| 1 | Material and labour for servicing of 2 Nos 2 HP booster pumps, 230V by checking functionality, abnormality, cleaning, proper alignment of fan covers, tightening nut bolts including scrapping of rust and painting on pumps, 20 ltrs expansion tank complete all as specified and as directed. |
| 2 | Supply & Fix in replacement of single phase computerized alternating twin pump controller suitable to operate 2 Nos 2 HP booster pumps alternatively with following features,a) short circuit protection,b) overloadprotection,c) low voltage protection,d) dry run protection,e) 1 inch graphic display showing voltage, current, Auto/manual mode, pressure switch high/lowf) Both pumps bypass toggle switches,g) Inbuilt timers for ON time/OFF time.complete all as specified and interconnected with fioat switch/pressure switch, making electrical connections and testing at site including taking down unserivecable panel |
| 3 | Supply & Fix in replacement of float switch with counter weight to interconnectwith booster pump for safety of dry run complete all as specified and as directed. |
| 4 | Supply & Fix in replacement of pressure switch (regulation range 2-14 bar, diff range 0.7 to 4 bar) including taking down unserivceable complete all as specified and as directed. |
| 5 | Supply & Fix in replacementliquid filled pressure gauge (0-10 bar/0-150 Psi ) including taking downunserviceable complete all as specified and as directed. |
| 6 | Material and labour for 3 phase centrifugal monoblockpumpsetfoundationalignmentupto 10 HP capacityincluding disconnectionof pumpset electrical connections/suction and delivery pipes,removing of pumpsetfrom foundations, removing of rusted/broken foundation bolts by dismantlingof PCC/RCC and making good of foundation by observing with water level indicator/ mercury level indicator maintaining asthetic view and re-fixing pumpset with new foundation bolts on re- alignedfoundationand testing at site complete all as specified and as directed. |
| 7 | All as per item No. 6 here-in-before but of capacity single phase, 1 HP pumpsets. |
| 8 | Supply & Fix in replacement of powder coated metal safety guards of min size 300mmx200mmx220mm complete all as specified and as directed. |
| 9 | Supply & Fix in replacement of dry run protection relay (current based) with adjustable current setting, single phase, 240V compatible with MU2P single phase DOL starter and testing with pump dry run complete all as specified and as directed by Engr-in-charge.Make : L&T (i-AD) or equivalent insiemens/C&SNote : The relay should trip the supply min 3 times of dry run condition inpresence of JE/AGE, otherwsie contractor has to ensure its functionality without extra cost. |
| 10 | Supply & Fix in replacement of single phase preventer & dry run protection relay (current based) with adjustable current setting, three phase, 4l5V compatible with MK1/MU/MUGthree phase starters and testing with pump dry run complete all as specified and as directed.Make : L&T (i-ADS) or equivalent insiemens/C&SNote : The relay should trip the supply min 3 times of dry run condition inpresence of JE/AGE, otherwsie contractor has to ensure its functionality without extra cost. |
| 11 | Supply & Fix in replacement of single phase i-protector wire harness of min 1.5 Mtr length complete all as specified and as directed. |
| 12 | Supply & Fix in replacement of three phase i-protector wire harness of min 1.5 Mtr length complete all as specified and as directed. |
| 13 | Supply & Fix in replacement orange/black coloured iron fan covers suitable to 3 phase pumps of capacity upto 10 HP capacity complete all as specified and as directed. |
| 14 | All as per item No.13 here-in-before but of capacity single phase, 1 HP pumpsets. |
| 15 | Supply & Fix in replacement of external PVC fan frame of 3 phase pumpsets capacity upto 10 HP complete all as specified and as directed. |
| 16 | All as per item No.15 here-in-beforebut of capacity single phase, 1 HP pumpsets. |
| 17 | Material and labour for scraping the old paint by using wire brush and emery paper and preparation of the surface for painting the following pump set\"s /control panel /suction and delivery pipe of the pump house with one coat of primer and two coat of synthetic enamel paintall as specified and directed at site of the following items of Water supply installations:- |
| 18 | 10 HP Pumpsets |
| 19 | 7.5HP Pumpsets |
| 20 | 5HP Pumpsets |
| 21 | 01 HP pump |
| 22 | Material and labourfor cleaning of treated water tanks of 50,000 ltrs capacity by dewatering the sump, removal of sand/muddy water/ sewage sludge by using sludge pumps, removal of left out sludge from the floor, transport & deposit of sludge at designatedplace/ dump yard including making necessary breakage of slab/roof of sump to movement manpower/tools/ventilationto caryyout job work and making good complete all as specified and as directed by Engr-in-charge. Location : Golf pump houseNote : Contractor has to make sure availability necessary ventilation before commencementwork, contractor has to carryout work safety procedures. contractor is solely responsible for any damage to government property and working manpower. |
| 23 | Supply & Fix in replacementof 3 phase, 75 kW/l00 HP VFD drive, C Choke, Inbuilt PLC, LCD Display unit,150 Amps including removal of unserviceable soft starter module and re-fixing VFD drive. The VFD drive specifications as, capacity : 75 KW/100 HP suitable for 100 HP pumpset,Application : Variable speed and smooth start.Protection : Overload, Under voltage and all other protections for 100 HP pumpset.Rated Voltage / Frequency : 3-phase AC 380-480 V ( -15%to+10%), 50 / 60 Hz . Make : DELTA (C-2000 series) VFD750C43A-00or equivalent in ABB/Siemens |
| 24 | Material and labourfor removing of all electrical connections of 75 KW soft starter panel control wiring,bus bars, electrical connections of contactors/ pumpsets/ incoming cables and re-wiring of starter panel as compatible for VFD drive controller including following,a) Fixing of 200A MCCB as panel incomer,b) VFD drive LCD display unit to be fixed on starter panel front side for easy operation,c) Fixing of 2 Nos push buttons as \"speed increase\" and \"speed decrease\" including interconnection with VFD drive, and necessary control wiring, cable connections requiredinside starter panel including programming of VFD drive as required at site.Note : The contractor has to intimate two different speeds to pump to sumps at 127 Mtr head, 146 Mtr head @ 270 Cum/hr discharge. The quotedrate is inclusive of necessary training to operators for atleast one month. |
| 25 | Supply & Fix in replacement MCB, 230V, 10kA \"C\" curve, DP 6-32A in the panels complete all as specified and directed.Make : L&T/C&S/Havells or equivalent |
| 26 | Supply & Fix in replacementof old u/s DOL starter (Direct on line)1 phase 230 Volts 50 Hz relay range 06 to 10 Amps including taking down old materialcomplete all as specifiedand as directed.TYPE: MU2PMake : L&T/C&S/AE |
| 27 | Supply & Fix in replacement of old u/s DOL starter (Direct on line) 3 phase 415 Volts 50 Hz relay range 6-I0A/9-14Aincluding taking down old materialcomplete all as specified and as directedby Engineer-in-Charge. TYPE: MK1Make : L&T/C&S/AE |
| 28 | Supply & Fix in replacementFASD (Fully Automatic Star Delta starter) 3 phase 415 Volts 50 Hz relay range 13-22A including taking down old materialcomplete all as specified and as directed.TYPE: MKlMake : L&T/C&S/AE |
| 29 | Supply & Fix in replacement of old u/s Rigid non-metallic PVC conduit of dia 25mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and and as directed. |
| 30 | Supply & Fixin replacement of old u/s PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 3 core x 16 sqmm including taking down old unserviceable materialcomplete all as specified and as directed.Make : Finolex/Hazells/Polycab or equivalent |
| 31 | All as per item No.26 here-in-beforebut of 3 core x 6 sqmm. |
| 32 | All as per item No.26 here-in-beforebut 3 core x 2.5 sqmm. |
| 33 | Supply & Fix in replacement of 12.5 KVAR box type MPP capacitor, 440V connected to motor starter panels complete all as specified and as directed. |
| 34 | All as per item No.29 here-in-before but of capacity 20 KVAR. |
