| 1 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 2 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 4 | Diluting and injecting chemical emulsion for POST- ONSTRUCTIONALanti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 8 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 10 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 11 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 12 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 13 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick flat |
| 14 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) sqm |
| 15 | Distempering with 1st quality acrylic washable distemper (Ready mixed) of approved manufacturer of required shade and colour complete as per manufacturer specification. Two or more coats on old Work. |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 18 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 19 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 20 | Dismantling old plaster or skirting raking out joints and cleaning thesurfaceforplasterincludingdisposalofrubbishtothe dumping ground within 50 metres lead. |
| 21 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White each |
| 22 | Providing and fixing soil, waste and vent pipes : |
| 23 | 100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 24 | 75 mm diaSand cast iron S&S pipe as per IS: 1729 |
| 25 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :For 100 mm dia pipe |
| 26 | Providing and fixing heel rest sanitary bend |
| 27 | 100 mm diaSand cast iron S&S as per IS - 1729 |
| 28 | 75 mm diaSand cast iron S&S as per IS - 1729 |
| 29 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts andnuts complete. |
| 30 | 75x75x75 mmSand cast iron S&S as per IS - 1729 |
| 31 | 100x100x100 mm Sand cast iron S&S as per IS - 1729 |
| 32 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. |
| 33 | 15 mm dia nominal bore |
| 34 | 20 mm dia nominal bore metre |
| 35 | 25 mm dia nominal bore |
| 36 | Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)including disposal of malba. |
| 37 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 38 | Making connection of drain or sewer line with existing manholeincluding breaking into and making good the walls, floors with cementconcrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter |
| 39 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 40 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kgof approved make |
| 41 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers. |
| 42 | P/F Go-down lock approved quality (Harrison or equivalent )with all screws / welding etc complete. |
| 43 | P/F a custom buildcupboard with total overall depth of 600 mm. The main structure of cupboard,include the sides, top, bottom, shelves, and shutters, shall be fabricated using 18.00mm thick HDHMR ( one side prelaminated) board of approved brands such as Action Tesa, Green Ply or Century. The rear panel shall be made from 8.00 mm thick HDHMR ( one side prelaminated), the exterior must be coveredwith sunmica as well the sunmica shall be of approved brand only . The scope includes supplying and installing all necessary hardware fittings and fixtures such as hinges, handles, godrej multipurpose locks, stoppers, screws and otheraccessories. the entire work shall be carried out as per instruction of Engineer-in Charge, ensuring proper alignment , finishing and durability. ( Note : for the purpose ofpayment, only the Front face area of the cupboard will be measured in square meters, internal details will not be measured separately . |
| 44 | P/F costom built cupboard, The shutters are to be made from 18 mm thick HDHHMR board ( from brands like Action Tesa, Green ply, or Centuary or equivalent)and covered on both side with 1mm sunmica (from same brands or equialent) A complete wooden frame is required for the shutter made from 75mm x 40 mm second class teak wood, including any necessaryintermediate supports. The wooden frame must be polished with french spirit . The scope includesa applying and fitting all required hardware and fixtures (Godrej) 25 mm curvo wardrobe Multipurpose lock). All work must be completed according to the instructions of The Engineer-in Charge.(Note: for the purpose of payments, only the front face area of the cupboard will be measured in square meters, internal details will not be measured separatey) |