| Sl. No. | Item Description |
| 1 | S&Fin replacement of power command Controller for automatic shifting supply for capacity of 40 to 125 KVA as per existing DG set fixed at site complete all as specified and directed by Engineer-in-Charge. |
| 2 | S&Fin replacement of power command controller for automatic shifting supply for capacity of 160 to 250 KVA complete all as specified and directed by Engineer-in-Charge. |
| 3 | Dismantling /opening of upper portion of diesel engine 30 KVA to 75 KVA (Make:greaves/ Kirloskar,/Cumiuns/ water cooled ,turbo charged 1500 RPM ,vertical type for Top over hauling ,repair/servicing of engine includingtaking out rediator/fuel pump,water pump ,turbo charger etc.for the following repairs/overhauling :- (a)Dismantlling/opening of complete cylinder head assembly rocker arms assembly piston head assembly sleeves by by removing nuts & bolts for repairs complete. Note 2:-Repair and Transportation charge for carrying out pair and after repair carrying back to Power House shall be deemed to be included in this rates.(b)Servicing& Washing of complete engine parts with Kerosene oil. (c) Re-assembling of engine after replacement of UNSV/defective parts with new parts as listed in given below and testing of engineas per company recommendation after reassembling all parts as direted to the satifaction of the Engr-in-Charge. |
| 4 | Piston Assembly With Pistan ring Set |
| 5 | Cylinder Liner |
| 6 | Liner O Ring |
| 7 | Ring Set |
| 8 | Joint Kit |
| 9 | Head Gasket |
| 10 | Hose Pipe |
| 11 | Valve Inset Seat |
| 12 | Valve Guide |
| 13 | Valve Seal |
| 14 | Connecting Rod With Bearing |
| 15 | FIP Element Complete |
| 16 | Lub Oil Pump Assembly |
| 17 | Conrod with small end bush and locating pin |
| 18 | Dismantling /opening of upper portion of diesel engine 100KVA to 160 KVA (Make:greaves/ Kirloskar,/Cumiuns/ water cooled ,turbo charged 1500 RPM ,vertical type for Top over hauling ,repair/servicing of engine includingtaking out rediator/fuel pump,water pump ,turbo charger etc.for the following repairs/overhauling :- (a)Dismantlling/opening of complete cylinder head assembly rocker arms assembly piston head assembly sleeves by by removing nuts & bolts for repairs complete. Note 2:-Repair and Transportation charge for carrying out pair and after repair carrying back to Power House shall be deemed to be included in this rates.(b)Servicing& Washing of complete engine parts with Kerosene oil. (c) Re-assembling of engine after replacement of UNSV/defective parts with new parts as listed in given below and testing of engineas per company recommendation after reassembling all parts as direted to the satifaction of the Engr-in-Charge. |
| 19 | Piston Assembly With Pistan ring Set |
| 20 | Cylinder Liner |
| 21 | Liner O Ring |
| 22 | Ring Set |
| 23 | Joint Kit |
| 24 | Head Gasket |
| 25 | Hose Pipe |
| 26 | Valve Inset Seat |
| 27 | Valve Guide |
| 28 | Valve Seal |
| 29 | Connecting Rod With Bearing |
| 30 | FIP Element Complete |
| 31 | Lub Oil Pump Assembly |
| 32 | Conrod with small end bush and locating pin |
| 33 | Dismantling /opening of upper portion of diesel engine 200KVA to 320 KVA (Make:greaves/ Kirloskar,/Cumiuns/ water cooled ,turbo charged 1500 RPM ,vertical type for Top over hauling ,repair/servicing of engine includingtaking out rediator/fuel pump,water pump ,turbo charger etc.for the following repairs/overhauling :- (a)Dismantlling/opening of complete cylinder head assembly rocker arms assembly piston head assembly sleeves by by removing nuts & bolts for repairs complete. Note 2:-Repair and Transportation charge for carrying out pair and after repair carrying back to Power House shall be deemed to be included in this rates.(b)Servicing& Washing of complete engine parts with Kerosene oil. (c) Re-assembling of engine after replacement of UNSV/defective parts with new parts as listed in given below and testing of engineas per company recommendation after reassembling all parts as direted to the satifaction of the Engr-in-Charge. |
| 34 | Piston Assembly With Pistan ring Set |
| 35 | Cylinder Liner |
| 36 | Liner O Ring |
| 37 | Ring Set |
| 38 | Joint Kit |
| 39 | Head Gasket |
| 40 | Hose Pipe |
| 41 | Valve Inset Seat |
| 42 | Valve Guide |
| 43 | Valve Seal |
| 44 | Connecting Rod With Bearing |
| 45 | FIP Element Complete |
| 46 | Lub Oil Pump Assembly |
| 47 | Conrod with small end bush and locating pin |
| 48 | M&L in replacementof fuel pump complete with all accessories of 30 KVA to 160 KVA DG Set ,complete all as specified and directed by Engr-in-charge. |
