| 1 | M&L for Locating fault of LT underground cables 2/3.5/4 core of size 16-300 Sqmm laid in trenches using fault locator machine/manually and repairing the same by making LT joint ferrule etc. including necessary excavation & earth work upto 10 metre length, taking out the protection cover, sand and faulty cable and relaying the cable after necessary repair including refilling of sand and relaying of protection cover and RFR complete all as directed by Engineer-in-Charge. NOTES : (a) The quoted rate includes cost of arranging, shifting of fault locator machine including operator fee, T&P required, any number of times as and when required during the currency of contract. (b) The contractor will have to arrange the fault locating machine. In case contractor fails to diagnose/locate the fault within 04 Hrs of fault intimation, a penalty of Rs. 50/hour will be imposed/ levied.(c) LT joint will be measured and paid separately.(d) The quantity catered will be executed different times during currency of work whenever fault occurs. |
| 2 | M&L for Cable joining kit of size 6/10 Sq. mm, 4 core (straight through cold shrinkable) for 1100 V (Earthed) grade cablecomplete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified and directed. |
| 3 | M&L for Cable joining kit of size 16-35 Sq. mm, 3.5 to 4 core (straight through cold shrinkable) for 1100 V (Earthed) grade cablecomplete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified and directed. |
| 4 | M&L for Cable joining kit of size 50-95 Sq. mm, 3.5 core (straight through cold shrinkable) for 1100 V (Earthed) grade cablecomplete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified and directed. |
| 5 | M&L for Cable joining kit of size 120-185 Sq. mm, 3.5 core (straight through cold shrinkable) for 1100 V (Earthed) grade cablecomplete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified and directed. |
| 6 | M&L for Cable joining kit of size 240-400 Sq. mm, 3.5 core (straight through cold shrinkable) for 1100 V (Earthed) grade cablecomplete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified and directed. |
| 7 | M&L for surface dressing in hard / dense soilnot exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate including filling of river sand/ stone dust upto 15cm complete all as specified and directed at site. Note:- (i)Stone dust/river sand shall be measured and paid separately under relevant items of this schedule. (ii)The rate also deemed to be included for labour. |
| 8 | M&L forstone aggregate of size not exceeding 40 mm deposited spread and levelled in layers not exceeding 15 cm to a true surface of broken stones for transformer yard andpole structure area. |
| 9 | Supply spread dry river sand/stone duston top surface of the installation area at technical and domestic area all as specified and directed by Engineer-in-Charge. |
| 10 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in deep and getting outin soft/loose soilfor laying/taking out of underground cables and foundation of poles etc and getting out complete all as specified and directed by Engineer-in-charge. |
| 11 | Returning, filling in trenches (soil), including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Removing of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.Note : Item Sl No 10 to 12 considered for providning cable joint kit. |
| 13 | M & L for PCC 1:3:6 type C1, 20mm graded aggregate for coping of poles etc all as specified and as directed. |
| 14 | Supply and fix in repairs all in one Solar Street Light outdoor type with LED Street light 30 Watt, Solar panel of capacity not less than 50Wp, input Voltage 9V, IP-66 rating, cool white colour, 25 Hz, not less than 3900 lumens, CCT not less than 6000K, input current less than 2ma, efficiency not less than 90%, Battery 12 V and 18 Ah lithium ion, with 5 mtr long pole height compete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for Earthing IN REPLACEMENT with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE:- (i)Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 16 | M&L for Earthing IN REPLACEMENT with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 25mmx4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE:- (i)Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 17 | M&L for Earthing IN REPLACEMENT with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE:- (i)Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 18 | M&L for Earthing IN REPLACEMENT with copper earth plate electrode 60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip 20mmx3mm by means of bolts, nuts, check nuts and washers all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE:- (i)Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 19 | Cleaning of substations located at AF Stn Adampur once in a month as per Engineer-in-charge instructions by applying cloth for removing dirt on all the equipment’s located inside the sub stations and removing all the grass weeds/vegetation with roots or by applying spray of Herbicides outside the sub stations. Note:-(i)Each E/M Sub Station/Installation cleaning will be carried out once in a month and the same will be measured as one job during the period of contract i.e. six months.(ii) The rate for labour/herbicidesto beincluded in the quoted rate. (iii) The quoted rate shall also include the rate of materials like cotton, Broom, MAFF, Stick for mounting Broom, Phenol which are required for the cleaning of installations. |
| 20 | Supply and fix in replacement cable route indicator made out of 3 mm thick MS sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed by Engineer- in- charge. |
| 21 | S&F Automatic street light control panel 8 KW, 32 Amp, 3 phase FR grade thermoplastic polycarbonate enclosure with hinged LID conforming to IP54 protection class 2 etc, IN REPLACEMENT, complete. Make:- Swadeep02EC8KW3P or equivalent in Indoasian/ABB/L&T |
| 22 | Taking down copper/aluminium point wiring (light, fan , socket or power) complete including fixtures and fittings such as switches, ceiling rose, pendant ,regulators, sockets ,light fittings etc .removing materials to store for keeping in safe custody or for taking credit (credit for items shall be made as per conditions separately) and making good disturbed surfaces of wall, floor etc. |
| 23 | M&L for pointing wiring for One light/fan /call bell point controlled by one switch with 1.5 sqmm (nominal area)PVCinsulated FRLS H, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metallic concealed PVC conduit medium grade of suitable dia as per SSR specification and its accessories including one run of 1.5 sqmm PVC insulated copper conductor cable green in colour for continuous earthing including MS terminal box flushed to wall with 3mm thick laminated hylem sheet top cover for fixing of switch/socket etc all as specified.Note:- surface conduit shall be laid in ceiling portion only. |
| 24 | M&L for pointing wiring for One 3 pin 5 amps socket point on independent board with 1.5 sqmm (nominal area)PVCinsulated FRLS H, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metallic concealed PVC conduit medium grade of suitable dia as per SSR specification and its accessories including one run of 1.5 sqmm PVC insulated copper conductor cable green in colour for continuous earthing including MS terminal box flushed to wall with 3mm thick laminated hylem sheet top cover for fixing of switch/socket etc all as specified.Note:- surface conduit shall be laid in ceiling portion only. |
| 25 | M&L for pointing wiring for One 3 pin 5 amps socket point on same board with 1.5 sqmm (nominal area)PVCinsulated FRLS H, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metallic concealed PVC conduit medium grade of suitable dia as per SSR specification and its accessories including one run of 1.5 sqmm PVC insulated copper conductor cable green in colour for continuous earthing including MS terminal box flushed to wall with 3mm thick laminated hylem sheet top cover for fixing of switch/socket etc all as specified.Note:- surface conduit shall be laid in ceiling portion only. |
| 26 | All as per item No. 23 here-in-before but size of copper conductor 2.5 sqmm for 3 pin 15 Amps switch socket outlet (power point) |
| 27 | S&F switch piano, flush type single pole, one way 5 Amps complete all as specified and directed. |
| 28 | S&F socket outlet 2 in 1,3 pin 5 amps flush type complete all as specified and directed. |
| 29 | S&F Socket outlet 2 in 1,3 pin 5 and 15 Amps flush typecomplete all as specified and directed. |
| 30 | S&F switch piano, flush type single pole, one way 15 Amps complete all as specified and directed. |
| 31 | S&F for in repair Submain wiring alongwith PVC insulated unsheathed multi stranded copper conductor cable of size 2x2.5 sqmm+1x2.5 sqmm earth wire FRLS in and including non metallic concealed PVC conduit medium gradesuitable dia as per SSR specification complete all as specified and directed. |
| 32 | S&F in replacementsheet metal enclosure (DB)double door single pole and neutral 8 way, 240 volt with 200 Amps rated bus barcomplete all as specified and directed. |
| 33 | S&Fin replacementsheet metal enclosure (DB) double door single pole and neutral 12 way,240 volt with 200 Apms rated bus bar complete all as specified and directed. |
| 34 | S &Fin replacementMCB SPN 32 Amps 10KA complete all as specified and directed. |
| 35 | S&Fin replacementMCB SP 6-32 Amps 10 KAcomplete all as specified and directed. |
| 36 | Supply and fixingin replacementLED lights fitting 1x 20W, 220V, AC decorative box CRCA housingtype with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. |
| 37 | Supply and fix in repair LED street light fitting 72 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as directed by Engineer-in-Charge |
| 38 | Supply and fixingin replacementof LED mirror light fitting with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder including connecting up with flexible copper conductor cable of suitable size complete |
| 39 | S&Fin replacementbattery charger 24 VDC, 12 Ah, 10 Amps continuous, overload and short-circuit protection, Natural Air with air ventilation louvers on mental enclosure, suitable for RMU/VCB units complete all as specified and as directed |
| 40 | S&Fin replacementBattery maintenance free sealed battery 120 AH, 12V suitable for HT RMU/VCB relay circuit complete all as specified and as directed |
| 41 | Note :Amount ofcredit for retrieved materials is mentionedin Sch \"A\" Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline. |