phenolic laminated hylum sheet of size 9\" X 11\" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers alongwith fixing the previous fixed switch/ sockets etc complete all as specified and directed. |
| 64 | M&L for dismantling the existing switch board, disconnecting the switch/ sockets etc and replace the damaged hylum sheet with 3mm thick phenolic laminated hylam sheet of size 8\" X 5\" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers alongwith fixing the previous fixed switch/ sockets etc. complete all as specified and directed. |
| 65 | M&L for dismantling the existing switch board, disconnecting the switch/ sockets etc and replace the damaged hylum sheet with 3mm thick phenolic laminated hylam sheet of size 5\" X 5\" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers alongwith fixing the previous fixed switch/ sockets etc complete all as specified and directed. |
| 66 | S&F in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 6 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line /energy meter/DB etc complete all as specified and directed. |
| 67 | - Ditto - all as per item No 56 but of size twin core 4 sqmm |
| 68 | Taking down old unserviceable ceiling fan & S&F BLDC Ceiling fan complete with three blades down rod, accessories 230 V, 1200mm sweep, BEE 5 star white/warm white complete all as specified and directed.Note: Old Ceiling fan to be deposited in MES store Yard |
| 69 | Taking down old electric water heater & Supply and fix in replacement electric water heater,storage type steel body with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated, ISI Marked, 240 V, 50 Hzcomplete with all accessories such as safety valve, thermostate, NRV, Hot and cold water connection pipe all as specified and directed.Note: Old Water heater to be deposited in MES store Yard |
| 70 | S&F Exhaust fan Steel body AC single phase 230/240 Volt of size 300 mm sweep 900 RPM complete with louvers including making whole on wall to fix exhaust fan and grouting of nut bolts etc and making good the disturbed sufaces of wall all as specified and directed . |
| 71 | S&F Heavy duty Exhaust fan Steel body AC single phase 230/240 Volt of size 450 mm sweep 1400 RPM, double bearing with air delivery not less than 1500 CMH complete with louvers including making whole on wall to fix exhaust fan and grouting of nut bolts etc and making good the disturbed sufaces of wall all as specified and directed. |
| 72 | Supply, fix and fabricate 18mm thick prelaminated Particle board , interior grade, with screws & hinges to timber/wood/welded to angle iron frame for meter box, coloured and patteren as approvedincluding hinge, locking arrangement and stainless steel bright finish handle complete all as specified and directed. |
| 73 | S&F rotory type switch flame proof with termination box in LM6, 16 A single pole 250Volt complete all as directed including the quoted rate is deemed to be include the price of GI sunken box suitable for flame proof rotary switches, sockets etc of any sutable size & shape.(i)The quoted rate is deemed to be included rate of dismantling of existing point of any type including fittings & fixtures complete.(ii) The contractor shall be visit the site before quoted the rate. |
| 74 | S&F in replacement, flame proof SPN distribution box 4/6 way outgoing for isolators MCBs and ELCBs flame proof suitable for gas group I, IIA, IIB as per IS-2146 of 1961, Temp class T-3 having degree of protection IP-65 as per IS-2147 of 1962 cast aluminium alloy LM-6/CI construction light grey epoxy shade No-631 of IS -5 power coating having provision for one number internal and two nuimber external screws for earthing, also having \"O\" ring endless neoprene rubber gasket, fixed to wall mounted, hardware in stainless steel construction having one number incoming suitable for 16x2 core XLPE armoured cable and 8 Nos out going cable entry from bottom side along with 200 Amps bus bar also internally wired upto terminals for incoming and out going cables including incommer 32 Amps MCB-01 No and out going SP MCB-04 Nos complete all as specified and directed. |
| 75 | S&F in replacement, LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, LED tube light fixtures driver, holders, connector etc with all accessories pre-wired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 76 | S&F in replacement, flame proof LED light fitting 1x16 Watt, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass, LED tube light fixtures driver, holders, connector etc with all accessories pre-wired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 77 | S&F in replacement of piano switch 5 Amp only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 78 | S&F in replacement of piano switch 15 Amp only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 79 | S&F in replacement of socket outlet 6 Amp, 2/3 pin only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 80 | S&F in replacement of socket outlet 5/16 Amp, 3/5 pin only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 81 | S&F in replacement of step type fan regulator in 5 steps only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 82 | S&F in replacement of socket type fan regulator rotary type in 5 steps only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 83 | S&F in replacement of bell push only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 84 | S&F in replacement of T5 light fitting 20 watts polycarbonate housing nd polycarbonate diffuser with integrated electronic driver only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 85 | S&F in replacement ofcapacitor of 2.5 MFD only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |
| 86 | S&F in replacement of LED Bulb 9 watt only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper complete all as specified and directed. |