| 49 | M&L in replacementof fuel pump complete with all accessories of 200 KVA to 320 KVA DG Set ,complete all as specified and directed by Engr-in-charge. |
| 50 | M&L for repair /overhaulingand calibration of injectors assembly complete by replacing of burn out partsuitable for 30to 160 KVA DG SET ,complete all as specifiedand directed by Engr-in-charge. |
| 51 | M&L for repair /overhaulingand calibration of injectors assembly complete by replacing of burn out partsuitable for 200 to 320 KVA DG SET ,complete all as specifiedand directed by Engr-in-charge. |
| 52 | S&Fin replacement Self Starternew one 24V/12V DCSuitable for 31.5 to 160 KVA DG Set as per existing model and type Complete all as specified and directed. . |
| 53 | S&Fin replacement Self Starternew one 24V DCSuitable for200 KVA/250KVA DG Setas per existing model and type Complete all as specified and directed. |
| 54 | S&Fin replacement,calibration and testing of turbo charger including replacement of turbo charger kit splite seal ,cup screw ring retainer and burn out nuts bollt etc for 30KVA to 160 KVA DG set incl connecting pipe and accessories as per existing model and type Complete all as specified and directed. |
| 55 | S&Fin replacement,calibration and testing of turbo charger including replacement of turbo charger kit splite seal ,cup screw ring retainer and burn out nuts bollt etc for 200 KVA to 320 KVA DG set incl connecting pipe and accessories as per existing model and type Complete all as specified and directed.. |
| 56 | S&Fin replacement, AVR suitable for 30to 160 KVA as per existing model and type Complete all as specified and directed. |
| 57 | S&Fin replacement, AVR suitable for 200to 320 KVAas per existing model and type Complete all as specified and directed. |
| 58 | Taking out UNSV and Supply and replacement of battery charger of 0-24 volts DC for charging of lead acid battery of 2-12 V of any amp rating battary including taking down complete as per exsting make and type all as specifeid and directed by engr-in-charge. |
| 59 | Taking out UNSV and Supply and replacement of battery charger of 0-12 volts DC for charging of lead acid battery of 2-12 V of any amp rating battary including taking down complete as per exsting make and type all as specifeid and directed by engr-in-charge. |
| 60 | Supply and installing as in replacement of 12 volt 80 AH lead acid wet maintenance free battery including initial charging with necessary material connecting with battery lead of DG Set at site and setting aside unserviceable material for reuseor carry storecomplete including taking down. |
| 61 | Taking out UNSV and M&L for asbestos rope of suitable size andsuperier qualityfor heat insulation including rapping arround the exhaust pipe and winding with wire mess and plastering with plaster of peris /white cement for smooth finishing all as specified and directed by engr-in-charge. |
| 62 | Supply only 15W-40 Engine oil Make- HP/Servo/MAK |
| 63 | S&Freplacement heavy duty battery lead for 180 AH , 12 V battery copper conductor PVC insulated multistranded 1.25 mtr long (Two Nos) duly fixed and lugs complete all as directed |
| 64 | S&Fin replacement heavy duty battery terminals brass forged with nuts and bolts complete all as directed |
| 65 | Servicingof self starter from DG sets of 62.5KVA to 320KVA and replacement of the U/Sitems and reassembling & refixing to exsting DG sets including necessary servicing made 100 % servicibility and testing complete all as directed.Note :-Spare shall be measure and paid sapartely.on relevent items only |
| 66 | Taking out UNSV andSupply & Fixing Solenoid Switch 01 No. |
| 67 | Taking out UNSV andSupply & FixingArmature 01 No. |
| 68 | Taking out UNSV and Supply& FixingField coil copper 01 Set. |
| 69 | Taking out UNSV and Supply & FixingCarbon Brush 01 Set. |
| 70 | Taking out UNSV and Supply & FixingBearing |
| 71 | Taking out UNSV and Supply & FixingPinion 01 Nos |
| 72 | S&Fin replacement radiator made up of copper inside tank and fins as per fanufacture\"s design of Kirloskar/Greaves suitable for 30 to 160KVA DG Set including taking out old and unserviceable radiator for demolition or credit complete all as directed by Engineer -in-charge |
| 73 | S&Fin replacement of radiator made up of copper inside tank and fins as per fanufacture\"s design of Kirloskar/Greaves suitable for 200 KVA to 320KVA DG Set including taking out old and unserviceable radiator for demolition or credit complete all as directed by Engineer -in-charge |
| 74 | Dismantling, opening and cleaning of complete radiator assembly of DG Set 30KVA to 100 KVA, Make : Kirloskar/Cummins/ Crompton Greaves and checking of water leakage, including upper and bottom tank cleaning of slots including welding/brazing where requiredand making 100 % leak proof and washingwith chemically anti corrosion /water sooution by using jet pumping set and well as cleaning manually by usingsteel wire brushes and removing all rust silt /corrosive material and making good smooth functioning and replacement of radiator hose pipe set,and upper &bottom tank gasket set,all rusted nut ,bolt ,washer ,radiator caps etc complete all as specified and directed by Engineer-in-Charge. |
| 75 | Dismantling, opening and cleaning of complete radiator assembly of DG Set 125-320 KVA, Make : Kirloskar/Cummins/ Crompton Greaves and checking of water leakage, including upper and bottom tank cleaning of slots including welding/brazing where requiredand making 100 % leak proof and washingwith chemically anti corrosion /water sooution by using jet pumping set and well as cleaning manually by usingsteel wire brushes and removing all rust silt /corrosive material and making good smooth functioning and replacement of radiator hose pipe set,and upper &bottom tank gasket set,all rusted nut ,bolt ,washer ,radiator caps etc complete all as specified and directed by Engineer-in-Charge. |
| 76 | Servicing of DG set capacity 160 to 320 KVA installed at 23 Wing AF including carrying out maintenance and check alongwithfollowing repairs (a)Drain out the lubricatingoil from sump and refilling after proper cleaning (b)Replace Engine Oil filter cartridge .(c)Renew fuel filter cartridge (d)Check tightness of all nuts and bolts (e)Check adjustment of V belt for driving engine water pump and alternator.(g)Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge.(h)Testing of DG set after servicing as per Engr –in Charge.(j)Cleaning of air cleaner filter after period of hrs run as specified by manufactures in manual Note:-(i)Any minor parts such as screws, washers , split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted.(ii) The Job shall be carried out after two hundred hrs run /as when required directed by engr-in-charge of DG Setand shall be measured and paid separatly,no of times carried out during entire period of contract (iii) Drain out the fuel from fuel tank and refilling after proper cleaning with the help of high pressure pump complete all as specified. |
| 77 | S&Fin replacement oil pipe of DG Set 160-320 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 78 | S&Fin replacementlub oil filter of DG Set 160-320 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 79 | S&Fin replacementAirfilter of DG Set 160-320 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 80 | S&Fin replacementfuel diesel filter of DG Set 160-320 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 81 | Servicing of DG set capacity 10 to 125 KVA installed at 23 Wing AF including carrying out maintenance and check alongwithfollowing repairs (a)Drain out the lubricatingoil from sump and refilling after proper cleaning (b)Replace Engine Oil filter cartridge .(c)Renew fuel filter cartridge (d)Check tightness of all nuts and bolts (e)Check adjustment of V belt for driving engine water pump and alternator.(g)Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge.(h)Testing of DG set after servicing as per Engr –in Charge.(j)Cleaning of air cleaner filter after period of hrs run as specified by manufactures in manual Note:-(i)Any minor parts such as screws, washers , split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted.(ii) The Job shall be carried out after two hundred hrs run /as when required directed by engr-in-charge of DG Setand shall be measured and paid separatly,no of times carried out during entire period of contract (iii) Drain out the fuel from fuel tank and refilling after proper cleaning with the help of high pressure pump complete all as specified. |
| 82 | S&Fin replacement oil pipe of DG Set 30 to 125 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 83 | S&Fin replacement lub oil filter of DG Set 30 to 125 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 84 | Supply & Fixing in replacement Airfilter of DG Set 30 to 125KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 85 | S&Fin replacementfuel diesel filter of DG Set 30 to 125 KVA, complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves. |
