| 1 | Excavation in trenches n exc 1.5 m wide and n.exc 1.5 m in depth for foundation of pole/stay and laying of UG cable/GI pipe etc and getting out in any type of soil complete all as specified and directed. |
| 2 | M&L returning, filling and including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 3 | Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5mtr above the starting point , complete all as specified anddirected. |
| 4 | Surface excavation not exc 30cm deep and averaging 15cm deep and gettingout in any type of soil complete all as specified anddirected. |
| 5 | M&L Cement concrete M-7.5 (Nominal mix), type D-2, 1:4:8, (using 40 mm graded crushed stone aggregates) in foundation filling and mass concrete, post holes etc complete all as specified and directed. |
| 6 | M&L Cement concrete M-10 (Nominal mix),type C-2, 1:3:6, (using 40 mm graded crushed stone aggregates) in foundation filling and mass concrete, post holes etc complete all as specified and directed. |
| 7 | M&L Cement concrete M-10 (Nominal mix), type C-2, 1:3:6, (using 40 mm graded crushed stone aggregates) in surface channel and drain etc complete all as specified and directed. |
| 8 | Extra for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as specified and directed. |
| 9 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases of columns etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 10 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in slabs, supported on walls, beam and columns in floors and in shelves and the like complete all as specified and directed. |
| 11 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 12 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in beams, chajja, cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and directed. |
| 13 | Steel Formworkto sides of concrete foundations,footings, bases of columns, raft and raft beams,sides and sofits of foundation and plinth beams; and similar works; vertical or to batter for rough finished flat surfaces complete all as specified and directed. |
| 14 | Steel Form work to sides and soffits of floor/roof beam for rough finished flat surfaces of concrete complete all as specified and directed. |
| 15 | Steel Form work to sides of pillars, posts, struts, piers, columns and stanchionsfor rough finished flat surfaces of concrete complete all as specified and directed |
| 16 | Steel Form work to soffits of suspended slabs such as roof slabs, floor slabs etc not exceeding 200mm thick complete all as specified and directed. |
| 17 | Steel Form work to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concretewalls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontalor sloping and similarwork exc 10cm but n exc 20cmwide, forming fair finishes complete all as specified and directed. |
| 18 | M&L TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally forhooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | M&L TMT bars 6 to 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally forhooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 20 | -ditto- here-in-before but 8mm dia and over upto and including 10mm diaas in stirrups, spacers, binders complete all as specified and directed. |
| 21 | S&F for Steel rolling shutter 1.25 mm thickness of laths gear operated type with gear and handle,chain wheel and hand chain as specified including top cover,anchoring rod,hasp and staple and one shop coat of primer and applying two coats of synthetic enamel paint, erected in position as indicated complete all as specified and directed |
| 22 | S&F Galvanised MS wire cloth 0.46mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed. |
| 23 | S&F sheet glass ordinary quality 3mm thick figured pin headed glass with oil putty in area n.exc 0.5 Sqm in each pane, complete all as specified and directed. |
| 24 | M&L Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25mm thick MS Sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing shown on drg welded to GI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etcincluding two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Drg No. CEPZ/C-TD/027/13 sheet 1/4 to 4/4 |
| 25 | Materialand labour for plain cement concretetypeB-1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs ,water troughs and the like including weathering, slightly rounded or chamfered angles andthroating, complete all as specified and directed. |
| 26 | M&L for roof treatment with the following specicification - (a)15 mm thick rendering in CM 1:4 with WPC @3% by weight of cement (b) applying evenly one coat of blown hot bitumen of grade 85/25 @ 1.2 kg per sqm on primed surfaces. (e) Applying a layer of APP based polymeric membrane 3mm thick (minimum) weighting 3.6 kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160 gms per sqm top of membrane with granular finish. The overlap shall be minimum 100mm on transverse direction and 150 mm on longitudinal direction and sealing overlap by torch application . |
| 27 | Demolition of cement concrete in of any description in any position complete all as specified and directed. |
| 28 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed. |
| 29 | M&L for 25 mm thick PCC type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in flooring complete all as specified and directed . |
| 30 | M&L for 100 mm thick PCC type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed . |
| 31 | M&L for 75 mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed . |
| 32 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; and demolition of existing tiles any shape complete all as specified and as directed. |
| 33 | M&L for Spreading and levelling in layers n exc. 25 cm thick and watering and well ramming under floor complete all as specified and directed. |
| 34 | M&L Hardcore of broken stone or bouldersof gauge n. exc. 63mm, deposited spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surfacecomplete all as specified and directed. |
| 35 | M&L Anti-termite treatment tothe soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 36 | M&LAnti-termite treatment to backfilling in contact with foundation at the rate of 7.5 ltr of emulsion per sqmon vertical surface complete all as specified and directed. |
| 37 | M&LAnti-termite treatment to the top surface of filled earth at the rate of 5 Ltr per sqm of surface complete all as specified and directed. |
| 38 | M&L for Durastone / Endura heavy duty vitrified tiles of size 300mm x 300mm x 9-10mm thick set jointed and pointed in neat cement slurry in floors with grey cement over and including 15mm thick cement screed bed or bedding layer in CM 1:4 including 75mm thick cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base, complete all as specified and directed |
| 39 | M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n . Exc 0.18 sqm ,in floors & Skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match includind sceeding 15mm thick in cement mortar 1:4 complete all as specified and directed. |
| 40 | M&L flush pointing to brick walls in Cement Mortar 1:3 complete all as specified and directed. |
| 41 | M&L for rendering 10mm thick in cement mortar 1:6, on fair faces of brick work or concrete surfaces , finished even and smooth without using extra cement, preparation of new plasteredsurfaces of walls and applying 1mm thick wall care putty, one coat of primer andtwo coat oil emulsion distemperon walls complete all as specified and directed . |
| 42 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed |
| 43 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 incl complete all as specified and directed |
| 44 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 incl complete all as specified and directed |
| 45 | All as per item No above but except brickscomplete all as specified and directed |
| 46 | M & Lfor Half thick Brick wall work curved on plan in any radius with old size bricks built in cement mortar 1:4and external pointed flush in same mortar as the work proceeds complete all as specified and directed. |
| 47 | M&L For preparation of New Plastered surfaces and applying two coats of Acrylic emulsion (Apex) over a coat of primer complete all as specified and directed. |
| 48 | M&L for 450mm bore reinforced concrete pipes class NP-2, laid and jointed complete with collars complete including laying with haunching and bedding 100mm thick complete all as specified and directed. |
| 49 | M&L for Providing precast cement concrete as in manholes/Drain covers 1:2:4 mix type B-1, using 20mm graded crushed stone aggregate complete all as specified and directed. |
| 50 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement mixed with liquid ater proofing compound @ 3% of cement weightcomplete all as specified and directed |
| 51 | M&L 75 mm thick PCC, type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement. complete all as specified and directed |
| 52 | M&L forrendering 5 mm thick in CM (1:3) finished surface even andsmooth w/o using extra cement in ceiling and applying three coats of white wash on ceilingcomplete all as specified and directed |
| 53 | Supply only liquid Water Proofing Compound. complete all as specified and directed |
| 54 | Supply and layingfor XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade,of size 16 Sqmm, 4 corecomplete all as specified and directed by Engr-in-Charge .Note : Earth work including excavation, returning filling, removing, DWC pipe covering for mechanical protection of cable etc will be measured and paid for separately under respective items of schedule. |
| 55 | Supply and fix for DWC high density polythylene pipes having dia 63/50 as per site requirement having corrugation on the wall and plain surface on the wall conforming to IS : 14930 (Part-I & II) for protection ofunderground cable laid along pole/along wall/in PCC on GL/and including all fitting as required complete all as specified anddirected. |
