| 1 | O&M Materials for lines and Sub-Stations |
| 2 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-17 of overall length 8.50m. |
| 3 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-29 of overall length 9.00m. |
| 4 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-31 of overall length 9.00m |
| 5 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-33 of overall length 9.00m |
| 6 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-35 of overall length 9.50m |
| 7 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-37 of overall length 9.50m |
| 8 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-39 of overall length 9.50m |
| 9 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-45 of overall length 10.00m |
| 10 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 300mmx300mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-48 of overall length 10.00m |
| 11 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 300mmx300mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-56 of overall length 11.00m |
| 12 | Galvanised Swaged Steel Poles with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top con forming to IS 2713/1980 or the latest version thereof 410 SP-58 of overall length 12.00m |
| 13 | 12 Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-61 of overall length 12.00m |
| 14 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-66 of overall length 12.00m |
| 15 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-72 of overall length 13.00m |
| 16 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-76 of overall length 14.50m |
| 17 | Galvanised Swaged Steel Pole Multi-utility Pole (as per drawing enclosed in annexure) with base plate of thickness 6mm and size of 200mmx200mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-35 (Multitutility Pole as per drawing at annexure) of overall length 9.50m |
| 18 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-58 (Multi-Utility Pole as per drawing at annexure) of overall length 12.00m |
| 19 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-66 (Flanged Type as per drawing at annexure) of overall length 12.00m |
| 20 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-76 (as per drawing at annexure) of overall length 14.50m |
| 21 | Galvanised Swaged Steel Pole with base plate of thickness 6mm and size of 400mmx400mm square welded at the bottom and with pole cap of 6mm thick to be welded at the top conforming to IS 2713/1980 or the latest version thereof 410 SP-66 (Flanged Type with single arm bracket as per drawing at annexure) of overall length 12.00m |
| 22 | GI Angle Iron 40 x 40 x 6mm |
| 23 | GI Flat Iron 40 x 6mm |
| 24 | GI Channel 75 x 40 x 6mm |
| 25 | GI Channel 100 x 50 x 6mm |
| 26 | GI Washer for 16mm dia hole |
| 27 | GI Nuts & Bolts 16 x 155mm full thread |
| 28 | GI Nuts & Bolts 16 x 75mm full thread |
| 29 | GI Nuts & Bolts 16 x 50mm full thread |
| 30 | Shackle Insulator (Pin/Strap type) 70x90mm |
| 31 | Shackle Strap for 70 x 90mm Shackle Insulator |
| 32 | Shackle Nuts & Bolts 12 x 100mm (GI) |
| 33 | Polymer Composite Silicon Coated Long Rod 11kV Pin Insulator |
| 34 | Polymer Composite Silicon Coated Long Rod 11kV Insulator 45 KN |
| 35 | Tension Clamp with hardware strain fitting 3-bolted type complete with bolts, nuts and washer (Weasel) |