| 86 | M&Lin replacement alternator from DG sets of 30 KVA to 320KVA DG Setcap after disconnection of cable /earth lead and decompute from engine ,transportation to the civil workshop After Repair Alternaterrefixing the existing DG set connecting with engine ,connecting with cable earth lead and complete testing on load all as specified and directed by engr-in-charge. |
| 87 | Rewinding ofAlternator Complete Includingandsupply and replacementof copper Wire including suitable winding material rewinding the stator windingwith existing size,guage &weight of super enamelled copper wire of approved make including replacement of all insulating material varneshing with approved grade and quality of insulating varnish during up,and heating the stator windingin the heat chamber ,insulating , assembling the alternatorComplete.all as specified and directed by engr-in-charge. |
| 88 | Supply only distilled water for lead acid battery all as directed . |
| 89 | Supply only dioute Sulphuric acid for lead Acid Battery. |
| 90 | Supply only coolentfor DG sets.as per approved quality and directed by Engr-in -Charge. |
| 91 | SupplyHand RotaryBarrel Pumpto power house for filling of fuel complete with 2mtr 25mm flexible PVC Pipe all as specified. |
| 92 | M& L for repair/re-winding of old excitation coil complete with necessary connection after repairing including opening ,disconnecting of electrical connection ,opening canopy as per requirment .complete all as specified and as directed. |
| 93 | Supply and replacement of speedo meter /Hr meter alongwith connecting cord as per exsting make incl all Connected acessories complete all as specified and directed . |
| 94 | Taking out carban brush holder of following DG set ,supply and fix new carban brush holder as per existing size and make in item |
| 95 | 160to 320 KVA DG set |
| 96 | 75 to125 KVA DG set |
| 97 | 30 to 70 KVA DG set |
| 98 | Taking out UNSV andS&F MS Pipe of Size 80 mm Diafor DG Set Silencer Including Welding And Painting complete all as specified |
| 99 | Taking out UNSV andS&F MS Pipe of Size 100 mm Diafor DG Set Silencer Including Welding And Painting complete all as specified |
| 100 | Taking out UNSV andS&Ffan belt for30 to 320 KVAof DG set as per existing type/Model complete all as specified and directed. |
| 101 | Taking out UNSV andS&Ffan beltfor alternator ofDG Set of any capacity and make as per existing type/Model complete all as specified and directed.. |
| 102 | S&Ffly wheel gear ring for75 KVA to 320 KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 103 | Supply and installing as in replacement of 12 volt 150 AH lead acid wet maintenance free battery including initial charging with necessary material connecting with battery lead of DG Set at site and setting aside unserviceable material for reuseor carry storecomplete including taking down. |
| 104 | S&Fwater pump assy suitable for 30KVA to 125 KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 105 | S&Fwater pump assy suitable for 160 KVA to 320 KVADG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 106 | S&FFan drive assy suitable for 30to 125 KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceableas per existing type/Model complete all as specified and directed. . |
| 107 | S&FFan drive assy suitable for 160 to 320KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 108 | S&F thermostat for 30to 125 KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 109 | S&F thermostat for 160 to 320KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 110 | S&Fresidential silencer suitable for 30to 125 KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 111 | S&Fresidential silencer suitable for 160 to 320 KVA DG Set of Make: Greeves/Kirloskar including taking out the old Unserviceable as per existing type/Model complete all as specified and directed.. |
| 112 | Taking out UNSV and Supply & Fixing Rediator hose Pipe( for water pipe ) for DG Set of Capacity 31.5KVA to 160KVA complete all as specifed . |
| 113 | Taking out UNSV andSupply & Fixing Rediator hose Pipe( for water pipe ) for DG Set of Capacity 200KVA to 320KVA complete all as specifed. |
| 114 | Supply only 15W-40 Engine oil Make- HP/Servo/MAK |
| 115 | Taking out UNSV andSupply & Fixing Rubber Spider Coupling suitable for 30 to 125 KVA DG Set as per existing type/Model complete all as specified and directed. |
