| Sl. No. | Item Description |
| 1 | M&L for dismantling the solar water heater system of capacity 350/400 Ltrs for replacing the unserviceable spare parts, accessories, etc. including neccessory connection and testing, complete all as specified and directed.Note :- Spare parts/ accessories will be paid under the respective items of this BOQ. |
| 2 | M&L for servicing of the solar water heater 350/400 LPD capacity as existing indirect solar water heating system and making good of any leakage, replacement of gaskets etc. and testing, complete all as specified and directed.Note :- All spare parts will be measured and paid separately under respective items of this BOQ. |
| 3 | Reassembling of complete solar system including testing and commisioning, complete all as specified and directed. |
| 4 | S&F toughened glass of size 1.9 mtr x 0.9 mtr and 3.2mm thick, complete all as specified and directed. |
| 5 | S&F flat plate collector of size 1.9 mtr x 1.1 mtr as per sample of existing solar water heating system and testing, complete all as specified and directed. |
| 6 | S&F neoprene gasket suitable for solar water heater of capacity 500/300 ltrs, complete all as specified and directed. |
| 7 | S&F temperature gauge as per sample, suitable for solar water heater of capacity 350/400 ltrs, complete all as specified and directed. |
| 8 | S&F stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 20mm bore, complete all as specified and directed. |
| 9 | S&F stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 25mm bore, complete all as specified and directed. |
| 10 | S&F rotational moulded polyethylene water storage make up tanks (cylendrical vertical with closed top), three layered, white in colour of capacity 300 Ltrs, hoisted and fixed in position, complete all as specified and directed. |
| 11 | Reapair, descaling of solar water heater of capacity 350/400 Ltrs by chemical, cleaning of solar panel including welding work for repair of leakage, complete all as specified and directed.Note :- Cost of welding shall be deemed to include in the quoted rates. |
| 12 | M&L for Glycol solvent material for indirect heating, complete all as specified and directed. |
| 13 | M&L for mild steel angle iron/ MS plate works including nuts, bolts, washers, welding, drilling holes for bolts in any shape or size as indicated or directed of making staging of the tank and painting with one coat of red oxide zinc chrome primer and one under coat and one finishing coat of aluminium paint, complete all as specified and directed. |
| 14 | M&L for submain wiring with two single core2.5 Sqmm PVC insulated FRLS multistrand copper conductor cable, drawing into and including rigid non metallic PVC casing & caping, ISI marked with all fittings and fixing accessories and one single core 2.5 Sqmm FRLS multistrand copper conductor cable as continuous earth wire, complete all as specified and directed. |
| 15 | M&L for submain wiring with two single core4.0 Sqmm PVC insulated FRLS multistrand copper conductor cable, drawing into and including rigid non metallic PVC casing & caping, ISI marked with all fittings and fixing accessories and one single core 4.0 Sqmm FRLS multistrand copper conductor cable as continuous earth wire, complete all as specified and directed. |
| 16 | M&L for cladding of existing GI pipe of 20mm dia by replacing insulation glass wool with chicken wire mesh, aluminium sheet 26 gauage, thickness 50mm, complete all as specified and directed. |
| 17 | S&F vent pipe using medium grade GI tubing of 20mm dia, fixed to wall/ ceiling upto level not less than 15cm from OH tank top level including necessary fittings, fixtures, clamps etc, complete all as specified and directed. |
| 18 | S&F 15mm dia GI tubing, medium grade, fixed to wall/ ceiling including necessary fittings, fixtures, clamps etc, complete all as specified and directed. |
| 19 | S&F \"C\" clamp for collector, complete all as specified and directed. |
| 20 | S&F EPDM hose pipe, complete all as specified and directed. |
| 21 | S&F flange nipple of 20mm or suitable size for solar water panel of any size, complete all as specified and directed. |
| 22 | S&F of hose clips of size 1 inch, complete all as specified and directed. |
| 23 | S&F in replacement of solar sunglow water tank of capacity 350/400 ltrs, complete all as specified and directed. |
| 24 | Repair/ maintenance excluding spares but including regular maintenance of the Sewage Treatment Plant of capacity 20 KLD installed at Old Medical Complex under GE (North) including carrying out complete maintenance/ servicing/ repair as required of all the sub systems viz controlpanels, compressor blower, pump motors, lamella plant, filter press, filtration plant & sodium hyprochlorite dosing plant (with all the accessoires), breakdown maintenance and replacement of unserviceable parts and refixing the same, complete all as specified and directed. |