| 35 | Supply & Fix in repair copper conductor cable of 1100V grade, PVC insulated, round sheathed (flexible) un-armouredindustrial cable of size 50 Sqmm x 3 core with proper saddles & lugs complete all as specified and as directed.Make : Polycab/Gloster/KEI or equivalent. |
| 36 | Supply & Fix in replacement of SS cable tray of size 75mm width, 25mm height including necessary bends, covers complete all as specified and as directed. |
| 37 | Supply & Fix as in repairs LT Panel indoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartmentwith 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over a coat of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys,all MCCBs must be have thermal magnetic release, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables,affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and as directed including the following fixtures amd fitments mentionedbelow. |
| 38 | Busbars:-Four pole 400 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming:-(i) MCCB 250 Amp, 4 Pole - 02 No, (ii) Change over switch 250 Amp 4 Pole -01 No (iii) CT\"s 250/5 -03 No.,(iv) Digital type multifunction meter .(vi) Phase Indicating lamps -03(vii) Control fuses / MCB -03 Nos |
| 39 | Outgoing:-Separate cubical chamber with a cable alley not less than 300 mm width for installation/ connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. |
| 40 | (i) MCCB, 4 pole 160 A, 36 KA-01 No(ii) MCCB,4 pole 100 A, 16 KA -04 Nos (iv) MCBTPN 40 A- 02Nos(iv)MCB, SPN 40 A-03 Nos Make of MCCB: L&T / Seimens / Schneider / ABB |
| 41 | Note:- (i) A clear space of 200 mm shall be kept from floor level for switchgear compartment.(ii) Air ventilation breathers with exhaust fan plastic body 100mm sweep to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. (iii) Each compartment shall be numbered / lettered as approved by GE.(iv) LT panel shall be fixed in existing location and the disturbed surrounding surfaces shall be made good as per exising specifications. The cost of making good shall be deemed included in unit quoted rate.(v) Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the bulk order. |
| 42 | All as per serial item No. 33 here-in-before butwith the following fittings & fixures :- |
| 43 | BusbarsTPN-400 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming (i) MCCB 250 A, 4 Pole, 36KA -01 No(ii) CT\"s 250/5 -03 No. with 01 selector switch -01 No. (iii) Ammeter 0 - 250 A digital type with selector switch -01 No. (iv) Voltmeter 0 - 500 V digital type with selector switch -01 No.(v) Phase Indicating lamps -03 No. (vi) Control fuses/MCB 32 Amp SP -03 No. |
| 44 | Outgoing:-(i) MCCB, 4 pole 125 A, 36 KA- 01Nos(i) MCCB, 4 pole 125 A, 16 KA- 02 Nos(ii) MCCB, 4 pole 100 A, 16 KA- 02 Nos(iii) MCB SPN 32 A - 02 NosMake of MCCB: L&T / Seimens / Schneider / ABB |
| 45 | Material & Labour for painting old surfaces of Feeder Pillar boxes / LT panels of any sizes at site with two coats of synthetic enamel paintDANCOT/Asian make shade / tint as approved including preparation of surfaces, cleaning rusted portion complete all as specified and as directed. |
| 46 | Material & Labour for cleaning of inside and out side (not less than 10 mtr surroundings ) of the substation including sweeping, removal of grass, dust, cobwebs, waste materials, vegetation and debris, cleaning of floors, walls,cable trenches and approach path etc. Collecting disposing all debris and rubbish from the sub station permises complete all as specified and as directed. Note : Alltools, consumables, and safety equipment required for proper completion of work are included in the quoted rate. |
| 47 | Material & Labour for cleaning of the surrondings of the outdoor feeder pillar panel (not less than 10 mtr surroundings ) including sweeping, removal of grass, dust, cobwebs, waste materials, vegetation and debris,cable trenches and approch path etc. Collecting disposing all debris and rubbish from the sitecomplete all as specified and as directed. Note : Alltools, consumables, and safety equipment required for proper completion of work are included in the quoted rate. |
| 48 | Material & Labour repair to LT Panel board indoor / outdoor type of any capacity having 1 No Incomer &out going MCCB\"s up to 6 Nos (Max) by carrying out the following works:-(i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by using blower.(ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing.(iii) Replacement of Indicator lamps, Volt meter, Amps meter, VSS, ASS as required as per existing.(iv) Replacement of Incoming / out going switches as per existing make & model.(v)Replacement of control wiring with suitable size as per existing copper wire(vi) Making the locking arrangement functional including welding if required (vii) Replacement of MV danger board(viii) Making proper connections for out going / incoming cable by providing suitable thimble as required.Note: MCCB\"s, Indicator lamps, Volt meter, Amps meter, Voltage Selector Switch / Ampere Selector Switch shall be measured and paid separatly as \"Supply only\" against respective item of this Schedule. |
| 49 | Supply and fix in repairfollowing fixtures / fittings for replacement in LT Panel boards:- |
| 50 | MCCB, 36 KA, 4 pole, 400A |
| 51 | MCCB, 36 KA, 4 pole, 250A |
| 52 | MCCB, 36 KA, 4 pole, 200A |
| 53 | MCCB, 36 KA, 4 pole, 160A |
| 54 | MCCB, 16 KA, 3 pole, 125A |
| 55 | MCCB, 16 KA, 3 pole, 100A |
| 56 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complete all as specified and as directed. |
| 57 | Material & Labour for removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 58 | Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 59 | Material & Labour for spreading riddle earth for cushioning andcovering of the UG cable in two layers, first laylers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ ducts including consolidation of each layers complete all as specified and as directed. |
| 60 | Material and labour well burnt old size sub Class ‘B’ bricks, laid flat,in trenches for cable protection complete all as specified and as directed. |
| 61 | Material & Labour for cutting the existing road/ hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/ pipe, width 0.5 Mtr and depth 0.7 Mtr all as directed and making good the road/ hard using pre mix bituminous as required at site to match with the existing surface all as specified and as directed. NOTE: Before using the hand drilling/ breaker machine diamond cutter will be used as specified andas directed. |
| 62 | Supply and layingXLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable cross sectional area 70 Sqmm, 3.5 corein trenches or fixed to wall/ passing through pipe/ pole and testing compete all as specified and as directed. Note : (i) Excavation & earth work, Brick protection and sand cushioning shall be measured and paid for separately. |
| 63 | All as per description of item No.46.00 here-in-before but Cross sectional area 95 sq mm, 3.5 core |
| 64 | M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thickpacked layer of charcoal dust and common salt filled in alternate layers and electrode connections by usingGalvanised earth strip 25x4mmconnected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wireand GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover,test point etc. |
| 65 | Material & Labour for earthing continuity conductor or main earthing lead fixed to wall on batten on recess or chases or buried in ground or dawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 x 4 mm Aluminium strip forconnection. |
| 66 | Supply, repair and replacement ofpower contactor ML-4 TP,Fr 3 size Amps rating 100/70,415V of coil voltage 220 V with aux contact 2 No + 2 NCincluding taking down the old unserviceabel contractor part No SS 90910 complete all as specified and as directed.Make : L&T or equivalent |
| 67 | Taking down carefully Aluminum/ copper point wiring complete for light, fan, 5 A socket, 15 Amps socket, 2 way points and bell point etc in any type of wiring with boards, holders and any type of electrical fittings etc complete & making good to disturbed area, complete all as specified and as directed. |
| 68 | Material and labour for point wiring with FRLS PVC insulated unsheathed electric cable confirming to IS:694,1100 V grade AC, single core having multistranded copper conductor of size 1.5 sqmm nominal cross sectional area for phase & neutralincluding non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed/ Open wiring system as per site requirement & 1.5 sqmm PVC insulated copper conductor connected to common earth dolly including provision of suitable size of modular metal surface box fixing in wall with and including white colour cover plates for mounting modular type switches, sockets, fan regulators, bell pushes etc. Note :- (i) Necessary PVC rigid junction boxes for identifying junction as required on site, for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.(a) one light point controled by one 1 way switch, all as specified and as directed. |
| 69 | (b) One fan/Exhaust pointpoint controlled by one switch |
| 70 | Supply & Fix modular switch6 Amp, 230 volts AC one way, complete all as specified and as directed. Make -Indoasian/Havells/Legrand/Schneider/Gold Medal |
| 71 | Supply & Fix modular fan regulator electronic step typecomplete all as specified and as directed. Make -Indoasian/Havells/Legrand/Schneider/Gold Medal |
| 72 | Supply & Fix of ceiling rose 3 terminal suitable for 230 volts AC supply,complete all as specified and as directed. |
| 73 | Supply & Fix in repair Modular white cover plate with frame& plastic boxes 8 module 230 Volts ACcomplete all as specified and as directed. |
| 74 | Supply & Fix in repair Modular white cover plate with frame & plastic boxes 6 module 230 Volts ACcomplete all as specified and as directed. |
| 75 | Supply & Fix in repair Modular white cover plate with frame & plastic boxes 4 module 230 Volts ACcomplete all as specified and as directed. |
| 76 | Supply & Fix in repair Modular white cover plate with frame & plastic boxes 3 module 230 Volts AC complete all as specified and as directed. |
| 77 | Taking down old US submain wiring of aluminium conductor cable of 2.5 ,4,6,of any size sq.mm, complete all as specified and as directed. |
| 78 | Material and labour for2.5 Sq mm Sub main wiring with 2 runs of single core PVC insulated unsheathed multistranded copper conductor cables FRLS of drawn through and including PVC conduitof suitable sizewith all necessary fittings and provn of one run of 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductorcable as earth continuity conductor and connecting to common earth dolly all as specified and as directed. |
| 79 | Material and labour for4.0 Sq mm Sub main wiring with 2 runs of single core PVC insulated unsheathed multistranded copper conductor cables FRLS of drawn through and including PVC condiut of suitable sizewith all necessary fittings and provn of one run of 4.0sqmm single core PVC insulated unsheathed multistranded copper conductorcable as earth continuity conductor and connecting to common earth dolly all as specified and directed. |
| 80 | Material and labour for6.0 Sq mm sub main wiring with 2 runs of single core PVC insulated unsheathed multistranded copper conductor cables FRLS of drawn through and including PVC conduitof suitable sizewith all necessary fittings and provn of one run of 6.0sqmm single core PVC insulated unsheathed multistranded copper conductorcable as earth continuity conductor and connecting to common earth dolly all as specified and as directed. |
| 81 | Attending day to day complaints which including interruption/failure of power supply/voltage variation/tripping of circuit breaker including MCBs/MCCBs/ACBs, etc. including replacement of unserviceable switch, sockets , fan regulator, fan condenser, light fittings etc. Removing burned cable from DBs and repair the same with new MCBs.NOTE :-- (i) New parts shall be measured and paid separatelyunder relevant item(s) of this schedule as \"Supply Only\". (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the fittings and fixtures in serviceable conditions and its fixing in position and testing shall be arranged by the contractor at his own cost.(iii) If contractorfailto attend the complaint within 2 hrs, a penality of Rs.200.00 per hr will be imposed on him upto 12 hrs then after a penality of Rs.500.00 per hr will be imposed. In this matter GE\"s decision is final. |
| 82 | Supply only modular switch6 Amp, 230 volts AC one way, complete all as specified and as directed. |
| 83 | Supply only modular bell push AC, 230 Volts 6 Amp complete all as specified and as directed. |
| 84 | Supply onlymodular Modular switch 2 way 6A1 module, 230 Volts 6 Amp complete all as specified and as directed. |
| 85 | Supply only modular fan regulator electronic step type complete as specified and as directed. |
| 86 | Supply only of ceiling rose 3 terminal suitable for 230 volts AC supply, complete all as specified and as directed. |
| 87 | Supply only of call bell, ding dong, 230 volts AC supply all as specified and as directed. |
| 88 | Supply onlySwitch piano type single pole, one way 15 Amps 230 Volts AC circuit complete all as specified and as directed. |
| 89 | Supply only stepped type electronic fanregulator flush type on the existing phenolic laminated sheet etc. all as specified and as directed. |
| 90 | Material and labour for disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans etc. of any description, any sweep and from any position / locations for repairs / servicingdismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, painting of fan with leaf, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessaryadjustment and proper alignment of blades, painting ,hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid separately as “Supply only\" under appropriate item of Sch ‘A’. Fixing charges for new items are deemed to be excluded under this item. (ii)Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep. (iii) Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’above item. |
| 91 | Supply only ball bearing No 6200 to 6203, all as specified and as directed. |
| 92 | Supply only capacitor of capacity 2.5 mfd(PVC body), all as specified and as directed. |
| 93 | Supply only capacitor of capacity 3.15 mfd(PVC body), all as specified and as directed. |
| 94 | Supply and fix in repairs twin core flexible cords with multistranded copper conductor of size 1.50 sqmm,1100 volts grade from ceiling rose to connector block of ceiling fans/ exhaust fans all as specified and as directed. |
| 95 | Supply and fixing of300mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and as directed. |
| 96 | Supply and fixing of 900mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and as directed. |
| 97 | Supply and fixing of 1200mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and as directed. |
| 98 | Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-chargefor the following fans:- |
| 99 | Rewinding of motor of ceiling fans 1200/1400 mmsweep. |
| 100 | Rewinding of motor of exhaust fans 225/250 mmsweep. |
| 101 | Rewinding of motor of exhaust fans 300/400 mmsweep. |
| 102 | Rewinding of motor of exhaust fans 450 mmsweep. |
| 103 | Supply and fix MCB SP 240 Volt of capacity 16 to 32 Amps ‘C’ series, complete all as specified and as directed. |
| 104 | Supply and fix in replacement of old unservisablemild steel frame with four legs suitable for 300 mm to 450 mm exhaust fan smoke grey colour painted including nuts and bolts suitable for Khaitan /Polar/Bajaj/Orient/CG/Havellscomplete all as specified and as directed. |
| 105 | Supply and fix in replacementfan blade of mild steel duly paintedsplit pin suitable for 300 mm to 450 mm exhaust fan of smoke grey colourincluding nut and bolt suitable for Havells,CG completeall as specified and as directed. |
| 106 | Supply and fix in replacementfan blade of mild steel duly painted split pin suitable for 1200 mm celing fan of existing colour including nut and bolt suitable for Havells,CG completeall as specified and as directed. |
| 107 | Supply and fix in replacement offan motor suitable for exhaust fan of Size 450 mm sweep,100-120 Watt,230 V,50 Hz,minimum 2100 RPM to ISI markedcomplete all as specified and as directed. |
| 108 | Supply and fix in replacement offan motor suitable for exhaust fan of Size 300 mm sweep,50-60 Watt,230 V,50 Hz,minimum 1360 RPM to ISI marked complete all as specified and as directed. |
| 109 | Supply and fix in replacement of fan motor suitable for ceiling fan of Size 1200 mm sweep,100 Watt,230 V,50 Hz,minimum 1360 RPM, ISI markedcomplete all as specified and as directed. |