| 116 | Taking out UNSV andSupply & Fixing Rubber Spider Coupling suitable for 160 to 320KVA DG Set as per existing type/Model complete all as specified and directed. |
| 117 | Supply and filling Diesel Exhaust Fluid complete all as specified and directed. |
| 118 | Supply and installing as in replacement of 12 volt 180 AH lead acid wet maintenance free battery including initial charging with necessary material connecting with battery lead of DG Set at site and setting aside unserviceable material for reuseor carry storecomplete including taking down. |
| 119 | Suppy and fixing in repair solenoid switch 12 Volt make Greaves suitale for DG Set upto 125 KVA of any make complete all as specified and directed by the Engineer-in-Charge |
| 120 | Suppy and fixing in repair solenoid switch 24 Volt make Greaves suitale for DG Set upto 320 KVA of any make complete all as specified and directed by the Engineer-in-Charge |
| 121 | Material and labour for making 100% serviceable to the AMF PANEL suitable for 30 KVA to 320 KVAby tracing out defects and replacing unserviceable parts including control wiring complete all as specified and directed. minor parts such as nuts, bolts, washers, thimbles, control wiring etc shall be deemed to be included in the quoted rate. including taking out the worn out material i.e, contactorMCCBs MCB if any r Sizeas per existing type/Model complete all as specified and directed. |
| 122 | Taking out UNSV and Supply & Fixing Selector switch 2 way 2 pole with off (6Amps) Make : Slazer or equivalent |
| 123 | Taking out UNSV andSupply & Fixing Selector switch 2 way 3 pole with off (6Amps) Make : Slazer |
| 124 | Taking out UNSV andSupply & Fixing Voltage monitoring switchmake : Slazer |
| 125 | Taking out UNSV andSupply & Fixing Three phase Over current & earth fault relay Make : L&T MC31ANX2200 |
| 126 | Taking out UNSV andSupply & Fixing Multifunction meter LED Accuracy class 1 flush mounting 96x96 mm Make : L&T Model No WDM303FDWA |
| 127 | Taking out UNSV/Repair andSupply & Fixing Current Transformer (100/5A) 5VA CL 1 Ring type (resin cast) Make AE |
| 128 | Taking out UNSV/RepairSupply & Fixing MVR (Main Voltage Relay) Over /under voltage relay voltage range 350V AC & high voltage range 460V AC Make : PIC |
| 129 | Supply & Fixing AVR (Alternator Voltage Relay) Over /under voltage relay voltage range 350V AC & high voltage range 460V AC Make : PIC |
| 130 | Taking out UNSV/RepairSupply & Fixing HRC fuse base and fuse holder complete 6 to 32 Amps Make : L&T |
| 131 | Taking out UNSV/RepairSupply & Fixing Power Contactor 4 pole 50 amps with auxillary contactMakeL&T MCX 11or equivalent in BCH/ABB |
| 132 | Taking out UNSV/RepairSupply & Fixing Power Contactor 4 pole 100 amps with auxillary contactMakeL&T MCX 22or equivalent in BCH/ABB |
| 133 | Taking out UNSV/RepairSupply & Fixing Power Contactor 4 pole 160 amps with auxillary contactMakeL&T MCX 32or equivalent in BCH/ABB |
| 134 | Taking out UNSV/RepairSupply & Fixing Power Contactor 4 pole 200amps with auxillary contactMakeL&T MCX 32or equivalent in BCH/ABB |
| 135 | Supply & Fixing Controller Control Module Panel for Diesel Generator DSE7320 with Manual /AutoElectronicsSuitable for 40 to 250 KVA DG Set |
| 136 | Taking out UNSV/RepairSupply & FixingContactor Exceed Contactors 4 pole Rating AC1 200 Amp With AC Coilas per existing size/model all as specified and directed. |
| 137 | Taking out UNSV/RepairSupplyFixing Lubricater InterOil Cooler For 31.5 KVA to 125 KVA DG Set |
| 138 | Taking out UNSV/RepairSupplyFixing Lubricater InterOil Cooler For 160 KVA to 320 KVA DG Set |
| 139 | Lifting & Shifting of DG Set up to 320 KVAone place to other placeincludingopening of Electricconnections Completewithout any damege with transportation and lifttingbyCrain and Reinstalling all as specified & directed. |
| 140 | Taking out and S&FCross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paintall as specified. |
| 141 | M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for plinth Protectionof DG Sets incl fair finishing the exposed surfaces even and smooth without using extra cement includingnecessary form work complete all as specified & directed. |
| 142 | S&Fin replacement of DG Control Panel (Suitable for Make:Greaves,2020 yrs Model) Srl No.E-1326061604867, A-PEAG0261 complete all accessories includingharnesing with DGand connected with existing AMF Panelfor ON/OFF,automatic ON/OFFfor capacity of 250 KVA as per existing DG set fixed at site complete all as specified and directed by Engineer-in-Charge. |
| 143 | S&Fin replacement of DG Control Panel (Suitable for Greaves,2013 yrs Model) Srl No.E-F63208/0800271, A-FS35108153748 complete all accessories includingharnesing with Dg and connected with existing AMF Panelfor ON/OFF,automatic ON/OFFfor capacity of 160 KVA as per existing DG set fixed at site complete all as specified and directed by Engineer-in-Charge. |
| 144 | Material and labour for earth continuity conductor or main earthing lead using 25 x 4 mm galvanised steel strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation, etc. as required including porcelain insulator saddle at the spacing nort exceeding 400mm including taking down old strip complete all as specified and directed by Engineer-in-Charge. |
| 145 | Earth continuity conductor of main earthing lead copper strip 20 x 3.15mm with porcelain insulator saddles not exceeding 400 mm spacing for roof conductors and down conductors above ground and fixing screws to wall on batten or recess or chases or buried in ground or drawn in conduit/Pipe/duct or fixed to poles or any other indicated. |
| 146 | Servicing of DG set/Transformer Trolley 160 to 320 KVAincluding carrying out maintenance and check alongwithfollowing repairs (a) Removethe 4 Wheel and servicingand apply lubricant complete all as specified (b) Replace all bearing and connected items .(c) Welding of guard Post as per trolly requirement. (d) Check tightness of all nuts and bolts (e)Check adjustment oftrolley.(g)Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge.Note:-(i)Any minor parts such as screws, washers , split pin , circlip,bearing,lubricant etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. |
| 147 | M&L and fixing inreplacement Tyre and Tube as per the existing trolly\"s tyre size/Model complete with all acccessories all as directed by Engr in charge. |
| 148 | S&F in replacement of on load change over315 Amp 4 pole complete withwith Sheet metal encloser incl operating handle and dismantling/connection ofexisting cables complete as specified and directed by Engineer-in-Charge. |
| 149 | S&Fin replacement ofMCCB 350Amps 4 pole 36 KAwith adjustablethermal and fixed magnetic setting, complete all as specified and directed. |
| 150 | S&Fin replacement of MCCB 250Amps 4 pole 35 KA with Sheet metal encloser withadjustablethermal and fixed magnetic setting, complete all as specified and directed. |
| 151 | S&Fin replacement ofMCCB 160Amps 4 pole 25 KA adjustablethermal and fixed magnetic setting, complete all as specified and directed. |
| 152 | Material and labour for trolley preparing old painted surface of trolley by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray paintingof trolley as per existing colour of trolley incl door hinges welding and locking knob as per the existing type complete all as specified and directed. |
| 153 | Suply and fixing of AMF panel for 160KVA DG Set , install, test and commisioning of new AMF Panel suitable for 3 phase, 415V, 50Hz, 160 KVA DG set, free standing, floor mounted, factory made, indoor type, made out of 2mm thick CRCA sheet totally enclosed, weather, dust and vermin proof, with front opening, 440 volts 3 phase 4 wire 50 hz having aluminium bus bar of suitable capacity for three phases and neutral duly powder coated with coloured heat shrinkable PVC sleeves, multifunctional digital controler relay for AFM operation and display of electrical parameters, manual/auto start/Stop facility, two Nos electrically operated modular contactor 4 pole of suitable capacity for DG set and main supply (auto shifting of electrical load is required), 315 Amps MCCB FP -01 No for load, and provision of Overload protection relay, Phase sequance and Single phase prevention, High voltage and under voltage protection arrangements for Contactors complete all as specified, with on/off controller indicator, Phase Indicators, running hour meter, battery charge level indicator, engine start push button, engine stop push button and fault accept / reset push buttons, selector switches,including battery charger comprising transformer, rectifier, resistance, DC volt meter DC Amp meter and charge rate selector switch, all accessories prewired with suitable size copper conductor cable or strip all as required or as recommended by manufacturer and making wiring between DG set to AMF panel complete all as specified and as directed. |
