| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified. and directed by Engr-in-Charge. |
| 2 | M & L Cement concrete 1:4:8 type D2 (40 mm graded crushed stone aggregate ) in foundations, filling and mass concretecomplete all as specified. and directed by Engr-in-Charge. |
| 3 | Use and waste form work to sides of concrete foundations footings base of columns, plinth beams, raft and raft beams, sides and soffits of foundation as specified omplete all as specified. and directed by Engr-in-Charge. |
| 4 | S & F TMT bars 10 mm dia and above,cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge. |
| 5 | S & F TMT bars of 6 and incl 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips all as specified and directed complete all as specified. and directed by Engr-in-Charge. |
| 6 | M&L RCC Nominal mix, 1:2:4, type B1 using 20mm graded agg as foundations, including rafts, fottings, foundation beams; plinth beams; bases for columns, etc,; basement slabs, under reamed piles and mass concrete complete all as specified. and directed by Engr-in-Charge. |
| 7 | S&F for Steel work in tubular trusses including special shaped washer etc. complete usingERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified. and directed by Engr-in-Charge. |
| 8 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified. and directed by Engr-in-Charge. |
| 9 | S&F ,12mm dia Mild steel rag or lewis bolts, screwed one end,with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30cm long complete all as specified. and directed by Engr-in-Charge. |
| 10 | M&L painting onsteel surface over 10 cm width or girth including preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. and directed by Engr-in-Charge. |
| 11 | S&FPre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified. and directed by Engr-in-Charge. |
| 12 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. and directed by Engr-in-Charge. |
| 13 | Returning, filling in excavated soil including spreading, leveling watering and well remming layers not exceeding 25 cm thick complete all as specified. and directed by Engr-in-Charge. |
| 14 | Removing exavated material (Soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 15.m above tghe starting point,complete all as specified. and directed by Engr-in-Charge. |
| 15 | M&L for 100mm thick Cement concrete type B- 2,1:2:4 (40mm graded aggregate) as in sub base of flooring complete all as specified. and directed by Engr-in-Charge. |
| 16 | M&L for 75mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) complete all as specified. and directed by Engr-in-Charge. |
| 17 | M&L forPrecast cement concrete block in PCC 1:3:6 type C1 (using 20 mm graded aggregate) masonry with solid block exc. 10 cm in width and setting in CM (1:4) complete all as specified |
| 18 | M&L 15mm thick cement plaster in CM (1:4) on fair faces of brick walls surface and concete surface, finished even and smooth w/o using extra cement and using water proofing compound(external surface) complete all as specified. and directed by Engr-in-Charge. |
| 19 | M&L preparing new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer all as specified and directed by Engr-in-charge. |
| 20 | Taking down carefully aluminium point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. |
| 21 | Supply and fixing in repair 1100 Volts grade heavy duty cable PVC insulated aluminimum conductor of size 16 Sq mm twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, flat or circular all as specified and directed by Engineer-in-Charge . |
| 22 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Chargefor following :-(a) One light point/one fan point controlled by one switch |
| 23 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Chargefor following :-(b) One 3 pin 5 amps socket outlet independent with cables 1.5 sqmm size |
| 24 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Chargefor following :-(c) One 3 pin 5 Amp socket outlet on same board. |
| 25 | All same as per item No 23 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable. |
| 26 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. |
| 27 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge. |
| 28 | S&fSwitch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge . |
| 29 | S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr in Charge . |
| 30 | M&Lfor ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge. |
| 31 | S & FLED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engr in Charge. |
| 32 | Supply and Fixing indoor LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge. |
| 33 | S&Fbasic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long,with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXACP7IN1W010 or equivalent in Philips/Crompton) |
| 34 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long,with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXAXPNIN1W020 or equivalent in Philips/Crompton) |
| 35 | S&Fin repairsheet metal powder coated versatile Double door SPN distribution board,8 way suitable for MCB\"s fitted with copper bus bar rated 200amps, neutrallink , earth bar and din rail suitable for use on 240 Volt, 50Hz with all accessories complete all as per specified and as directed by Engr-in-Charge.. |
| 36 | M&L in repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of \"C\" series in distribution boardswith all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 37 | S&F in repair to MCB SP 6-32 Amp with 10KA breaking capacity of \"C\" series in distribution boardswith all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 38 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per specified and as directed by Engr-in-Charge. |
| 39 | M & L in repair for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt,connected to MS galvanized earh stripof size 25 x 4 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. |