| 56 | Point wiring with 1.5 Sqmm FRLS, PVC insulated andunsheathed multi stranded flexible copper conductor cable inand incl rigid PVC conduitconcealed medium grade with pressed mild steel terminal boxes(sheet not less than 1.6 mm thick) duly painted with a coat of red oxide primerwith suitable thickness plastic laminated sheet cover 3mm thickofadequate size for one light or one fancontrolledby one switch incl 1.5 Sqmm FRLS, PVC insulated andunsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge.Note: a) Rate for cutting chases for conduits and sinking for boxes and making good to wall, floors deemed to be included in each point etc (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary point with proper fixing clips and no extra cost shall be paid for the job etccomplete all as per specified and directed. (c) colour coding is to be maintained. (Ph-Red, N-Block, Half-yellow, Earth-Green). |
| 57 | All as per item No 85 but for one 3 pin 5 Amp socket outlet on independent board complete all as per specified and directed. |
| 58 | All as per item No 85 but for one 3 pin 5 Amp socket outlet on same board complete all as per specified and directed. |
| 59 | Point wiring with 2.5 sqmm FRLS, PVC insulated andunsheathed multi strandedflexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes(sheet not less than 1.6mm thick) of adequate size with suitable thickness plastic laminated sheet cover 3mm thick for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS, PVC insulated and unsheathed copper conductor cable(multistranded)as earth wire to common earth dolly, complete all as per specified and directed. |
| 60 | S & F for switch piano flush type one way 5 amps SP complete all as specified and directed.Make: Havells (REO) or technocommerically equivalent make ofcona/SSK. |
| 61 | S & F for switch piano flush type one way 15 amps SP complete all as specified and directed.Make: Havells (REO) or technocommerically equivalent make ofcona/SSK. |
| 62 | S & F socket outlet3 pin 5 amps flush type complete all as specified and directed. Make: Havells (REO) or technocommerically equivalent make of cona /SSK. |
| 63 | Supplying &Fixing socket out let, 6 pin, 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed. Make: Havells (REO) or technocommerically equivalent make of cona /SSK. |
| 64 | Supply and fix LED Bulb 9W complete all as specified and directed. |
| 65 | S&FLampholder, PVC/Polycarbonate type with bakelite back plate having matching colour to holder suitable for angle/batten fittings complete all as per specified and directed. |
| 66 | S&F ceiling rose surface 65x50mm three terminal with bakelite back plate complete all as specified and directed. |
| 67 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose of complete all as specified and directed |
| 68 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH complete all as specified and directed. |
| 69 | S&F MCB SPN 32 Amps with 10KA breaking capacity of \"B\" series in distribution board complete all as per specified and directed. |
| 70 | S&F MCB SP 6-32 Amps with 10KA breaking capacity of \"B\" series in distribution board complete all as per specified and directed. |
| 71 | S&FMCB TPN 63 Amps, 415 Volts, 10 KA breaking capacity of B series in distribution board complete all as specified and directed. |
| 72 | Supply and fixingceiling fans copper wounded complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all asspecifiedand as directed. |
| 73 | S&Fsheet metal powder enclosure powder coated versatile double door 4 way (SPN) distribution board , 415Volt, 50Hz AC with neutrallink , earth bar,complete all as specified anddirected. |
| 74 | S&Fsheet metal powder enclosure powder coated versatile double door 4 way (TPN) distribution board , 415Volt, 50Hz AC with neutrallink , earth bar,complete all as specified anddirected. |
| 75 | M&L for Sub main wiringin repair/replacement complete with two run of6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductorFRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface concealed(ISI marked) with wall thickness not less than 1.8mm complete with all accessories including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly . Note :-Two run of 6 Sqmm cable incl one run of earth wire and PVC conduit and its accessories shall be measured and paid as one lengthcomplete all as specified and directed. |
| 76 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanizediron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thickRCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced withsuitable handle and angle iron frameand necessary excavation and earth work in any type of soil etc. complete all asspecifiedand as directed includingtesting on completion. (Note: The rate quoted include cost of min 7.5 metre earthling wire .) |