| 1 | COMMON ITEMS APPLICABLE FOR JOB \"A\"& \"JOB \"B\":- |
| 2 | Excavation in trenches exc 1.5m wide and not exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thickin soft/loose soil complete all as specified and directed. |
| 4 | Removing surplus soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting pointcomplete all as specified and directed. |
| 5 | M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirementcomplete all as specified and directed.Note- Punned thickness of sand i.e 18 cm shall be considered for measurement purpose. |
| 6 | Supplying and laying un-reinforced precast concrets cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed. |
| 7 | M&LPlain cement concrete 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in benching,coping including weathering slightly rounded or chamfered angles or as per site requirement with necessaryplastering work complete all as specified and directed. |
| 8 | Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittingsandpipes etc complete all as specified and directed. |
| 9 | ITEMS APPLICABLE FOR JOB \"A\" |
| 10 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor of cross sectional area10 sqmm 2 core connecting with panel,DB with suitable size lugs complete all as specified and directed. |
| 11 | All as per item No 8.00 here-in-before but of size 16 sqmm 3 core. |
| 12 | Disconnecting and taking out old rusted pipe and material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 50x6mm, with nut bolt and washers complete all as specified & directed. |
| 13 | Disconnecting and taking out old existing unserviceable PVC cable loop box andsupplying and fixing with pole/wall/pillar PVC cable loop box, size not less than 200 mm x 140 mm x 95 mm, out door type, IP 65including 4 Nos aluminum bus bar ofsize 100mmx5mm mounted on porcelain insulators with oneMCB SP 6 amps 230 volts connected to street light/gate fitting sub main wire and usingFI clamps of size 20mmx3 mm for fixing of PVC cable loop boxwith pole,including nuts,bolts & washers and connecting thecables to bus bars withusing suitable size GI nut, bolts and washers and aluminum lugs etc.,complete all as specified & directed. |
| 14 | M&L for sub main wiringfrom street light/gate light fitting to junction box with two single core 1.5 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC conduit 20 mm diaISI markedbroken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 1.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two run of 1.5 sqmm single core cable and one run 1.5 sqmm earth wire including PVCconduit 20 mm diatogether shall be measured as one unit. |
| 15 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4mpa working pressureand making good to disturbed area i.e road ,path culvertwith PCC 1:2:4 and plaster as per site requirement complete all as specified & directed. |
| 16 | M&L for straight through joints heat shrink type forXLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor cables of size 6 sqmm to 16 sqmmby excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed. |
| 17 | ITEMS APPLICABLE FOR JOB \"B\" |
| 18 | Taking down carefully copper/aluminiumpoint wiring (light, fan,socket or power) complete, including fittings & fixtures such as switches, sockets,ceiling rose, pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good to disturbed surfaces with plaster & matching with the existing colour of wall/floor etc complete all as specified & directed. |
| 19 | M&L for concealed point wiring with 1.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable in and including PVC rigid concealed conduit medium grade of size not less than 25 mm dia ISI marked with all accessories such as tee,bend,joint cover etc, round/ square PVC blocks at junction for batten holders, ceiling rose etc ,screws, gutti / roul plugs PVC all as per site requirementsincluding fixing inside stone walls / brick masonary walls or any type wall /ceilings /floorsetc anodized modular MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyfor mounting of modular switches/ sockets/regulator etc and 1.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cableas continuous earth lead connected to common earth dolly andcolour coding of cables such as Phase- Red, Neutral-Black, and Earth-Greenand making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed by Engineer-in-Charge for the following :- (Note- Cutting, Chasing,drilling in any type of wallfor fixing of concealed conduit and sunken boxes are included in quoted rate. No extra payment shall be made for this.) |
| 20 | One light point controlled by one single pole 5 Amps switch. |
| 21 | One 5 pin socket point 5 Amps on independent board. |
| 22 | One light point controlled by two 2 - way switches, with cables 1.5 sq. mm size |
| 23 | M&L for concealed point wiring with 2.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable in and including PVC rigid concealed conduit medium grade of size not less than 25 mm dia ISI marked with all accessories such as tee,bend,joint cover etc, round/ square PVC blocks at junction for batten holders, ceiling rose etc ,screws, gutti / roul plugs PVC all as per site requirementsincluding fixing inside stone walls / brick masonary walls or any type wall /ceilings /floorsetc anodized modular MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyfor mounting of modular switches/ sockets/regulator etcand 2.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cableas continuous earth lead connected to common earth dolly and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Greenand making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc for One 15 Amp switch socket combination on independent board complete all as specified & directed. (Note- Cutting, Chasing,drilling in any type of wallfor fixing of concealed conduit and sunken boxes are included in quoted rate. No extra payment shall be made for this. |
| 24 | S&F Modular switch , 1 Module single pole one way10 Amps complete all as specified & directed. |
| 25 | S&F Modular socket , 2 Module6 Amps, 5 pin, 230 volts AC complete all as specified & directed. |
| 26 | S&F Modular switch , 1 Module single pole one way16 Amps complete all as specified & directed. |
| 27 | S&F Modular socket , 2 Module6/16Amps, 6 pin, 230 volts AC complete all as specified & directed. |
| 28 | S&F Modular switch two way 10 Amps, 1 module 230 volts complete all specified and as directed. |
| 29 | S&F PVC ceiling rose 65 x 50 mm surface type with 3 terminals 230 volt complete all as specified & directed. |
| 30 | S&F Modular white cover plate with frame, 2 module complete all as specified & directed. |
| 31 | S&F Modular white cover plate with frame, 3 module complete all as specified & directed. |
| 32 | S&F Modular white cover plate with frame, 4 module complete all as specified & directed. |
| 33 | S&F Modular white cover plate with frame, 6 module complete all as specified & directed. |
| 34 | S&F Modular white cover plate with frame, 8 module complete all as specified & directed. |
| 35 | S&F Modular metal flush box 1/2 module complete all as specified & directed. |
| 36 | S&F Modular metal flush box 3 module complete all as specified & directed. |
| 37 | S&F Modular metal flush box 4 module complete all as specified & directed. |
| 38 | S&F Modular metal flush box 6 module complete all as specified & directed. |
| 39 | S&F Modular metal flush box 8module complete all as specified & directed. |
| 40 | S&F LED Light fitting, 4 feet1x20 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable ofsize 1.5 sqmmfrom ceiling rose complete all as specified & directed. |
| 41 | S&F LED mirror Light fitting 2 feet, 10 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 1.5 sqmm from ceiling rose complete all as specified & directed. |
| 42 | S&F LED light fitting outdoor type 10 wattbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable ofsize 1.5 sqmm complete all as specified & directed. |
| 43 | S&F LED light fitting round shape 15 watt 220 volts AC surface type with high efficiency PMMA diffusersoft glare free light complete with drivers, holders,LED lamp suitable for ceiling surface includingconnecting up with three core flexible copperconductor cable of size 1.5sqmmcomplete all as specified & directed. |
| 44 | S&F LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable ofsize 1.5 sqmm from ceiling rose includingbrackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing ofstreet light fitting on poles/ walls/building including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washerscomplete all as specified & directed. |
| 45 | S&F MCB SPN, 40 Amps, 230 V, C- series with breaking capacity of 10 KA complete all as specified & directed. |
| 46 | S&F MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10 KA complete all as specified & directed. |
| 47 | S&FMCCB, 4 poles 415 Volts, 63 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type including connecting up incoming/out going cables connection with suitable lugs and testing completeall as specified & directed. |
| 48 | S&F Exhaust fan steel body AC single phase 230 V of size 380 mm sweep, 900 RPM with blades, frame and louvers,BEE 5 Star rated at any position andat any heightincluding Map Pkt 1& 2 building of HQTC areafrom ground floor to seventh floorandmaking good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed. |
| 49 | S&F BLDC ceiling fans complete with blades, down rods, electronic regulator and accessories, AC single phase 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and remote system to control all the function of fan complete all as specified & directed. |
| 50 | S&F Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe and including drilling holes in any type ofwall, fixing four nos anchor bolts of suitable sizedia and five inch long ,nuts and washer and connected to water pipe line includingtwo nos hot and cold 600 mm long connection pipe, and electric connection testing and making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed. |
| 51 | M&L for concealed sub main wiring with two single core 2.5 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC rigid concealed conduit medium grade of size not less than 25 mm dia ISI marked with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing inside stone walls / brick masonary walls /ceilings /floors etc with 2.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green and making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed. Note- (i) Two runs of single core 2.5 sqmm cable and one run of 2.5 sqmm earth wire including PVC concealed Conduit together shall be measured as one unit. (ii) Cutting, Chasing,drilling in any type of wallfor fixing of concealed conduitfor sub main wiring included in quoted rate. No extra payment shall be made for this. |
| 52 | M&L for concealed sub main wiring with two single core 4 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC rigid concealed conduit medium grade of size not less than 25 mm dia ISI marked with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing inside stone walls / brick masonary walls /ceilings /floors etcwith 4 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green and making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed.Note- (i) Two runs of single core 4.0 sqmm cable and one run of 4.0 sqmm earth wire including PVC concealed Conduit together shall be measured as one unit. (ii) Cutting, Chasing,drilling in any type of wallfor fixing of concealed conduitfor sub main wiring included in quoted rate. No extra payment shall be made for this. |
| 53 | M&L for concealed sub main wiring with two single core 6 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC rigid concealed conduit medium grade of size not less than 25 mm dia ISI marked with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing inside stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green and making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed.Note- (i) Two runs of single core 6.0 sqmm cable and one run of 6.0 sqmm earth wire including PVC concealed Conduit together shall be measured as one unit. (ii) Cutting, Chasing,drilling in any type of wallfor fixing of concealed conduitfor sub main wiring included in quoted rate. No extra payment shall be made for this. |
| 54 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hingedand frame of angle iron 25x25x6mmwith 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GIprotection pipe 15 mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed.Note: (i) The unit rate includes 15 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes galvanised iron wire 4 mm dia from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthingis recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the department. |
| 55 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing 4 mm dia galvanised iron or steel wire complete all as specified & directed. |
| 56 | M&L for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 40x5mm, with nut bolt and washers complete all as specified & directed. |
| 57 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 4 core and connecting up incoming/out going cables connection with suitable size lugsandtesting complete all as specified and directed. |
| 58 | All as per item No-52.00 here-in-before but of size 35 sqmm 3.5core. |
| 59 | All as per item No-52.00 here-in-before but of size 50 sqmm 3.5core. |
| 60 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure and making good to disturbed area i.e road ,path culvertwith PCC and plaster as per site requirement complete all as specified & directed. |
| 61 | S&FMCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in theexisting LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration inLT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirementand connecting up incoming/out going cables connection with suitable size lugsandtesting completeall as specified & directed. |