| 25 | M&L for emptying, cleaning of sand media filter of 20 KL per day STP including welding work etc. as required, complete all as specified and directed.Note :- Cost of welding shall be deemed to include in the quoted rates. |
| 26 | M&L for epoxy coating and sand media filter vessel internally suitable 20 KL per day STP, complete all as specified and directed. |
| 27 | S&F in replacement of filter media of sand media filter unit of 20 KL per day STP as described by precipitation including testing of the same, complete all as specified and directed. |
| 28 | S&F in repalacement of existing gasket and fasterner of sand media filter unit including nuts, bolts and washers, complete all as specified and directed. |
| 29 | M&L for emptying and cleaning of activated carbon unit of 20 KL per day STP etc, complete all as specified and directed. |
| 30 | M&L for expoxy coating of activated carbon unit of 20 KL per day STP vessel internally suitable 50 Cum per day STP, complete all as specified and directed. |
| 31 | M&L for replacement of filter media of activated carbon unit of 20 KL per day STP suitable 50 Cum per day STP precipitation includingtesting of the same, compete all as specified and directed. |
| 32 | S&F in replacement of existing gasket and fasterner of active carbon unit including nuts, bolts and washers, complete all as specified and directed. |
| 33 | Dismantling the unserviceable parts of sewage treatment compressor blower and replace with new one including testing after completion, complete all as specified and directed. |
| 34 | S&F in replacement of suction filter, suitable for sewage treatment compressor blower, complete all as specified and directed. |
| 35 | S&F in replacement of gears with Hub complete with hardware, suitable for sewage treatment compressor blower, complete all as specified and directed. |
| 36 | S&F in replacement of \"V\" belt, suitable for sewage treatment compressor blower, complete all as specified and directed. |
| 37 | S&F in replacement of gear oil No 90, suitable for sewage treatment compressor blower, complete all as specified and directed. |
| 38 | S&F in replacement of oil seal and gasket set, suitable for sewage treatment compressor, complete all as specified and directed. |
| 39 | S&F in replacement of set of rotor with shaft for sewage treatment compressor blower, complete all as specified and directed.Make :- Everest or equivalent as per ISI Marked as approved by GE. |
| 40 | Collection of sewage water sample (Monthly) from Sewage Treatment Plant of 20 KL per Day at Old Medical Complex and carry out following test from Govt Laboratory of NABL approved laboratory, complete all as specified and directed.Note :- The following parameters required to test and submit to test report to Engineer-in-Charge on monthly basis :- (i) B.O.D (ii) C.O.D (iii) T.S.S (iv) PH Values (v) Fecal Coliform (vi) Odour (vii) Nitrogen total (viii) Phasphoras. |
| 41 | Collection of sewage water sample (Monthly) from Sewage Treatment Plant of 20 KL perDayat 71 Sub Area and carry out following test from Govt Laboratory of NABL approved laboratory, complete all as specified and directed.Note :- The following parameters required to test and submit to test report to Engineer-in-Charge on monthly basis :- (i) B.O.D (ii) C.O.D (iii) T.S.S (iv) PH Values (v) Fecal Coliform (vi) Odour (vii) Nitrogen total (viii) Phasphoras. |
| 42 | M&L for disconnection of electrical connections, de-coupling from non clogging centrifugal pump, unscrewing foundation nuts, bolts & washers of squirrel cage induction motor from foundation base plate and taking out carefully for repair motor of upto 5 HP (3 Phase, 415 Volts, 50 C/S, AC Supply) of any make and re-fixing after repair, jointing, coupling with pump electrically connected setting proper alignment with pump with old/new nuts, bolts & washers, rubber coupling joint and testing, complete all as specfied and directed.Notes :- (i) The cost of transportation of the defective motor from site to workshop and back shall be deemed to include in the quoted rates. (ii) Repair of motor will be measured & paid separately under respective item of this BOQ. (iii) Replacement of bearing/ cooling fan will be measured and paid as supply only. |
| 43 | M&L for rewinding of burnt squirrel cage induction motor upto 5 HP 3 Phase, 415 V, 50 Hz of any make with super enamelled copper wire as per existing size, specification after dismantling/ cutting out burntwindings from stator assembly and cleaning slots properly with replacement of insulating slots packing sleeves papers & re-assembling stator and rotor after replacement of worn out spares/ matching works including painting with two coats of synathetic enamelpaint over a coat of red oxide primer after preparation of motor external surface, fixing new terminal connector block, replacement of old bearing at both front & rear and greasing, complete all as specfied and directed.Note :- Bearing, PVC cooling fan, oil seal required new for replacement shall be deemed to include in the quoted rates. |
