| 1 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 3.5 X 50 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 2 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 3.5 X 35 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 3 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 4 X 25 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 4 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 4 X 16 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 5 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 4 X 10 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 6 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 2 X 10 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the open air along with 8 swg GI wire or as suitable for supporting the cable,etc. completeas required.Upto 35 sq. mm |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 9 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE aluminium conductor power cable of 1.1 KV grade, of size upto 35 sq. mm (clamped with 1mm thick saddle) etc. on wall/pole surface, as required. |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 11 | Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 12 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore |
| 13 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METALpipe as required.Upto 35 sq. mm |
| 15 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm |
| 17 | Supplying, installation, Testing & Commissioning of Flood Light, powdercoated pressure die cast aluminum body with built in or separate driveras per the requirement with Driver efficiency >85%, Input voltage: Inputvoltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMCas per CISPR -15 , lenses for beam angle 30 deg-120deg as per theapplication and the project requirement deg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolationIES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (Asper ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified rating and Fixtureshall be of relevant BIS standard complete in all respect i/c connectionswith 1.5 sq mm FRLS, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test reportfrom NABL lab for all testing required for LED fixtures as per BIS shallbe submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above90°C).100 watt |
| 18 | Supplying and fixing of outdoor type loop in loop out cable junction box fabricated from PVC/1.6 mm MS sheet enclosed weather proof, dust proof, water proof and locking arrangement internally embedded gasket with bottom cable entry plate through cable glands having seperate holes for incoming and outgoing cables and with wires fixed in it having clamps for fitting on steel structure or wall with followings in it. i) HD Connector for 10 to 16 sqmm -1 Set. ii)6-32 amp SP \"C\" curve 10 KA MCB-1 No. iii) fixing Clamps with nuts,bots,etc. -2 Nos. |
| 19 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sinkof aluminum housing such that LED junction temperature shall not rise above 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm)18- 22 watt |
| 20 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 21 | 3 x 1.5 sq. mm |
| 22 | 3 x 2.5 sq. mm |
| 23 | Erection of existing dismantled RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 8.0 Meter and upto 11.0 Meter |
| 24 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 25 | Supply of Exhaust fan alongwith louvers with sweep size of 250 mm, RPM 1350 and with air delivery capacity of 800 CMHconfirming to IS and IEC code as approved by the Engineer in charge. |
| 26 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. |
| 29 | Single pole |
| 30 | Double pole |
| 31 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etcincluding drilling of holes for light and painting with primer and finished paint as required . |
| 32 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.250 A,36KA,FPMCCB |
| 33 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \"C\" curve, TPMCB, in sheetsteel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 34 | Numbering of ceiling fan/ exhaust fan/ fluorescent/LED fittings as required. |
| 35 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required including crediting the same. |
| 36 | Supply and fixing of 300 to 315 A, 415 V operational voltage, 50 Hz , 4 Way, weatherproof, outdoor, floor mounting type Busbar Chamber and the same will be installed in ground with necessary CC foundation and angle stand and suitable for connection of 3 phase,4 Core Aluminium Armoured Cablesas required along withsupply and installation of 4 pole MCCB, 125A, 36kA Ics=100% Icu and Operational Voltage 690V- 1 no,on DIN rails inside the busbar chamber having removable gland plate with knock out provision and Liberal space between cable / busbar and live parts, fabricated using sheet steel (CRCA) and epoxy powder coated to give superior & lasting finish, manufacturedby CPRI approved manufacturer. |
| 37 | Supply and fixing of 63 A, 415 V operational voltage, 50 Hz , 4 Way, weatherproof, outdoor,wall mounting type Busbar Chamber and the same will be installed inwith necessary angle frame and suitable for connection of 3 phase,4 Core Aluminium Armoured Cablesas requiredwith knock out provision and Liberal space between cable / busbar and live parts, fabricated using sheet steel (CRCA) and epoxy powder coated to give superior & lasting finish, manufacturedby CPRI approved manufacturer. |