Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | AIR CONDITIONER |
| 2 | M&L for servicing of Split Air Conditioner (1.5 TR / 2.0 TR capacity) by taking down from existing position/location and re-installation after servicing, including:(i) Checking serviceability of all electrical and electronic components such as power circuits, relays/contactors, wiring kit, thermostat sensors/switches, knobs, remote control unit including PCB, indoor fan motor, blower, etc.(ii) Attending to loose/defective electrical connections and ensuring the AC unit is restored to satisfactory working condition after necessary servicing (excluding replacement of major parts).(iii) Washing and cleaning of indoor cooling coil using a proper water collection bag to prevent spillage on floor.(iv) Cleaning of outdoor condenser coil and fittings, first by air blower, then by spraying approved non-acidic de-scaling / coil-cleaning chemical (such as MPC-AC-102 or equivalent of best quality), followed by thorough washing with fresh water using a high-pressure water gun until all chemical residues are removed.(v) Testing, trial run and commissioning, complete all as specified and as directed.NOTES(1) Water collection bag to prevent spillage during servicing shall be provided by the contractor at no extra cost.(2) The quoted rate shall be inclusive of supply and use of all de-scaling / coil-cleaning chemicals, tools, plants, consumables, water, minor materials, labour, transportation, etc., required to complete the work.(3) Replacement of parts/spares, if required, shall be measured and paid separately under the respective items hereinafter. |
| 3 | All as per srl item No 1.01 here-in-before but for 1.5/2 TR Window Type AC complete all as specified and as directed. |
| 4 | S&F in repair Starting Relay Assembly with Cover & Clip suitable for AC 1.5/ 2.0 Ton capacity, Split type complete all as specified and as directed. |
| 5 | S&F in repair Over load protector for compressor suitable for 1.5 /2.0 TR compressor complete all as specified and directed |
| 6 | S&F in repair thermostat switch for 1.5 /2 TR split/window AC complete all as specified and directed. |
| 7 | S&F in repair starting capacitor suitable for any type ofreciprocating/rotary compressor 80-100 Mfd capacity in metal container all as specified and directed. |
| 8 | S&F in repair starting capacitor suitable for any type ofreciprocating/rotary compressor 120-150 Mfd capacity in metal container all as specified and directed. |
| 9 | S&F in repair running capacitor 36 Mfd capacity in metal container pin type all as specified and directed. |
| 10 | S&F in repair running capacitor 50±4 & 6Mfd capacity in metal container pin type all as specified and directed. |
| 11 | S&F in repair running capacitor 2.5/4/6/10 Mfd capacity in metal bodypin type all as specified and directed. |
| 12 | S&F in repairs Suction/discharge copper pipe line heavy duty up to 1/4\"\" diaand flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed. |
| 13 | S&F in repairs suction/discharge copper pipe line heavy duty 5/8\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. |
| 14 | S&F in repairsPVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with fixed to Wall with necessary Mild Steel Clamps, Screws, etc complete all as specified and directed. |
| 15 | S&F Insulation Sleeve type of Best quality for Copper Tubing for copper Pipe /Foam insulation for copper tubing of size up to 3/8\"\" dia complete all as specified and directed. |
| 16 | S&F in repair new condensing unit of split type AC of 1.5/2.0Window type AC of any capacity complete with condensing copper coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed. |
| 17 | S&F in repair blower motor of 1.5/2 TR split AC (indoor unit) /Window AC any type as per OEM complete all as specified and directed. |
| 18 | S&F in repairnew condenser motor of 1.5/2 TR split AC (outdoor unit) as per OEM incl replacement of bearing bushing etc complete all as specified and directed. |
| 19 | S&F in repair new swing motor of 1.5/2 TR split AC (indoor unit) as per OEM complete all as specified and directed. |
| 20 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 typein required quantity complete all as specified and directed. |
| 21 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134/R410/R-32 typein required quantity complete all as specified and directed. |
| 22 | S&F in repair ofsuction/discharge valve size up to size 3/8\" complete all as specified and directed . |
| 23 | S&F in repairs ofair filter made out of Nylon suitable for 1.5/2 TRcapacity split AC of any Make and model complete all as specified and directed. |
| 24 | S&F in repairs front grillfor window AC of 1.5 TR /2.0 TR of existing make complete all as specified and directed. |
| 25 | M&L for fault finding and pressure leak testing of Split Type Air Conditioners of 1.5 TR / 2.0 TR capacity using dry nitrogen gas to detect leakage in the refrigeration circuit, including pressurising the system and checking all joints, coils and refrigerant pipes, repairing detected leaks by suitable welding/brazing of cooling unit and/or refrigerant pipes, re-pressurising and re-testing after repair to ensure leak-proof system, evacuation, refrigerant charging to required level, testing, trial run, and providing all labour, transportation, tools, plants, gases and consumables required at site, complete all as specified and as directed. |
| 26 | M&L for carrying out fault-finding and pressure leak testing of 1.5 TR / 2.0 TR Window Type air conditioners using dry nitrogen gas to detect leakage in the refrigeration circuit, including pressurising the system and checking the cooling unit and refrigerant pipes, repairing detected leaks by suitable welding or brazing, re-pressurising and re-testing after repair to ensure leak-proof system, evacuation and refrigerant gas charging to the required level, testing and trial run, and providing all labour, transportation, tools, plants, gases and consumables required at site, complete all as specified and as directed. |
| 27 | M&L for carrying out fault-finding and testing of PCBs of 1.5 TR / 2.0 TR Split or Window air conditioners and refrigerators/deep freezers of any capacity, including diagnosis, removal and refixing of PCB if required, rectification of faults, replacement of minor defective electronic components, making good all connections and refixing at existing position, testing and commissioning, complete all as specified and as directed. |
| 28 | S&F in repair new PCB (printed circuit board) along with new cordless remote control, display/visual indicator (IR receiver/display plate) and all necessary connected wiring of indoor unit of Split Type/Window Type air conditioner of 1.5 TR capacity, including fixing in position, making all electrical connections, testing and commissioning, complete all as specified and as directed. |
| 29 | \"All as per srl item No 1.26 here-in-beforebut for 2.0 TR capacity Split AC/Window AC |
| 30 | S&F in repair sealed reciprocating type compressor with accumulator, suitable for Split Type Air Conditioner of capacity 1.5 TR, including removal of old/burnt compressor and installation of new compressor as per manufacturer’s instructions, providing and fixing refrigerant piping connections with necessary brazing, hand shut-off valves, relays and electrical connections, replacement of filter drier/strainer, rubber pads, nuts, bolts and all accessories, including pressure testing, evacuation, charging of refrigerant, testing and trial run, complete all as specified and as directed by Engineer-in-Charge.NOTE:(1) Dismantling and re-installation of outdoor unit, copper tubing, drain pipe, insulation, etc. shall be deemed included in the quoted unit rate.(2) Refrigerant gas, compressor oil, pressure testing and evacuation shall be deemed included in the quoted unit rate.(3) Replaced compressor shall be produced to JE/EIC before disposal.(4) User/occupant’s signature on complaint slip shall be mandatory before payment. |
| 31 | All as per item No 1.29but Reciprocating Type Compressor for 2.0 TR capacity Split Type AC |
| 32 | All as per item No 1.29but Reciprocating Type Compressor for 1.5 TR capacity Window Type AC |
| 33 | All as per item No 1.29but Reciprocating Type Compressor for 2.0 TR capacity Window Type AC |
| 34 | S&F in repairs Bottom tray of 1.5/2.0 TR capacity of Window Type AC made out of 14 SWG mild steel sheet including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 35 | S&Fin repair Condenser fan blade suitable for 1.5/2 TR capacity Split type Air Conditioner complete all as specified and as directed. |
| 36 | S&Fin repair Roller runner, suitable for1.5/2.0 TRcapacity Split type Air Conditioner complete all as specified and as directed. |
| 37 | S&F in repair powder coated metallic stand (02 nos) for fixing outdoor units of Split Type ACs of 1.5/2.0 TR capacity complete all as specified and directed. |
| 38 | S&F in repair Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed. |
| 39 | S&F in repair power contactor 2 pole/3 pole, coil voltage 230Volts of capacity 25 Amps Complete all as specified and directed. |
| 40 | S&F in repair timer single phase analogue type 230 volts complete all as specified and directed. |
| 41 | S&F in repair remote control hand setcompatible with 1.5/2.0 TR capacity split AC and window type Acs, of any make or capacity including testing for proper functioning of AC complete all as specified and as directed. |
| 42 | S&F in repair Selector Switchsuitable for ACs, any make as per site requirement, of capacity 1.5/2.0 TR, Split/Window type complete all as specified and as directed. |
| 43 | M&L for fault finding and testing of auto circuit plate, 220 V, 50 Hz, suitable for Split Type/Window Type air conditioners of any make and of 1.0 TR / 1.5 TR / 2.0 TR capacity, and rectifying the fault by replacing defective minor electronic components such as capacitor, resistor, varistor, IC, relay, etc., including taking down/removal and refixing of the auto circuit plate, making good all electrical connections, testing and commissioning, complete all as specified and as directed. |