| 154 | Suply and fixing of AMF panel for 62.5KVA DG Set, install, test and commisioning of new AMF Panel suitable for 3 phase, 415V, 50Hz, 62.5 KVA DG set, free standing, floor mounted, factory made, indoor type, made out of 2mm thick CRCA sheet totally enclosed, weather, dust and vermin proof, with front opening, 440 volts 3 phase 4 wire 50 hz having aluminium bus bar of suitable capacity for three phases and neutral duly powder coated with coloured heat shrinkable PVC sleeves, multifunctional digital controler relay for AFM operation and display of electrical parameters, manual/auto start/Stop facility, two Nos electrically operated modular contactor 4 pole of suitable capacity for DG set and main supply (auto shifting of electrical load is required), 160 Amps MCCB FP -01 No for load, and provision of Overload protection relay, Phase sequance and Single phase prevention, High voltage and under voltage protection arrangements for Contactors complete all as specified, with on/off controller indicator, Phase Indicators, running hour meter, battery charge level indicator, engine start push button, engine stop push button and fault accept / reset push buttons, selector switches,including battery charger comprising transformer, rectifier, resistance, DC volt meter DC Amp meter and charge rate selector switch, all accessories prewired with suitable size copper conductor cable or strip all as required or as recommended by manufacturer and making wiring between DG set to AMF panel complete all as specified and as directed. |
| 155 | Supply, Installation, Testing and Comissioning LED Polycarbonate Guidance Signage Board (IP-65 protection) complying with ICAO standards for shoulders of Runway / Taxi Track Links withsupporting structure described as under of theSize 2.20m x 0.70m.(a) SHEET & FRAME : The Sheet and Frame of the Signage Boards shall fabricated out of anodised aluminium profile structure with 2mm thick aluminium sheet and 4mm thick long life imported non-specular surface polycarbonate sheet. The symbols of signage shall be made of self adhesive film applied on face of polycarbonate sheet. The size and shape of Signs / Numbers / Indications and Letters etc. shall be as directed at site. The frame shall be mounted on 40mm dia aluminium tubing of length as per site requirement and as directed at site. The Signage Board shall be illuminated with linear LEDs with ICs and other accessories required, suitable convertor to operate on 2.8 Amps to 6.6 Amps AC constant current as incoming supply including supply and installation of suitable capacity / wattage electronic convertor, Isolation Transformer (IT), MS boxes and other accessories complete as required at site and as directed.(b) FIXING ARRANGEMENT : The legs of the Signage Board shall be mounted on the base frame with breakable coupling and secondary leads. The legs shall embedded in pedestal made of PCC type B-2 1:2:4 (using 40mm graded crushed stone aggregate) finished with 10mm thick cement plaster in CM 1:4. The pedestal shall extend to atleast 1.0 metres all around the signage board with depth not less than 15cms all as directed at site. The earthwork in excavation required for Pedestal including returning filling in and removal of surplus spoil to a distance not exceeding 50 metres shall be done by the Contractor all as directed at site and nothing extra from the department shall be admissible on this account.Makes : VIBGYOR INDUSTRIES / SINOR / ELECTRO SYSTEM / NASU / POSH DECOR / VARDHMAN / AMA / YPR |
| 156 | Supply and laying secondary cable of size 2 x 4 Sqmm copper conductor PCP insulated PE 1.1 KV grade flexible cable complete all as specified and as directed.Make : ALOKE / RR KABEL / NEXANS / DALTONS / POLYCAB |
| 157 | Two Pin 4.0 Sqmm Secondry Plug Assembly for Signage boards complete all as specified and directed. |
| 158 | Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge. |
| 159 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 160 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil |
| 161 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 162 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 51 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, \"O\" Ring etc, for protection of cablecomplete all as specified and as directed |
| 163 | S & Fin replacement straight through joint heat shinkablesuitable for3 1/2 core 1100 volts XLPE lT UGcable of size 50 Sq mm to 70 Sq mm complete all as specified and directed. |
| 164 | SCHEDULE \"A\" PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch \"A\" Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail