| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for pipes, manholes, etc notand getting out in soft/loose soil complete as specified and as directed. |
| 2 | Excavation over areas not exc1.5 m in deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Excavation over areas exc 1.5 m butnot exc 3 m in deep and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in each layer in any type of soil complete all as specified and directed. |
| 5 | Removing excavated materials soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in any type of soil all as specified and directed. |
| 6 | Demolition and breaking up 200 mm dia/bore drain pipes (Salt glazed ware, AC or Reinforced concrete) setin cement mortar/concrete and removing rubbish off the premises complete all as specified and as directed. |
| 7 | Material and labour for PCC 1:3:6 type, C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete as specified and directed. |
| 8 | Materials and Labour for plain cement concrete (1:4:8) type D-2,using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 9 | Materials and Labour for plain cement concrete (1:2:4) type B-1,using 20mm graded stone aggregate as in surface channel and drain complete all as specified and as directed. |
| 10 | Materials and Labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. all as specified and as directed. |
| 11 | Materials and Labour for Sand filling as in back filling or in foundationincluding watering and consolidation complete all as specified and as directed. |
| 12 | Supply and fixing Modular Septic Tank of Capacity 13500 Ltrs (50-70 Users) (plastic septic tank) with inlet/outlet sizes of 160mm, 2 domed ends coupled type includng all accessoried and lowering into position and fixed to inlet and outlet pipes complete all as per manufacturer instructions and directed by Engineer-in-Charge. Make:- Supreme/ Sintex Plastics/ Aqua tech. |
| 13 | Supply and fixing Modular Septic Tank of Capacity 21500 Ltrs (90-100 Users) (plastic septic tank) with inlet/outlet sizes of 160mm, stand alone type includng all accessoried and lowering into position and fixed to inlet and outlet pipes complete all as per manufacturer instructions and directed by Engineer-in-Charge. Make:- Supreme/ Sintex Plastics/ Aqua tech. |
| 14 | Materials and labour for brick work with sub class \"B\" burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 15 | Materials and labour for brick work with sub class \"B\" burnt clay bricks straight or curved on plan to any radius in one brick thick honey comb walls built in cement mortar 1:4 complete all as specified and as directed. |
| 16 | Materials and labour for broken brick bats to fill in soakage well complete all as specified and as directed. |
| 17 | Materials and Labour for formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam; and similar work; vertical or to batterfor rough finished flat surfaces of concrete complete all as specified and directed. |
| 18 | Materials and Labour for formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similer works,for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm,complete all as specified and directed |
| 19 | Material and labour for formwork to faces of wall, retaining wall, parapet etc. for rough finished surface complete all as specified and as directed. |
| 20 | Materials and Labour for reinforced cement concrete M-25 (Design Mix)e as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc; basement slabs under reamed pillars and mass concrete complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) |
| 21 | Materials and Labour for reinforced cement concrete M-25 (Design Mix)as in slabs and shelves supported on walls, beams and columns in floors, roofs and landings etc, any thickness complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) |
| 22 | Materials and Labour for reinforced cement concrete M-25 (Design Mix)as in walls, parapets etc complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) |
| 23 | Materials and Labour for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 24 | Materials and Labour for TMT bars 6-8mm dia, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 25 | Supply, laying and testing of 200 mm inner dia double wall corrugated HDPE (DWCPE) pipes of class SN-8, ISI marked pipes with all fittings and jointing materials, laid in trenches and joined for sewage line complete all as specified and directed |
| 26 | Material and labour for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in bed for drain pipes including packing underand haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete as specified and as directed. |
| 27 | Supply and fixing PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 28 | Supply and fixing PVC (SWR)junction single, (Single T) equal or unequal, 110mm bore, complete all as specified and directed. |
| 29 | Supply and fixing PVC (SWR) vent cowl 110mm bore, complete all as specified and directed. |
| 30 | Supplyand fixing factory made SFRC manhole cover with frame conforming to IS 12592:2002, HD 20 grade, of size 750mm circular surrounded with steel strip 70x1.5mm, reinforced as per relevant IS and laid over manhole complete all as specified & directed. |