| 1 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 2 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 3 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 4 | Dismantling of stone slabs and tiles laid,bedded and pointed in any mortar of any description or thickness in floors, aprons etc all as directed by Engineer-in-charge. |
| 5 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 6 | Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., complete all as specified and as directed. |
| 7 | Demolition of (Reinforced) Concrete of any description and in any position not otherwisespecifically complete all as specified and as directed |
| 8 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground in Concrete, brick work masonry etc complete all as specified and as directed. |
| 9 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 10 | M&L Plain Cement Concrete type C2 (1:3:6) using 40 mm graded aggregate) in Foundation, Filling and Mass Concrete (bed and side of gully trap), complete all as specified and as directed. |
| 11 | M&L fly ash bricks pulverizes using class designtion 75 (kgf/cm2) bricksstraigth or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed. |
| 12 | M&L Brick Work using old bricks obtained from demolition, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4 EXCEPT BRICKS, complete all as specified and as directed.Note:- Serviceable bricks retrived from demolition item shall be reused. |
| 13 | S&F Mild steel angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410-O or Fe-310-O complete all as specified and directed. |
| 14 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut of 11 to 15mm dia, and 5cm to 10cm long complete all as specified and directed. |
| 15 | S&F PVC coated chain link fencing mild steel galvanised 3.00mm dia (minimum weigth 3Kg/Sqm) of wire and spacing 75mm x 75mm including line wires to any standards, rails and straining bolts including provision of binding wire as in repair complete all as specified and directed.Note :- Line wire and bolts/nuts shall be measured and paid separetaly under relevant item of theis schedule |
| 16 | Supply onlyMild steel round Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith galvanised Steel Wire not less than 0.90 mm and stapleas in line wirecomplete all as specified and as directed. |
| 17 | M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed. |
| 18 | M&L Rendering 15mm thick in 1:4Cement Mortar on fair faces of brick work or concrete surfaces finished the surfaces even and fair complete all as specified and directed |
| 19 | M&L Rendering 15mm thick in CM (1:4) on other than fair faces of brick work or concrete surfaces finished the surfaces even and fair without using extra cementcomplete all as specified and directed complete all as specified and directed. |
| 20 | M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed. |
| 21 | M&L Preparing new Surfaces of Walls and applying Two Coats of Cement Base Paintover a coat of primer complete all as specified and as directed. |
| 22 | M&L complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Cement based Paint over 10 cm width or girth over a coat of primer, complete all as specified and as directed. |
| 23 | M&L for preperation of old wall plastered surface and applying one coat of cement base paint complete all as specified and directed |
| 24 | M&L Preparing new plaster surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work/new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 25 | M&L Complete removal of old decorated surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work/new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 26 | M&L for preparation of old plastered surfrace and applying one coats of weather proof exterior emulsion paint over a coat of primer(Apex Ultima or equivalent) with approved colour and pattern complete all as specifiedand directed |
| 27 | M&L Mild steel TMT Bars 10mm dia and over cut to length bent to shape required includiing cranking bending spirally for hooping for coloumns hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia and securing with clips complete all as specified and directed. |
| 28 | M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed. |
| 29 | M&L Cement Concrete 1:2:4 type B1 (using 20mm graded stone agg) as in copings kneelers, apex stones, bed plates kerbs or similar work complete all as specified and directed |
| 30 | M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in beam, lintel beam, coping etc complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 31 | M&L for RCC (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate)as in Columns, pillars, piers, posts and struts and the like complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 32 | M&LUse and waste of Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, (upto 04 storey high of building) complete all as specified and as directed. |
| 33 | M&LUse and waste of Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, upto 04 storey high of building)complete all as specified and as directed. |
| 34 | M&LProviding precast reinforced cement concrete 1:2:4 type B-0 (using 12.50mm graded stone aggregate) as inlouvres and jallies, 50mm thick (measured solid), including all mouldings, reinforcement etc and set in cement mortar 1:4 complete all as specified and directed |
| 35 | S&F in repair galvanised, 2 strand steel barbed wire 2.24 mm dia barbed with 2.00 mm dia barbs at 75mm spacing staining and fixing to any standard rails and straining bolts including securing or typing at corssing with and provision of galvanised mild steel wire stapples or steel pins etc all as specified and directed (each line of wire to be measured) |
| 36 | S&F Concertina coil fencing with punched tape concertina coil 600mm dia openable length (total length 90 mtr) having 50 Nos rounds per 6 meter length upto 3.2meter height of wall with iron angle \"Y\" shaped placed 2.5 to 3.5m apart and stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbes and GI clips to retain horizontal including necessary bolts or GI barbes wire tied to angle iron, spring core, (2.5 mm thick) wire of height tensile strength of 165 Kg/Sq mm with tape (0.52 mm thick) weight 43.478 gm/meter asin repair all complete as per direction of Engr-in-Charge |
| 37 | M&L Framed Work such as hung as gates including pintle hinges,stops, hand-made sliding bolts etc ,Grills, Gratings. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 38 | All as item No. 37.00 mentioned here-in-before but for ornamental and intricate design |