| 1 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation, shafts, wells cesspits, manholes, pier holes etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 2 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 3 | Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 4 | M & L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 5 | Demolition of bricks work or stone/boulder masonary, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete aritcles, complete all as specified and directed. |
| 6 | Taking down cement plaster on brick/concrete surfaces of any description in any position incl racking out joints, hacking for key, scrubbing down with water etc and removing rubish off the premises, complete all as specified and directed. |
| 7 | M&L for brick work with fly ash brick, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:4), complete all as specified and directed. |
| 8 | M&L 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces finished surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 9 | M & L for preparation of newly plastered surfaces of walls and applying two coats of 100% acrylic weather proof exterior emulsion paint of approved colour and shade, alkali & fungal resisatance (over a coat of exterior emulsion primer) as per manufacturere\"s instructions, complete all as specified and directed. |
| 10 | M & L for 40mm thick PCC (1:2:4) type B-0 (using 20mm graded crushed stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary formwork, polythene film, 50 micron thick, laid on and including a coat of bitumen primer @ 0.30 to 0.50 Kg per Sqm, complete all as specified and directed. |
| 11 | M&L for PCC (1:2:4) type B-0, (using 12.5mm graded crushed stone aggregate) as in copings, fixing of angle posts etc, including necessary form work, complete all as specified and directed. |
| 12 | M&L for RCC (Nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregrate) as in columns, bands, beams etc, complete all as specified and directed. |
| 13 | Use and waste of formwork to edges of concrete flats, sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 20cm wide rough finished surfaces of concrete, complete all as specified and directed. |
| 14 | M & L for mild steel TMT bars 10mm dia (Grade not less than 500D), cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 15 | M & L for mild steel TMT bars 6 to 8mm dia (Grade not less than 500D), cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 16 | M & L for providing precast cement concrete louvres and jallies, 25mm thick (measured solid) in PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) including all mouldings but excluding frame, set in CM (1:4), complete all as specified and directed. |
| 17 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering, doors, etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing FE-290, Gde E-165, complete all as specified and directed. |
| 18 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide, zinc crome primer, complete all as specified and directed. |
| 19 | M&L for complete removal of existing treatment of old external surfaces of wall and applying two coat of water based acrylic weather proof exterior emulsion paint over a coat of exterior emulsion primer, complete all as specified and as directed. |
| 20 | Demolition of reinforced cement concrete(reinforcement cut as required to facilate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 21 | Dismantling posts or struts any type including taking out embedded portion in concrete/RCC, any section and making good disturbed surfaces, complete all as specified and as directed |
| 22 | S&F MS posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 (Gde E-165), complete all as specified and directed. |
| 23 | S&F in repair for 960mm dia barb (unstretched) conseczal super razor punched tape (SRPBT) aluminium base helix coil with and including necessary for securing, fixed on wall with existing angle iron Y shaped, with horizontal rainforced barbed wire tied with GI staples and GI fixing clips to certain horizontal, complete all as specified and directed. Note (i) : No of circles - 51 turns per coil, weight of each coil with hessian pack 13 Kg (+ 0.5), coverage per coil - 6 RM, central core wire :- Made from 2.5mm dia (+ 0.05mm) GI - H.T.S.S wire as per IS -4454 Part l grade SM UTS : 1600N / Sqmm with zinc coating of 240 gm per sqm, galvanized as per IS-2629, Razor punched strip - Razor punched tape is CONSEC-ZAL steel comprising of aluminium base with zinc alloy @ 150 gm per Sgm confirming to ASTM A-792 / A- 792M with additional primer treatment of epoxy / polyurethane of 2-m micron thick and final paint top coat of certified green shed (BSL 139) by hot dipping process of 15 micron thick, length of barb 23.5mm (+1 mm), width of barb 18.6 mm (+ 1mm), centre to center pitch 36mm (+ 1mm), centre width 7.4 mm (+ 1mm), GI fixing accessories \"C\" clip 2mm wire diameter, 40mm long, 15mm center dia \"U\" clip 1mm thick, 28mm straightened length, \" J\" clip:- 31mm length, 8mm width, 1mm thick.(ii) Running length of the fencing shall be measured for payment purpose.(iii) Barbed wire shall be measured for paid seperately. |
| 24 | S & F in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 25 | M & L for preparation of old painted steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (1st grade quality), complete all as specified and directed. |
| 26 | Note: An amount of Rs.23,720.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |