| 1 | CHAPTER - IArboriculture |
| 2 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 3 | Rough dressing the trenched ground including breaking clods. |
| 4 | Fine dressing of the ground. |
| 5 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 6 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 7 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 8 | Supplyand stacking Screened through sieve of I.S. designation 16 mm at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment): |
| 9 | Screened through sieve of I.S designation 16 mm |
| 10 | Supplying & Stacking of Selection No.1 doob grass turf at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. |
| 11 | Grassing with selection No. 1 Doob grass including watering andmaintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, ifneeded (the grass and good earth shall be paid for separately).In rows 5 cm apart in both directions. |
| 12 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 13 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water).Hedge Plnt / Ground Cover. |
| 14 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 15 | Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. |
| 16 | Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge. |
| 17 | Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge. |
| 18 | Providing and stacking of plant Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 19 | Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 20 | Providing and displaying of Seaforthia Palm plant, having ht. 1.20 cm to 1.50 cm with 8-10 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 21 | Providing and Displaying Adenium Obesum grafted well developed with fresh & healthy 30 to 60 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge. |
| 22 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 23 | Providing and stacking of Hibiscus variegated of height 60-75 cm. with 8-10 branches and healthy variegated foliage in cement pots of size 35 cm as per direction of the officer-in-charge. |
| 24 | Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50 m : Common burnt clay F.P.S (non modular ) bricks of Class designation 7.5 |
| 25 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. Mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.Group C. |
| 26 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required: |
| 27 | 2 x 1.5 sq.mm + 1 x 1.5 Sq.mm earth wire. |
| 28 | 2 x 4 sq.mm + 1 x 4 Sq.mm earth wire. |
| 29 | GM Patio 12 W garden Light. Make as approved by Engineer-in-Charge |
| 30 | Hallogen LightsMake as approved by Engineer-in-Charge |
| 31 | Providingand fixing sprinkler irrigation unit(metllic / copper alloy) confirming to IS 12232in GI Pipe .Best available as approved by Engineer-in-Charge. |
| 32 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge: |
| 33 | All kinds of soil. |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 35 | 1:4:8 (1 cement : 4 coarse sand (zone-) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 36 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13529 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap thermal expansion, (i)Single socketed pipes. |
| 37 | 110 mm diameter |
| 38 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc.External work. |
| 39 | 15 mm dia nominal bore |
| 40 | 32 mmdia nominal |
| 41 | Providing and fixing gun metal gate valve with C.I wheel of approved qulity (screwed end) |
| 42 | 20 mm nominal bore |
| 43 | 32mm nominal bore |