| 1 | Taking down/dismantling solar water heater system carefully of capacity 100 Ltr including PUF insulated tank, solar flat plate collector 100 Ltr, solar evacuated tube collector, EPDM gasket, dummy flange, UNSV/rusted nut bolt/screw etc, vaccumn glass tube, neoprene gasket, plastic tube holder, rubber ring, UNSV heating element, 3 core PVC insulated and PVC unsheathed copper conductor and repair to repairable item with cleaning of tube (inner and outer portion with descaling solution) replacement to UNSV parts as mentioned above, alongwith replacement to fatal/rusted/UNSV gasket/nut bolt etc all as specified and directed by Engr-in-Charge.\"Note:- (a) Minor items and its repair work as such nut bolt/screw, welding, cleaning, setting, adjusting, testing/commissioning etc shall be deemed in the quoted rate and nothing shall be extra payment to contractor/vendor(b) Transportation from site to workshop and workshop to site shall be deemed in the quoted rate.(c) All major replacement item shall be measured and paid separately as supply only and fixing, installation alongwith testing etc shall be deemed in the quoted rate. |
| 2 | Supply only PUF insulated tank capacity 100 Ltr suitable for FPC system alongwith provision of heating element and thermostate for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 3 | Supply only MS powder coated stand for 100ltr tank of FPC (flat plate collector system) ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge. |
| 4 | Supply only solar flat plate collector of 100 LPD capacity complete set required for FPC system as per IS and marked with ISI for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 5 | Supply only collector to tank inter connecting synthetic rubber hose suitable for FPC system of 100 LPD for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 6 | Supply only hose clip suitable for FPC system of 100 LPD for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 7 | Supply only EPDM gasket with centre hole suitable for FPC system of 100 LPD ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 8 | Supply only dummy gasket suitable for FPC system of 100 LPD ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 9 | Supply only dummy flange suitable for FPC system of 100 LPD ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 10 | Supply only M6x25MM SS-304 Nut bolt with flat and spring washer suitable for FPC system above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 11 | Supply only repair 13x8 PAN head screw suitable for FPC system for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 12 | Supply only PUF insulated tank capacity 100 Ltr suitable for ETC system longwith provision of heating element and thermostate for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 13 | Supply only MS powder coated stand for 100ltr tank of ETC (evacuated tube collector system) ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge. |
| 14 | Supply only solar evaucated tube collector of 100 LPD capacity complete set required for ETC system as per IS and marked with ISI for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 15 | Supply only 58mm(D) x 1800mm(L) vacuum glass tube suitable for ETC system of 100 LPD ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 16 | Supply only neoprene gasket (58ID) suitable for ETC system of 100 LPDISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 17 | Supply only tube holder plastic suitable for ETC system for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 18 | Supply only black rubber ring suitable for ETC system for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 19 | Supply only electrical back-up heater with inbuilt thermostat 2 KW suitable for FPC/ETC system PUF insulated tank for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Supreme/V-Guard/Tata or equivalent approved by AGE(I) |
| 20 | Supply only 20 mm diaheat proof ( pre insulated ) composit pipe for hot water distribution linewith all fittings fixed to wall or ceiling/floor including taking down old unserviceable GI pipe ISI marked for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 21 | All as per item No here in before but 25 mm bore complete for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 22 | Supply only gun-metal, globe or gate valves, with iron wheel head, screwed both ends of iron pipe of size 20 mm dia for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 23 | Supply only gun-metal, globe or gate valves, with iron wheel head, screwed both ends of iron pipe of size 25 mm dia for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 24 | M & L for cleaning and descaling water circulation system of rotational moulded polyethyline water storage tank upto 500 ltrs capacity (cylindrical vertical with closed top) hoisted with descaling chemical solution and re-fixing in position complete all as specified and directed by Engr-in-Charge |
| 25 | Supply only ball brass valves, high pressure, with polyethylene float and flynut complete screwed for iron pipe or brass ferrule and fixed of size 20mm for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 26 | Supply only ball brass valves, high pressure, with polthene float and flynut complete screwed for iron pipe or brass ferrule and fixed of size 25mm for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 27 | Supply only NRV stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed on walls of size 25mm for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 28 | Supply only NRV stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed on walls of size 20mm for above Ser item No 1 complete all as specified and as directed by Engr-in-Charge.Make:- Jindal/Tata/Astral |
| 29 | S&F in repair for framed work such as tank caging grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed by Engr-n-Charge. |
| 30 | M&L in repair welded steel wire not less than 3mm dia fabric supplied and fixed complete weight per sq mtr not exceeding 4 kg to wood or steel members incl necessary welding complete all as specified and as directed by Engr-in-Charge |
| 31 | S&F in repair 100mm long butt hings medium weight cold rolled mild steel and including necessary welding as directed by Engr-in-Charge. |
| 32 | M&L in repair for preparation of steel surfaces of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified and directed by Engr-in-Charge. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge. |
| 34 | S&F in repair 3 core flexible cord PVC insulated and PVC sheathed copper conductor size of 2.5 sq mm complete all as specfied and as directed by Engr-in-Charge.Make of cable:- Finolex/Polycab/V-Guard |
| 35 | S&F in repair submain wiring concealed with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 2.5 Sq mmdrawn into non metallic medium duty rigid concealedPVCcondute not less than 25mm size ISI markedwith allfittings / accessories and 2.5 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wirewith color coding ie Phase-Red, Neutral-Black, Earth-Green duly complied as per IE rule force in vogue complete all as specified and as directed by Engr-in-Charge.Make of cable:- Finolex/Polycab/V-Guard/HavellsMake of PVC conduit:- PressFit/AKG/Jindal/Austro |
| 36 | S&F in repair Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 4 way 240 Volts AC complete all as specified and as directed by Engr-in-Charge.Make:- Schneider Electric/L&K/Legrand/Siemens |
| 37 | S&F in repairMCB SPN 40 Amps 240 volt,50 hz,10 KA breaking capacity \"C\" curved type complete all as specified and as directed by Engr-in-Charge.Make:- Schneider Electric/L&K/Legrand/Siemens |
| 38 | M&L for testing, troubleshooting, and diagnose projector hardware parts failures and to rectify including replacement of faulty components of Panasonic projector held at avadh auditorium picture hall and conduct testing on completion and troubleshooting functions with the assistance of information in the form of written or verbal descriptions/diagrams, perform data input of required material, perform work in a darkroom environment, distinguishing different color hues and shades of black and white for projector color adjustment, perform quality inspections on all completed processes, read and interpret schematic diagrams and technical manuals, research and order parts required for individual repairs, provide feedback to supervisors of any observed trends or unusual failure conditions, miscellaneous daily tasks including shipping support and clean-up activities complete all as specified and as directed by Engr-in-Charge. |