| 44 | Dismantling non clogging centrifugal pump 5 HP overhauling, servicing cleaning throughly cases impellers, shaft bearing housing gland packing descaling all dirt and assembling after repair with required machining works (if any) new key new both end bearings, old bearing cover, new gland packing with old gland cover, new impeller stuffing box stud, rubber coupling including applying two coats of synthetic eneamel paint over a coat of red oxide primer after preparation of pump external surface, complete all as specified and directed.Note :- Impeller and bearing required new for replacement will be measured and paid separately as supply only. |
| 45 | S&F in replacement of foot valve of suction pipeline (Non clogging pump set), complete all as specified and directed. |
| 46 | S&F in replacement of CI impeller, suitable for non clogging pump 5 HP, complete all as specified and directed. |
| 47 | Cleaning of sewage well including chocking of all incoming sewage line entering to sewage well for dewatering and desuldging of slurry of sewage pump, complete all as specified and directed. |
| 48 | M&L for desludging of slurry using buckets and pulleys of depth total depth 7.5 mtr slurry average depth 2.5 mtr including depositing at a distance not exceeding 1000 mtr from starting point of sewager pump, complete all as specified and directed. |
| 49 | M&L for de watering, desludging and desilting of septic tanks, manholes, sludge chambers and the like by mannual or mechanical means depositing in tankers and disposal of the same at the placeto a distance exc 2 KM but not exc 3 KM where directed and sprinkling of bleaching on the disposed material @ 3 KG per Cum, complete all as specified and directed.Note :- The cost of transportation, bleaching powder shall be deemed to include in the quoted rates. |
| 50 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) in coping of poles, foundation for poles, struts, posts etc. including necessary form work, finished the exposed surfaces fair and even without usingextra cement, complete all as specified and directed. |
| 51 | M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete for pole / stay / post etc, complete all as specified and directed. |
| 52 | S&F in replacement of LED flood light fitting of 90 Watt, Glatt a high performance flood light with pressure die cast IP-66 housing, secondary lens with 120 lm/W efficency, CRI 7, PF >0.90 and superior aesthetics suitable for various applications, fixing on pole and including of necessary GI bracket of suitable dia including FI clamps, bolts, nuts and washers with provision of 2 runs of cable PVC insulated single core unsheathed 1100 volts grade 2.5 Sqmm multistranded with aluminium conductor from existing LT electric supply to light fittings, complete all as specified and directed. |
| 53 | M&L for servicing and overhauling of 3 HP to 7.5 HP induction motor including varnishing the stator and replacing the worn out drive end/ driven end bearings and greasing, re-assembling and testing, complete all as specified and directed. |
| 54 | M&L for servicing and overhauling of upto 2 HP induction motor including varnishing the stator and replacing the worn out drive end/ driven end bearings and greasing, re-assembling and testing, complete all as specified and directed. |
| 55 | M&L for servicing and over hauling of 1 HP induction motor including varnishing the stator and replacing the worn out drive end/ driven end bearings and greasing, re-assembling and testing, complete all as specified and directed. |
| 56 | S&F in replacement of rubber hose set for DG set of capacity 15 KVA,complete all as specified and directed. |
| 57 | Dismantling / taking out old unserviceable self starter assembly 24 Volts from the DG set and M&L for rewinding with super enamelled copper wire of existing size & insulating the field coil assy, replacing brush assy ofthe self starter assembly 24 Volts and refixing the same after repairs and testing, complete all as specified and directed. |
| 58 | S&F in replacement of battery charger of capacity 6 Amps, 12 Voltsfor DG set, complete all as specified and directed. |
| 59 | S&F in replacement aganist repairs of stop solenoid / shut off valve of capacity 15 KVA DG Sets of existing make alongwith screen filterincluding wiring connecting to panel circuit, starting and testing on load, complete all as specified and directed. |
| 60 | S&F in replacement of thermostat element alongwith complete assy for DG set connection and testing, complete all as specified and directed. |
| 61 | Repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacturer\"s guidelines for DG Set of various capacity upto 15 KVA capacity of any make including replacement of worn out and unserviceable Ó\" rings / shutt off valve/ Plungers, complete all as specified and directed. |
| 62 | S&F in replacement of control assembly for DG Set of capacity 15 KVA with necessary modification to control wiring, replacement of controll relays, programming with all the parameters for safety protection and running suitable for the existing DG sets, complete all as specified and directed. |
| 63 | S&F in replacement of PCB assembly for DG Set of capacity 15 KVAwith necessary modification to control wiring, replacement of control relays, programming with all the parameters for safety protection and running suitable for the DG sets, complete all as specified and directed. |
| 64 | S&F in replacement of Automatic Voltage Regulator, suitable for 15 KVA DG Set of make M&Mahindra / Greaves, connecting with panel circuit, starting and testing on load, complete all as specified and directed. |
| 65 | S&F in replacement of Megnetic Pickup Sensor, suitable for 15 KVA DG Set of make M&Mahindra / Greaves, connecting with panel circuit, starting and testing on load, complete all as specified and directed. |
| 66 | S&F in replacement of Oil Pressure Sensor, suitable for 15 KVA DG Set of make M&Mahindra / Greaves, connecting with panel circuit, starting and testing on load, complete all as specified and directed. |
| 67 | S&F in replacement of Coolant Tempetarure Sensor, suitable for 15 to 30 KVA DG Set of make M&Mahindra / Greaves, connecting with panel circuit, starting and testing on load, complete all as specified and directed. |
| 68 | M&L for opening / taking down radiator of DG Set of any type and make and capacity 15 to30 KVA, cleaning / descaling with using air compressor and cleaning with detergent etc. and examining of water leakage of the same after cleaning, descaling and repairing of leakage if any, repair the same with using welding/brazing etc. including replacement of all connecting parts i.e. radiator hose pipe with clamps, bolts, nuts, washers, rubber bush, packing material etc. and re-assembling the radiator, fitting in DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation, complete all as specified and directed. Notes :-(i) The rates of replaced spares / parts shall be deemed to include in quoted rates. (ii) The cost of transportation (to and from) for all kind of necessary equipment and T&P shall be arranged by the contractor to complete the job at site and cost of the same shall be deemed to include in the quoted rates. |
| 69 | Cleaning of diesel tank of various capacity DG Set, inside/ out side oftank complete with drain out DHPP(N) and cleaning tank and applying two coats of synthetic enamel paint on out side of tank and testing, complete all as specified and directed. |
| 70 | M&L for removing of oil deposits and cleaning all the external surface of the DG Sets of capacity 15 KVA alongwith enclosures and connected pipe lines from oil/ paint/ corrosion flakes completely and applying two coats of heat retardant paint, complete all as specified and directed. |
| 71 | M&L for removing of oil deposits and cleaning all the external surface of the DG Sets of capacity 25 KVA alongwith enclosures and connected pipe lines from oil/ paint/ corrosion flakes completely and applying two coats of heat retardant paint, complete all as specified and directed. |
| 72 | M&L for removing of oil deposits and cleaning all the external surface of the DG Sets of capacity 30 KVA alongwith enclosures and connected pipe lines from oil/ paint/ corrosion flakes completely and applying two coats of heat retardant paint, complete all as specified and directed. |
| 73 | S&F in replacement of 3 Phase digital multi function meter with suitable accessories and fixing arrangements, complete all as specified and directed. |
| 74 | S&F in replacement of selector switch, suitable for 415 Volts, complete all as specified and directed. |
| 75 | S&F in replacement of LED type phase indicator to be fitted on panel (R.Y.B as per site requirement), complete all as specified and directed. |
| 76 | S&F in replacement of Digital Type Voltmeter, 0-500 Volts with selector switch, 3 phase, complete all as specified and directed. |
| 77 | S&F in replacement of Digital type Ammeter, 0-500 Amps with 3 Nos CT coils and selector switch, 3 phase, complete all as speicified and directed. |
| 78 | Supply, installation, testing and commissioning in replacement offactory made, outdoor type, CPRI approved, dust and vermin proof, LT panel board, front opening (double shutter) with locking arrangements of suitable size made out of 3.15mm thick CRCA sheet (IS-8623) with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection Class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC, 415 Volts, 3 Phase, 50 Hz, 4 wire system with suitable of PVC copper conductor for internal wiring, thimbles gland, cable lugs, nuts, bolts, washers etc. including PCC foundation (PCC 1:2:4 type B-1) of suitable size as per panel board, 0.5 Mtr above ground level grouting and bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron including internal prewiring complete all as specified and directed with the followings :-100 Amps capacity copper bus bar strip - 4 Nos. of suitable length, INCOMING :-(i) MCCB, FP, 63 Amps, capacity 16 KA, 4 Pole, 3 Phase, 415 Volts with thermal magnetic release (Ics = 100% Icu) - 01 No.(ii) Voltmeter 0-500 Volts with selector switch (Digital type) - 01 Set. (iii) Ammeter 0-200 Amps with 3 Nos CT coils and selector switch (Digital type) - 01 Set.(iv) Indicator lamp neon/ LED type, RYB - 01 Set of three.OUTGOING :-(i) MCCB, FP, 40 Amps, capacity 10 KA, 4 Pole, 3 phase, 415 Volts - 02 Nos. (01 For Office and 01 For single accn and 01 No. spare).(ii) MCB TPN, 40 Amps, capacity 10 KA, single phase - 02 Nos. |
| 79 | All as per serial item No. 78.00 here- in-above but comprising of the following items including internal prewiring complete :- 100 Amps capacity copper bus bar strip - 4 Nos of suitable length. INCOMING :-(i) MCCB, FP, 40 Amps, capacity 10 KA, 4 Pole, 3 Phase, 415 Volts with thermal magnetic release (Ics = 100% Icu) - 01 No.(ii) Voltmeter 0-500 Volts with selector switch (Digital type) - 01 Set. (iii) Ammeter 0-500 Amps with 3 Nos CT coils and selector switch (Digital type) - 01 Set.(iv) Indicator lamp neon/ LED type RBY - 01 Set of three.(v) copper bus bar capacity 63 Amps for Phase, RYB- N - 4 Nos.OUTGOING :-(i) MCB SPN 40 Amps, capacity 10 KA, single phase - 08 Nos (spare- 1 Nos) |
| 80 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade of size 25 Sqmm 3.5 Core, complete all as specified and directed. |
| 81 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade of size 10 Sqmm 2 Core, complete all as specified and directed. |
| 82 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade of size 35 Sqmm 3.5 Core, complete all as specified and directed. |
| 83 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade of size 50 Sqmm 3.5 Core, complete all as specified and directed. |
| 84 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade of size 70 Sqmm 3.5 Core, complete all as specified and directed. |
| 85 | Excavation in trenches in any type of soil, not exc 1.5 mtr deep and not exc 1.5 mtr wide for laying of underground cable, electric pole and getting out, complete all as specified and directed. |
| 86 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. |
| 87 | Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 88 | M&L for dry sand as in cushioning to underground cables, provided with a layer of sand 8cm thick before laying the cable and 15cm thick after laying cable and stretching the cable, complete all as specified and directed. |
| 89 | Supply and laying of brick Class ‘B’ covering as mechanical protection to cable with well burnt, complete all as specified and directed. |
| 90 | M&L for replacement of 50mm bore galvanised iron tubes, medium grade for cable protection at site, complete all as specified and directed. |
| 91 | M&L for 40mm bore GI tubing, light grade with all fittings, fixed in wall and floor or fixed to pole with suitable means. complete all as specified and directed. |
| 92 | M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip of size 32x6mm as earth lead as shown in electrical plate No. 3 of SSR Part I, connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in any type soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 (using 20mm graded stone aggregates), funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and precast earth pit cover of 50mm thick made of RCC (1:1.5:3) tyep A-1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc. mesh, charcoal and common salt in alternate layer of 15cm thick including taking up/down old unserviceable existing earthing, complete all as specified and directed. |
| 93 | Surface dressing and cutting of vegetation bushes etc. including cleaning, maintenance of DG Sets / STP installations clean regularly, complete all as specified and directed. |
| 94 | M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 95 | M&L for mild steel work for posts, struts, purlines, rafter and similar works etc. including necessary drilling, bolting or rivetting etc. and similar work, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 96 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in platform, floor etc, complete all as specified and directed. |
| 97 | S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap, fixed with \"L\" or \"J\" type or cranked hooks, bolts as in roof etc, complete all as specified and directed. |
| 98 | Supply, fixing, testing and commissioning of lithium based integrated solar street light 16 Watt, the system shall include FRP Housing 16 Watt Hi brightness LED light (120-140 luminous/W), operating voltage 11.1/12.8 Volt, IP-66 complaint, driver efficiency 85% to 90%, CRI > 80 CCT 6500K, toughen glass acrylic cover, MPPT/PWM base charge controller with hi-efficiency LED driver design with/without dimming function as per IEC standards, Hi-efficiency Mono/poly crystalline solar panel, lithium battery, 2 days autonomy, 19.8 AH, DOD 90 to 95%, 25/30 wp solar panel, complete all as specified and directed. |
| 99 | S&F galvanised iron, medium grade (GI) Pole 80mm dia 5 mtr height excluding planting depth for solar street light including with two coats of aluminium paint over one coat of red oxide primer, excavation, earth work, foundation of pole with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) of size 450mm x 450mm x 1000mm deep, complete all as specified and directed.Note :- The rates for earth work, excavation, painting and cement concrete shall be deemed to include in the quoted rates. |
| 100 | S&F sintex box of size 280mm X 170mm X 130mm, Hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cable for 1 Phase and Neutral, fixed on pole with the help of MS nuts, bolts and MS clamps - 2 Nos of size FI 40x4mm with one No. MCB SP 10 Amps capacity, mounted on din rail inside box. The work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1.5 Sqmm 3 Core flexible PVC insulated copper cable from junction box to connector of street light, complete all as specified and directed. |
| 101 | S&F in replacement of energy saving LED garden light fitting, pressure die cast, powder coated housing with PC diffuser, efficient high output LED with IP-65 protection, decorative, bollard type of capacity 9/10 Watt with opal diffuser & aluminium reflector complete with all accessories and fixing arrangement on PCC block of size 30cm x 30cm alogwith fixing nuts, bolts and PVC insulated aluminium conductor, stranded type of size 4 Sqmm 2 Core including taking down old unserviceable garden light fittings of any type and wattage,complete all as specified and directed. |
| 102 | S&F Retrofit Emmission Control Device (RECD) for 15 KVA DG Set, complete all as specified and directed.Make :- Mahindra or as per existing make. |
| 103 | S&F Retrofit Emmission Control Device (RECD) for 25 KVA DG Set, complete all as specified and directed.Make :- Mahindra or as per existing make. |
| 104 | M&L for shifting of stand by DG Set 11/0.433 KV, copper wound, 15 KVA DG Set from existing location of GE (North) office to near Office store shed premises of GE (North) upto 50 mtr surrounding area as directed with the help of recovery crane for loading & unloading purpose & carrying vehicle for transportation purpose including disconnecting of all electrical connection as per directed by OEM and reconnecting the same after shifting and testing, commissioning of complete DG Set, complete all as specified and directed. |
| 105 | Supply, fixing and testing of Solar Hot Water Heating System indirect type with heat exchange provision of capacity 100 LPD with four compartments (25 Ltrs each) with electric backup (upto 2/1.5 KW) heater of suitable capacity to give/achive temperature of 60 degree Centigrade to 80 degree Centigrade as per manufacturer\"s design, suitable flat plate collectors having insulation of rock wool / mineral wool 50mm thickness at bottom and 25mm thickness on sides with toughened tempered glass of 4mm thick and cladding with aluminium sheet 26 SWG, hot water storage tank capacity as per manufacturer\"s recommending of suitable gauge thick stainless steel plate (having insulation of rock wool/ mineral wool 100mm thick and cladding with aluminium sheet 24 SWG), cold water storage tank of capacity with ball valve of suitable size, float ball valve with stands for collectors, staging of suitable height (for easy flow of water) for hot water and cold water tanks made out of 50x50x6mm angle iron with PCC 1:2:4 type B-1 as required complete with temperature guage 0 to 100 degree centigrade, brass gate valve in hot and cold water pipes, horizontal type stainer on incoming water line, complete all as specified and manufacturer\"s instructions and as directed.Make :- Inter Solar / Su Solar Tech / TATA BP Solar / Bipin Industries |
| 106 | M&L for galvanised iron pipe, medium grade, 20mm bore, ISI marked with necessary fittings such as tees, elbows, bends, reducers, unions etc, fixed along the wall/ floor/ roof including covering with insulation all around with 25mm thick bonded mineral wool preformed \"SNAPON\" pipe sections of density 144 KG/Cum, conforming to IS:9842 of rock wool/ mineral wool, chicken mesh and cladding with 26 SWG aluminium sheet including chasing/ cutting of wall as required, complete all as specified and directed. |
| 107 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail