| 1 | Demolition of brick work or stone boulder masonery, built in cement mortor including all quoins, arches, pillars etc, complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position, not otherwise specifically provided for, complete all as specified and directed. |
| 3 | M&L for brick work with sub class \"B\" old size brick, straight or curved on plan exc 6 mtr mean radius but in CM 1:4, half brick thick, complete all as specified and directed. |
| 4 | M&L for brick work with sub class ‘B’, old size bricks, straight or curved on plan exc 6 mtr mean radius, built in CM 1:4, complete all as specified and directed. |
| 5 | All as per serial item No. 4.00 here-in-above but except bricks. |
| 6 | Taking down cement plaster of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 7 | M&L for 15mm thick rendering in CM 1:4 on fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 8 | Supply only integeral water proofing compound, complete all as specified and directed. |
| 9 | S&F in replacement of 110mm bore PVC (SWR) pipes in any length with rubber ring joints, laid in floors/ trenches or fixed to walls with MS/ PVC clamps of suitable size at any height, complete all as specified and directed.Note :- Rates for necessary scaffolding, ladder or other means shall be deemed to include in the quoted rates. |
| 10 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping, kneelers, bed block including necessary from work, complete all as specified and directed. |
| 11 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 12 | M&L for waling of random rubble stone masonry, built in cement motar 1:6, uncoursed, well bounded, bedded and solidly hearted, complete all as specified and directed. |
| 13 | All as per serial item No. 12.00 here-in-above but except stones. |
| 14 | M&L for raised pointing to random rubble stone masonry in CM 1:4, complete all as specified and directed. |
| 15 | Providing precast cement concrete bonders in cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates), set in CM 1:6, complete all as specified and directed. |
| 16 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels, drains etc, complete all as specified and directed. |
| 17 | M&L for 50mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection, laid in alternate ways (not exc 2.0 Sqm each) and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 18 | Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided for, complete all as specified and directed. |
| 19 | M&L for RCC 1:1.5:3 type A-1 (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5 mtr span, complete all as specified and directed. |
| 20 | M&L for RCC 1:1.5:3 type A-1 (using 20mm graded crushed stone aggregates) as slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including 15mm thick plastering in CM 1:4 with water proofing compound,laid/made to slope as in RCC roof surfaces, complete all as specified and directed. |
| 21 | Use and waste of formwork to rough finished concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 22 | Use and formwork to edges of rough finished concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, complete all as specified and directed. |
| 23 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 24 | M&L for mild steel TMT bars, 6-8mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 25 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 26 | Fixing only mild steel work as in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire & similar work, complete all as specified and directed. |
| 27 | M&L for mild steel angle iron/ flat iron work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work, conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed. |
| 28 | S&F in repairs/ replacement of galvanised 2 strand steel barbed wire of 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc, complete all as specified and directed. |
| 29 | S&F in repairs/ replacement of concertina coil punched type (including spike and handle) with 50/51 turns and dia 600mm having a 2.6mm dia core wire of high carbon spring steel of high tensile strength. The punched tape and core wire are electro galvanized to provide protection against out door exposure. The punched tape is mechanically crimped over the cover wire and then formed into a coil at various parts of the periphery of the coil steel clips cannect the individule turns of the coil to each other so that it opens up like an accordion. The weight of each coil will be 9 Kgs (+/- 5%) without packing material and coil length 7 to 8 mtr when opened up. Each coil wound with bituminized hession cloth for providing protective coating, complete all as specified and directed. |
| 30 | Excavation in post holes (or similar holes) each not exceeding 0.50 Cum in any type soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering, and removing surplus soil, complete all as specified and directed. |
| 31 | M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foudation for fencing post, filling in and mass concrete, complete all as specified and directed. |
| 32 | S&F mild steel bolts, purpose made with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 30cm long and dia of neck exceeding 12mm but not exceeding 20mm, complete all as specified and directed. |
| 33 | S&F in repairs/ replacement of chain link MS galvanised fencing of size 50mm x 50mm, any type as per site requirement, complete all as specified and directed. |
| 34 | M&L for preparation of new or previously steel surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enemel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 35 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in floors, complete all as specified and directed. |
| 36 | M&L for machine pressed concrete interlocking paver blocks, glossy finish, any shape and size, confirming to IS:15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment, complete all as specified and directed. |
| 37 | M&L for machine pressed concrete interlocking paver blocks, glossy finish, any shape and size, confirming to IS:15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment, complete all as specified and directed. |
| 38 | M&L for chequered cement concrete tiles of size 30cm x 30cm x 25mm thick each, glossy finish, set, jointed and pointed in neat cement slurry as in floors with grey cement and pigment, laid over and including 20mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 39 | M&L for sand cushoning bed, filling under floors or paver blocks including spreading, levelling, watering if required, complete all as specified and directed. |
| 40 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |