| 1 | Excavating over areas, not exceeding 1.5m deep and getting out in any type of soil complete all as specified and as directed. |
| 2 | M&L for Hardcore of gauge exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and as directed. |
| 3 | M&L PCC (1:4:8) as in type D2 (40mm graded aggregate) Cement concrete in foundations, filling and mass concrete complete all as specified and as directed. |
| 4 | M&L for Pre-cast cement concrete block masonry PCC (1:3:6) type C-1 (using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and set in CM (1:6) complete all as specified and as directed. |
| 5 | M&L for rendering 15 mm thick in Cement mortar (1:4) on fair faces of brick/concrete surfaces finished even and smooth without using extra cement over and including applying two coats ofcement based paint onwalls over a coat of primer complete all as specified and as directed. |
| 6 | M&L for Cement concrete (1:2:4)type B-1 (20mm graded aggregate) as in base of 150mm thick complete all as specified and as directed. |
| 7 | M&L 15mm nominal bore mild steel galvanised water tubing, medium grade (ISI) marked, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed. |
| 8 | S&F in 15mm bore Chromium plated Fancy type Bip taps, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 9 | S&F for rotational moulded polyethylene water storage tanks of 2000 litres capacity (cylindrical, vertical, with closed top), triple-layered, white in colour, hoisted and fixed in position, all as specified in SSR Part I, complete all as specified and as directed. |
| 10 | S&F for 150 mm PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, with all fittings, fixed to walls as rainwater pipes, including bends of any radius as required for connection with the tank, complete all as specified and as directed. |
| 11 | Removing excavated material/soil to a dist. n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and as directed. |