| 1 | Supplying, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 120 Sq mmincluding taking down old unserviceable cable complete all as specified and directed. |
| 2 | All as per BOQ srl item No.1.00 here-in-above but of size 3.5 core 95 Sqmm complete all as specified and directed. |
| 3 | All as per BOQ srl item No.1.00here-in-above but of size 3.5 core 70 Sqmm complete all as specified and directed. |
| 4 | All as per BOQ srl item No.1.00here-in-above but of size 3.5 core 25 Sqmm complete all as specified and directed. |
| 5 | All as per BOQ srl item No.1.00here-in-above but of size 4 core 16 Sqmm complete all as specified and directed. |
| 6 | All as per BOQ srl item No.1.00here-in-above but of size 2 core 6 Sqmm complete all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soilcomplete all as specified and directed. |
| 8 | All as per BOQ srl Item No. 7.00 here-in-above but for depth exceeding 1.50 m and not exceeding 3.00 m complete all as specified and directed. |
| 9 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soil completed all as specified and directed |
| 10 | Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soil complete all as specified and directed. |
| 11 | M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of sand cushioning after punning down i.e 18cm shall be measured for payment purpose only |
| 12 | M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed. |
| 13 | S&F GI tubing 80 mm bore light grade galvanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position including taking down existing one complete all as specified and directed. |
| 14 | All as per BOQ srl item No. 13.00here-in-above but of size 50mm bore complete all as specified and directed. |
| 15 | All as per BOQ srl item No. 13.00here-in-above but of size 40mm bore complete all as specified and directed. |
| 16 | Restretching properly and tightening ACSR conductor including rebinding aftes straining the singleconductor on LT pole of any size replacing of jumpers if necessary complete all as specified and directed. |
| 17 | S&F in replacement LT spacer 02 way FIX type made out of PVC materialand suitable to work on 1100 volts fixed between 02 conductors in any position along the LT line for any size of conductoralong the feedercomplete all as specified and directed. |
| 18 | S&F in replacement LT spacer 05 way spiral type made out of PVC materialand suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductoralong the feedercomplete all as specified and directed. |
| 19 | M&L for making bore to road/cement path/hard standing for providing GI pipe 40/50/80 mmboth end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed. |
| 20 | Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & F end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm complete all as specified and directed. |
| 21 | All as per BOQ srl item No.20.00 here-in-above but of size 70 to 150Sqmm complete all as specified and directed. |
| 22 | All as per BOQ srl item No.20.00 here-in-above but of size 25 to 50Sqmm complete all as specified and directed. |
| 23 | S&F joint kit in replacement for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size185 to 300 Sqmm complete all as specified and directed. |
| 24 | All as per BOQ srl item No.23.00 here-in-above but of size 70 to 150Sqmm complete all as specified and directed. |
| 25 | Taking down/out old Street light of any type / wattage and Supply and fixing LED street light fittings 120 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type havingpower factor >0.90 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges,necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm for connection complete all as specified and directed . |
| 26 | All as per BOQ srl item No. 25.00 here-in-above but for 90 watt complete all as specified and directed. |
| 27 | All as per BOQ srl item No. 25.00 here-in-above but for 60 watt complete all as specified and directed. |
| 28 | All as per BOQ srl item No. 25.00 here-in-above but for 35 watt complete all as specified and directed. |
| 29 | S&F in replacementLED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 30 | S&F in replacement junction box thermoplastic polycarbonate enclosure, shock proof, IP65/IP66 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands of size 250x200x100mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals with andincluding 01No. 10Amp MCB 10kA duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size at any location complete all as specified and as directed |
| 31 | S&Fincluding taking down LED garden light fitting with LED bulb upto 9 watt with clear acrylic cover in top section with IP 43 protection including all electrical connection with GI pipe light grade upto 90 cm including foundation complete all as directed by Engr in Charge. |
| 32 | S&F in repairs MCCB 63 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 33 | S&F in repairs MCCB 100 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 34 | S&F in repairs MCCB 125 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 35 | S&F in repairs MCCB 160 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 36 | S&F in repairs MCCB 200 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 37 | S&F in repairs MCCB 250 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 38 | S&F in repairs MCCB 400 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. . |