| 36 | Polymer Composite Silicon Coated Long Rod 33kV Pin Insulator |
| 37 | Polymer Composite Silicon Coated Long Rod 33kV Insulator 70 KN |
| 38 | Tension Clamp with hardware strain fitting 4-bolted type complete with bolts, nuts and washer (Racoon) |
| 39 | Polymer Composite Silicon Coated Long Rod 132kV Insulator 120 KN |
| 40 | Single Tension Assembly with hardware strain fitting complete with bolts, nuts and washer and Arcing Horn suitable for Panther conductor |
| 41 | Double Tension Assembly with hardware strain fitting complete with bolts, nuts and washer and Arcing Horn suitable for Panther conductor |
| 42 | Stock Bridge type Vibration Damper |
| 43 | GI Stay Set complete 16mm rod dia with Plate 30 x 30 x 0.8cm |
| 44 | Stay Wire 7/14 SWG |
| 45 | LT Guy Insulator 90 x 65mm |
| 46 | GI Stay Set complete 19mm rod dia with Plate 30 x 30 x 0.8cm |
| 47 | Stay Wire 7/12 SWG |
| 48 | 11kV Guy Insulator 140 x 85mm |
| 49 | GI Stay Set complete 19mm rod dia with Plate 40 x 40 x 0.8cm |
| 50 | Stay Wire 7/10 SWG |
| 51 | 33kV Guy Insulator 140 x 85mm |
| 52 | Hard drawn standard aluminium conductors conforming to IS:398 (Part-I) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: AAC 7/2.91mm GNAT |
| 53 | Hard drawn standard aluminium conductors conforming to IS:398 (Part-I) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: AAC 7/3.10mm ANT |
| 54 | Hard drawn standard aluminium conductors conforming to IS:398 (Part-I) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: AAC 7/3.91mm GRASSHOPPER |
| 55 | Hard drawn standard aluminium conductors galvanised steelwire reinforced conforming to IS:398 (Part-II) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: ACSR 6/1/2.59mm WEASEL |
| 56 | Hard drawn standard aluminium conductors galvanised steelwire reinforced conforming to IS:398 (Part-II) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: ACSR 6/1/4mm RACOON |
| 57 | Hard drawn standard aluminium conductors galvanised steelwire reinforced conforming to IS:398 (Part-II) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: ACSR 7/1/4.26mm DOG |
| 58 | Hard drawn standard aluminium conductors galvanised steelwire reinforced conforming to IS:398 (Part-II) with Amendment No.1, 2 & 3 or the latest version thereof bearing ISI mark: ACSR 30/7/3.0mm PANTHER |
| 59 | GI Wire 8 SWG for earth wire/support wire |
| 60 | ACSS 30/7/290 HTLS Conductor |
| 61 | PG Clamp for GNAT conductor (2-bolted type) |
| 62 | PG Clamp for ANT conductor (2-bolted type) |
| 63 | PG Clamp for GRASSHOPPER conductor (3-bolted type) |
| 64 | PG Clamp for WEASEL conductor (3-bolted type) |
| 65 | PG Clamp for RACOON conductor (3-bolted type) |
| 66 | PG Clamp for DOG conductor (3-bolted type) |
| 67 | PG Clamp for PANTHER conductor (3-bolted type) |
| 68 | Jointing Sleeve for Weasel conductor |
| 69 | Jointing Sleeve for Racoon conductor |
| 70 | Jointing Sleeve for Dog conductor |
| 71 | Mid Span Compression Joint for Panther conductor |
| 72 | Repair Sleeve for Panther conductor |
| 73 | Copper Earth Bond for 7/3.15mm galvanised stranded steel core earth wire |
| 74 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS33kV 1C x 30 sqmm Weasel AL59 ACS Triple Extruded Covered Conductor 173 Amps |
| 75 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS33kV 1C x 52.88 sqmm Rabbit AL59 ACS Triple Extruded Covered Conductor 242 Amps |
| 76 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS33kV 1C x 78.82 sqmm Raccoon AL59 ACS Triple Extruded Covered Conductor 313 Amps |
| 77 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS 33kV 1C x 105 sqmm Dog AL59 ACS Triple Extruded Covered Conductor 365 Amps |
| 78 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS 33kV 1C x 120 sqmm Dog + AL59 ACS Triple Extruded Covered Conductor 384 Apms |
| 79 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS 33kV 1C x 158 sqmm Wolf + AL59 ACS Triple Extruded Covered Conductor 450 Amps |
| 80 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS 33kV 1C x 241 sqmm Panther + AL59 ACS Triple Extruded Covered Conductor 599 Amps |
| 81 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS 11kV 1C x 30 sqmm Weasel AL59 ACS Triple Extruded Covered Conductor 175 Amps |
| 82 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS11kV 1C x 52.88 sqmm Rabbit AL59 ACS Triple Extruded Covered Conductor 245 Amps |
| 83 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS11kV 1C x 78.82 sqmm Raccoon AL59 ACS Triple Extruded Covered Conductor 316 Amps |
| 84 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS11kV 1C x 105 sqmm Dog AL59 ACS Triple Extruded Covered Conductor 369 Amps |
| 85 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS11kV 1C x 120 sqmm Dog + AL59 ACS Triple Extruded Covered Conductor 389 Amps |
| 86 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS11kV 1C x 158 sqmm Wolf + AL59 ACS Triple Extruded Covered Conductor 455 Amps |
| 87 | Stranded Aluminium Conductor (AL59) with Aluminium coated steel reinforces, semi conducting layer, XLPE insulated and overall XLPE outer sheeth with UV resistant and anti tracking properties as per EN 50397-1, 2006 TYPE : AL59 ACS 11kV 1C x 241 sqmm Panther + AL59 ACS Triple Extruded Covered Conductor 605 Amps |
| 88 | Galvanised Steel Rod 2m long, 19mm dia connected with GI Wire complete with terminal connector |
| 89 | GI Earth Pipe 2.5m long, 40mm dia with 8mm thickness fabricated for Pole earthing complete with terminal connector |
| 90 | Bentonite Powder |
| 91 | Lightning Spike made of iron rod 10mm, 1.5m long, 1kg welded with MS Flat Iron 40x5mm, 0.5kg and 8 SWG GI Wire 2.5kg |
| 92 | Lightning Arrestor 0.280kV, 2.5kA for LT line |
| 93 | Lightning Arrestor 9kV, 5kA |
| 94 | Lightning Arrestor 9kV, 10kA Station Class-II |
| 95 | Lightning Arrestor 30kV, 10kA Class-II |
| 96 | 1.1kV Aluminium Armoured Cable 1-core, 10sq.mm |
| 97 | 1.1kV Aluminium Armoured Cable 1-core, 16sq.mm |
| 98 | 1.1kV Aluminium Armoured Cable 1-core, 35sq.mm |
| 99 | 1.1kV Aluminium Armoured Cable 1-core, 50sq.mm |
| 100 | 1.1kV Aluminium Armoured Cable 1-core, 70sq.mm |
| 101 | 1.1kV Aluminium Armoured Cable 1-core, 95sq.mm |
| 102 | 1.1kV Aluminium Armoured Cable 1-core, 120sq.mm |
| 103 | 1.1kV Aluminium Armoured Cable 1-core, 150sq.mm |
| 104 | 1.1kV Aluminium Armoured Cable 1-core, 185sq.mm |
| 105 | 1.1kV Aluminium Armoured Cable 1-core, 225sq.mm |
| 106 | 1.1kV Aluminium Armoured Cable 1-core, 300sq.mm |
| 107 | 1.1kV Aluminium Armoured Cable 1-core, 400sq.mm |
| 108 | 1.1kV Aluminium Armoured Cable 1-core, 630sq.mm |
| 109 | GI Pipe 40mm dia, 4.13m long |
| 110 | LT Cable Termination Kit 1-core for all size of cable |
| 111 | Aluminium Cable Lug long Barrel 10sq.mm |
| 112 | Aluminium Cable Lug long Barrel 16sq.mm |
| 113 | Aluminium Cable Lug long Barrel 35sq.mm |
| 114 | Aluminium Cable Lug long Barrel 50sq.mm |
| 115 | Aluminium Cable Lug long Barrel 70sq.mm |
| 116 | Aluminium Cable Lug long Barrel 95sq.mm |
| 117 | Aluminium Cable Lug long Barrel 120sq.mm |
| 118 | Aluminium Cable Lug long Barrel 150sq.mm |
| 119 | Aluminium Cable Lug long Barrel 185sq.mm |
| 120 | Aluminium Cable Lug long Barrel 240sq.mm |
| 121 | Aluminium Cable Lug long Barrel 300sq.mm |
| 122 | Aluminium Cable Lug long Barrel 400sq.mm |
| 123 | Aluminium Cable Lug long Barrel 630sq.mm |
| 124 | LT Cable Termination Kit 3½ core for all size of cable |
| 125 | T-connector for 300sq.mm cable |
| 126 | T-connector for 400sq.mm cable |
| 127 | T-connector for 630sq.mm cable |
| 128 | 1.1kV Aluminium Armoured Cable 3½ core, 10sq.mm |
| 129 | 1.1kV Aluminium Armoured Cable 3½ core, 16sq.mm |
| 130 | 1.1kV Aluminium Armoured Cable 3½ core, 35sq.mm |
| 131 | 1.1kV Aluminium Armoured Cable 3½ core, 50sq.mm |
| 132 | 1.1kV Aluminium Armoured Cable 3½ core, 70sq.mm |
| 133 | 1.1kV Aluminium Armoured Cable 3½ core, 95sq.mm |
| 134 | 1.1kV Aluminium Armoured Cable 3½ core, 120sq.mm |
| 135 | 1.1kV Aluminium Armoured Cable 3½ core, 150sq.mm |
| 136 | 1.1kV Aluminium Armoured Cable 3½ core, 185sq.mm |
| 137 | 1.1kV Aluminium Armoured Cable 3½ core, 225sq.mm |
| 138 | 1.1kV Aluminium Armoured Cable 3½ core, 300sq.mm |
| 139 | 1.1kV Aluminium Armoured Cable 3½ core, 400sq.mm |
| 140 | 1.1kV Aluminium Armoured Cable 3½ core, 630sq.mm |
| 141 | 11kV GOAB Switch 200A |
| 142 | 11kV Fuse Unit with Arcing Horn 200A |
| 143 | 1kV GOAB Switch 400A |
| 144 | 11kV Fuse Unit with Arcing Horn 400A |
| 145 | 3 phase HRC Main Switch, 250 A conforming to IEC : 60947 (Part 3) - 1999 or any ammendments up to date. |
| 146 | HRC Fuse, 250 A, conforming to IS : 13703 - 1993 or any ammendments up to date. |
| 147 | 3 phase HRC Main Switch, 400 A conforming to IEC : 60947 (Part 3) - 1999 or any ammendments up to date. |
| 148 | HRC Fuse, 400 A, conforming to IS : 13703 - 1993 or any ammendments up to date. |
| 149 | 3 phase HRC Main Switch, 630 A conforming to IEC : 60947 (Part 3) - 1999 or any ammendments up to date. |
| 150 | HRC Fuse, 630 A, conforming to IS : 13703 - 1993 or any ammendments up to date. |
| 151 | 11kV Isolator with Earthswitch |
| 152 | 11kV PT 2-core metering & protection, outdoor type with PTR: 33kV/√3/110V/√3, accuracy class core-I 0.5, core-II 3P |
| 153 | 1kV Indoor type CT |
| 154 | 1.1kV XLPE Insulated ABC 3x120sq.mm with 16sq.mm St.Light and XLPE Insulated Messenger 95sq.mm |
| 155 | 11kV XLPE Insulated ABC 3x70sq.mm + 1x55sq.mm Bare Messenger |
| 156 | 11kV XLPE Insulated ABC 3x95sq.mm + 1x70sq.mm Bare Messenger |
| 157 | 11kV XLPE Insulated ABC 3x120sq.mm + 1x95sq.mm Bare Messenger |
| 158 | 400A, 36kA Adjustable Thermal Magnetic MCCB 3-phase, 4-pole conforming to IEC: 60947 (Part 2) - 2003 or any amendments up to date. |
| 159 | 630A, 36kA Adjustable Thermal Magnetic MCCB 3-phase, 4-pole conforming to IEC: 60947 (Part 2) - 2003 or any amendments up to date. |
| 160 | 11kV XLPE Aluminium Cable 1-core, 600sq.mm |
| 161 | 11kV XLPE Aluminium Cable 1-core, 400sq.mm |
| 162 | 11kV XLPE Aluminium Cable 1-core, 240sq.mm |
| 163 | 11kV XLPE Aluminium Cable 1-core, 185sq.mm |
| 164 | 11kV XLPE Aluminium Cable 1-core, 150sq.mm |
| 165 | 11kV XLPE Aluminium Cable 1-core, 120sq.mm |
| 166 | 11kV XLPE Aluminium Cable 1-core, 100sq.mm |
| 167 | 11kV XLPE Aluminium Cable 1-core, 95sq.mm |
| 168 | 11kV XLPE Aluminium Cable 1-core, 50sq.mm |
| 169 | 11kV XLPE Aluminium Cable 3-core, 400sq.mm |
| 170 | 11kV XLPE Aluminium Cable 3-core, 240sq.mm |
| 171 | 11kV XLPE Aluminium Cable 3-core, 185sq.mm |
| 172 | 11kV XLPE Aluminium Cable 3-core, 150sq.mm |
| 173 | 11kV XLPE Aluminium Cable 3-core, 120sq.mm |
| 174 | 11kV XLPE Aluminium Cable 3-core, 95sq.mm |
| 175 | 11kV XLPE Aluminium Cable 3-core, 50sq.mm |
| 176 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 600 sq. mm |
| 177 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 400sq.mm |
| 178 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 240sq.mm |
| 179 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 185sq.mm |
| 180 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 150sq.mm |
| 181 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 120sq.mm |
| 182 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 100sq.mm |
| 183 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 95sq.mm |
| 184 | Cable Termination Kit for 1-core, 11kV XLPE Al. Cable 50sq.mm |
| 185 | Cable Termination Kit for 3-core, 11kV XLPE Al. Cable 400sq.mm |
| 186 | Cable Termination Kit for 3-core, 11kV XLPE Al. Cable 240sq.mm |
| 187 | Cable Termination Kit for 3-core, 11kV XLPE Al. Cable 185sq.mm |
| 188 | Cable Termination Kit for 3-core, 11kV XLPE Al. Cable 150sq.mm |
| 189 | Cable Termination Kit for 3-core, 11kV XLPE Al. Cable 120sq.mm |
| 190 | Cable Termination Kit for 3-core, 11kV XLPE Al. Cable 100sq.mm |
| 191 | Outdoor type oil immersed naturally cooled3-ph, 50HzAl-wound Distribution Transformer of vector group DYn-11 conforming to IS : 1180 (1964) and IS : 2026 (1962) or latest versionthereof and ISI marked of the following capacity 25kVA 11/0.415 kV. |
| 192 | Outdoor type oil immersed naturally cooled3-ph, 50HzAl-wound Distribution Transformer of vector group DYn-11 conforming to IS : 1180 (1964) and IS : 2026 (1962) or latest versionthereof and ISI marked of the following capacity 63kVA 11/0.415 kV. |
| 193 | Outdoor type oil immersed naturally cooled3-ph, 50HzAl-wound Distribution Transformer of vector group DYn-11 conforming to IS : 1180 (1964) and IS : 2026 (1962) or latest versionthereof and ISI marked of the following capacity 100kVA 11/0.415 kV. |
| 194 | Outdoor type oil immersed naturally cooled3-ph, 50HzAl-wound Distribution Transformer of vector group DYn-11 BIS Level-II conforming to IS : 1180 (1964) or latest versionthereof andthe following capacity 160 kVA 11/0.415 kV. |
| 195 | Outdoor type oil immersed naturally cooled3-ph, 50HzCu-wound Distribution Transformer of vector group DYn-11 conforming to IS : 1180 (1964) and IS : 2026 (1962) or latest versionthereof and ISI marked of the following capacity 250kVA 11/0.415 kV. |
| 196 | Outdoor type oil immersed naturally cooled3-ph, 50HzCu-wound Distribution Transformer of vector group DYn-11 BIS Level-II conforming to IS : 1180 (1964) or latest versionthereof and the following capacity 500kVA 11/0.415 kV. |
| 197 | 33kV Isolator with Earthswitch |
| 198 | 33kV Isolator without Earthswitch |
| 199 | 33kV PT 2-core metering & protection, outdoor type with PTR: 33kV/√3/110V/√3, accuracy class core-I 0.2, core-II 3P |
| 200 | 33kV outdoor type CT |
| 201 | 33kV XLPE Aluminium Cable 1-core, 400sq.mm |
| 202 | 33kV XLPE Aluminium Cable 1-core, 240sq.mm |
| 203 | 33kV XLPE Aluminium Cable 1-core, 185sq.mm |
| 204 | 33kV XLPE Aluminium Cable 1-core, 120sq.mm |
| 205 | 33kV XLPE Aluminium Cable 3-core, 400sq.mm |
| 206 | 33kV XLPE Aluminium Cable 3-core, 240sq.mm |
| 207 | 33kV XLPE Aluminium Cable 3-core, 185sq.mm |
| 208 | 33kV XLPE Aluminium Cable 3-core, 120sq.mm |
| 209 | Cable Termination Kit for 1-core, 33kV XLPE Al. Cable 400sq.mm |
| 210 | Cable Termination Kit for 1-core, 33kV XLPE Al. Cable 240sq.mm |
| 211 | Cable Termination Kit for 1-core, 33kV XLPE Al. Cable 185sq.mm |
| 212 | Cable Termination Kit for 1-core, 33kV XLPE Al. Cable 120sq.mm |
| 213 | Cable Termination Kit for 3-core, 33kV XLPE Al. Cable 400sq.mm |
| 214 | Cable Termination Kit for 3-core, 33kV XLPE Al. Cable 240sq.mm |
| 215 | Cable Termination Kit for 3-core, 33kV XLPE Al. Cable 185sq.mm |
| 216 | Cable Termination Kit for 3-core, 33kV XLPE Al. Cable 120sq.mm |
| 217 | 11 kV Indoor Switchboard Incoming Panelwith the following specifications: 12kV, 1250A, 25kA, Multi panel, shunt trip, Indoor Type, motor operated, spring closing Vacuum Circuit Breaker, CT having accuracy class of 0.2 for metering & 5P10 for protection, PS for special protection, PT having accuracy class of 0.2for metering,and PS for Special , MW meter, ammeter, voltmeter, frequency meter, power factor meter, overcurrent and earth fault relays (numerical Relay Micom P-127 or equivalent) with time delay setting facilities, trip supervising relay, master trip relay, Smart energy meter (RF/GPRS connectivity), import & export recorder, SIM card compatible, fault annunciator, digital metering, event logger, disturbance recorder, communication facilities, Surge Protection Device for AC & DC, etc. of the latest technology. |
| 218 | 33kV Control and Relay Transformer Panel complete with digital MW, KV, PF, Frequency meter, KVAR meter indicators as necessary; numerical O/C and E/F relays and transformer auxiliary protection such as (alarm and trip) buchholz relays, WTI, OTI etc.; trip circuit supervising relay, master trip relay, annunciator, remote switches, Smart energy meter (RF/GPRS connectivity) and Surge Protection Device for AC & DC. The O/C and E/F relay shall conform to IEC 60255 and IS:3231 of the latest versions. Aux supply shall be of 110V DC. |
| 219 | 110V DC Float cum Boost Battery Charger suitable for charging 100/250AH battery and supply of continuous load at 15A with DC output 15 nos. of 2P 32A MCB DC terminals. Input:415V ± 10%, 3-Ph, 50Hz, 4Wires. Output: 110V DC / 40A (BC) |
| 220 | 110V DC, 250 Ah, SMF-VRLA Battery Bank consisting of 55 nos. cell. Model: UPST-250 along with MS Steel enclosure and inter cell connection complete with accessories. |
| 221 | Numerical Distance Relay |
| 222 | Numerical Overcurrent and Earthfault Relay |