| 39 | S&F in repairs MCCB 630 Amp, 4 pole 50 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 40 | S&F in replacement on load change over switch 415 Volt 630 Amp 4 Pole in open execution handle opearted complete all as specified and directed. |
| 41 | Repair/Maintenance of any type any size LT/HT panel by opening all incoming and outgoing LT/HT cable connection and reconnecting the LT/HT cable in proper manner by changing all burnt lugs and proper insulation of all nacked cable incl cleaning of panel with blower from inside and removing all grass and bushes around the panel up to 2 mtr distance incl Painting of panel one coat of synthetic enamel paint of grey colour, welding work for repair of broken hinges, doors, complete all as specified and directed. |
| 42 | S&F in replacement Bus Bar Chamber of size 45 x 45 x 30 cm suitable of 3 phase 433 Volts outdoor type and neutralmade out of 3.15 mm thick M S Sheet with 100 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and angle iron stand of size 40 x 40 x 6mm frame grouted in ground with PCC foundation 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connections,lugs and cable gland including 2 coat of paint over a coat of red oxide primercomplete all as specified and directed. |
| 43 | All as per BOQ srl item No. 42.00 here-in-above but of size 60x60x45cm with 200Amps busbar complete all as specified and directed. |
| 44 | All as per BOQ srl item No. 42.00 here-in-above but of size 60x60x45cm with 400Amps busbar complete all as specified and directed. |
| 45 | S&F including taking down LT feeder pillar panel weather proof outdoor type double door fabricated cout of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035( Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed ,dust & vermin proof,confirming to degree of protection IP-55,gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cyllendrical panel locked .The panel shall be provided with alluminium bus bars,electrolytic grade of adequate rating or as specified below.The bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable,non hygroscopic,SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated coper conductors cables of suitable size properly tagged and secured..The panel shall be provided with digital Voltmeter/Ammeterwith cast resign CTs & RYB LED indicating lamps at incoming.Sthe panel shall be provided with heavy duty steel cable glands of adequate size for incoming & ali outgoing cables..the panel shall be provided with manufacturer name plate,skull & bone danger notice board etc. the panel shall be provided with 04 numbers 50mmx50 mmx6mm thick angle iron supports . duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth at per site requirement.All MCCBs shall be provided with spreader links with phase seperator on both sided and suitable extended rotary handle for incoming MCCB complete all as specified and as directed.. the panel shall be provided with and including the following accessories : |
| 46 | (a) Aluminium bus bar -500 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i)MCCB 4P 315 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 Nos(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv)LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i)MCCB 3P -250Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection-01 Nos(ii)MCCB 3P -100Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-03Nos (iii)MCCB 3P -63Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01Nos |
| 47 | All as per BOQ srl item No-46.00 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -400 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i)MCCB 4P 250 Amps 25 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 Nos(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv)LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i)MCCB 3P -100Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-03Nos (ii)MCCB 3P -63Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01Nos |
| 48 | All as per item No-45 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -400 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) On load Changeover Switch 4P 250 Amps- 01 No, MCCB 4P 250 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv)LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i)MCCB 3P -200Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection-01 No(i)MCCB 3P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection-01 No(ii)MCCB 3P -100Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02Nos |
| 49 | All as per BOQ srl item No-45.00 here-in-above but Panel with the following accessories are under. (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 315 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv)LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i)MCCB 3P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-04Nos(iii) MCCB 3P -100Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01No |
| 50 | All as per BOQ srl item No-45.00 here-in-above but Panel with the following accessories are under. (a) Aluminium bus bar -800 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 630 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv)LED Indicating lamp R,Y, B-01 setOUTGOING:-(i)MCCB 3P -315Amps 36 KA breaking capacity with fixed thermal & fixed magnetic over load protection-01 No(ii)MCCB 3P -250Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02Nos(iii) MCCB 3P -200Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02Nos |
| 51 | M&L in replacement earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and includinggalvanized earth lead strip 32X6 mm size upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and panel all as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,upto7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed.Note : if desired earth resistance is not found then entire earthing shall be re-done by Contractor without accruing any extra cost to the Govt. |
| 52 | M&L for cement concrete 1:3:6 type C-2 using (40 mm graded mechanically crushed stone aggregate) in foundation filling of poles/stays/plinths etc complete all as specified and directed by Engineer-in-Charge. |
| 53 | M&L for cement concrete 1:2:4 type B-1 using (20 mm graded mechanically crushed stone aggregate) in coping of poles including form work whereas required as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 54 | M&L for 15 mm thick rendering on fair face/other than fair face brick work or concrete any surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 55 | M&L for spreading/levelling/compacting 40mm graded mechanicallycrushed stone aggregate in layer not exceeding 150mm thick each layer around the transformer at sub station complete all as specified & directed. |
| 56 | M&L for spreading/levelling/compacting 20mm graded crushed stone aggregate in layer not exceeding 150mm each layer complete all as specified & directed. |
| 57 | Taking down existingSteel/RCC pole 9 metre longcomplete all as specified & directed. |
| 58 | M&L for true vertical steel tubular, swaged welded pole conforming to IS-2713 part II , type 410 SP 31, 9 metre long complete with mild steel base plate of 6 mm thick of size 300mm X 300mm, finial taper plug, cap, bolts, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bituminious paint for embeded portionin concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & nubmering of pole complete all as specified & directed.Note:-Excavation, earth workandPCCshall be measured and paid separately. |
| 59 | S&F in replacement street light GI pipe bracket 40mm dia 1.50m length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc, complete all as specified and directed. |
| 60 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor with inner sheathing of PVC tape and overall PVC sheathed in service connection flat of size 6 sqmm solid aluminium conductor complete all as specified & directed. |
| 61 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor with inner sheathing of PVC tape and overall PVC sheathed in service connection flat of size 10 sqmm solid aluminium conductor complete all as specified & directed. |
| 62 | M&L in Replacement of PVC insulated copper (flexible) conductor 1.5 Sqmm 3 core and connected to street light complete all as specified & directed. |
| 63 | S&F in Replacement of heating element 2.0 KW for 25/35/50ltrs capacity of existing shape/size geyser ISI marked.complete all as specified and directed. |
| 64 | S&F in Replacement of thermo static switch of geyser of existing make for 25/35/50 ltrs complete all as specified and directed. |
| 65 | S&F in replacement hot & cold water PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed. |
| 66 | Taking old unserviceable PVC body air freshnerand supply and fixing PVC body air freshner 250 mm sweep single phase 230 volts including louvers and fixing arrangement as per site requirement complete all as specified and directed. |
| 67 | S&F steel body exhaust fan250/300 mm sweep single phase 230 volts including flap and fixing arrangement as per site requirement including taking down old fan complete all as specified and directed. |
| 68 | S&F steel body body exhaust fan 450 mm sweep single phase 230 volts including lovers and fixing arrangement as per site requirement including taking down old fan complete all as specified and directed. |
| 69 | M&L for Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exceeding 60 mtr complete all as specified and directed.Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tenderer for single operation only |
| 70 | M&L for trimming of tree branches (touching HT/LT OH line) upto 10cm girth at any height carefully taking shutdown including suitable disposal of cut of tree branches as in repair complete all as specified and directed.Note:- Tools & plants including safety measures equipments like belt,ladder & ropes etc shall be arranged by the contractor at their own cost. |
| 71 | Taking old unserviceable existing board and supply and fixing of new 3D acrylic boardof size of (5Mx0.15Mx1M)(LxBxH) including angle iron rectangular cuboid structure/frame of blue colour in back ground and white colour projected LED light capital letter of \"MES COMPLAINT CELL\" letter of Size not less than 35 CM and GE (AF) AMBALA\" letter of size not less than15 CM and fixed on surface of angle iron legs with PCC foundation of existing location complete all as directed. |
| 72 | All as per BOQ srl item No-71.00 here-in-above but letter ESC POWER HOUSE,GE (AF) AMBALA. |
| 73 | M&L for cleaning and preparation of surfaces of HT/LT steel tubular poles(any size) with emery paper, filling the voids with suitable filler materials and applying two coats of aluminium paint over & including one coat of zinc oxide primer to poles, cross arms, brackets, hooks, junction box, stay clamps with and including making blue & orange(AF pattern) strip 30cm wide (5 Nos) upto 1.5 mtrs from PCC coping and marking the numbering on poles with synthetic enamel paint complete all as specified & directed. |