| 44 | Taking out, dismantling, and shifting of existing 1.0 TR / 1.5 TR / 2.0 TR Split Type air conditioner of any make, including indoor and outdoor units along with existing MS stand, and re-installation at a new location. Work includes fixing indoor and outdoor units on the old MS stand, providing connection of copper refrigerant pipes using leak-proof joints including necessary brazing, proper insulation of copper pipes, installation and connection of voltage stabiliser, making electrical connections between indoor unit, outdoor unit, stabiliser and power point, provision of additional flexible copper conductor cable as required, testing, trial run and commissioning, complete as specified and directed.NOTE :- (1) The quoted rate shall be deemed to include dismantling, shifting, transportation, making holes in walls, refixing, additional electrical cable, drain pipe, insulation, brazing, pressure testing, evacuation, topping up of refrigerant gas, tools and plants, and all incidental works necessary to make the air conditioner fully functional at the new location.(2) Existing copper refrigerant pipes shall be reused. If any pipe is damaged during dismantling, the replacement shall be measured and paid separately under the respective BOQ item for copper tubing. |
| 45 | Taking out, dismantling and shifting of existing Window Type air conditioner of 1.0 TR / 1.5 TR / 2.0 TR capacity, of any make, shifting to a new location and re-installation as per site requirement, including fixing in position, installation and connection of existing voltage stabiliser, making electrical connections of air conditioner to stabiliser and further to power point, including provision of additional flexible copper conductor cable as required, providing 15 Amp top plug, testing, trial run and commissioning, complete all as specified and as directed.NOTE:- (1) The quoted rate shall be deemed to include cost of dismantling, shifting and transportation, additional electrical cable, drain pipe, minor accessories, refixing, testing and topping up of refrigerant gas, tools and plants, and all incidental works necessary to make the air conditioner fully functional at the new location.(2) Cutting of opening in brick walls, if required, shall be measured and paid separately. |
| 46 | M&L for cutting openings through brick walls for the fixing of Window type Air Conditioner of any capacity, including providing and fixing necessary wooden framework not less than 2\" × 2\" thick as per AC model, fair finishing of side walls with cement mortar (1:6), applying three coats of whitewash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer, cleaning and stacking of bricks, and removal of surplus serviceable bricks, hard-core, and debris from the site, complete all as specified and as directed.NOTE:(1) The size and design of the wooden framework shall match the AC model and is deemed included in the unit rate.(2) Removal, stacking, and disposal of surplus bricks, hard-core, and debris from the site are included in the quoted unit rate.(3) Fair finishing, whitewashing, and painting of wooden surfaces are deemed included in the quoted unit rate. |
| 47 | FLAMEPROOF AC |
| 48 | M&L for servicing, inspection, and fault finding of Flameproof Air Conditioners up to 1.50 TR capacity, including replacement of defective parts such as temperature meter, relay, trip coil, etc., setting the temperature meter to the desired level with autocut, and testing to ensure smooth and proper operation, complete all as specified and as directed.NOTE:(a) All consumables, minor accessories, and replacement parts required for proper servicing are deemed included in the quoted unit rate.(b) Testing and commissioning after replacement of parts and setting of temperature meter are included in the quoted unit rate.(c) Any dismantling and reinstallation of panels or components required for servicing are included in the quoted unit rate. |
| 49 | VERTICAL/TOWER AC |
| 50 | M&L for servicing of Vertical type 3-phase Air Conditioner of any make/capacity, including cleaning of condenser coil fins with mild detergent, cleaning of indoor unit, descaling of condenser coil, taking down the outdoor unit and refixing it at the existing location or any other location, and replacement of insulation of suction and discharge lines, complete all as specified and as directed.NOTE:(a) Removal and reinstallation of the outdoor unit are deemed included in the quoted unit rate.(b) All cleaning materials, detergents, and consumables required for servicing are included in the quoted unit rate.(c) Testing of the AC after servicing to ensure proper operation is included in the quoted unit rate. |
| 51 | M&L for servicing, inspection, and fault finding of Tower Air Conditioners of 7.5 TR capacity, including replacement of defective parts such as thermostat, relays, IC, fuse, resistor, capacitor, safety valve, etc., including testing to ensure smooth and proper operation, complete all as specified and as directed.NOTE:(a) All consumables, minor accessories, and replacement parts required for proper servicing are deemed included in the quoted unit rate.(b) Testing and commissioning after replacement of parts are included in the quoted unit rate.(c) Any dismantling and reinstallation of panels or components required for servicing are included in the quoted unit rate.(d) Both Item No 2.01 & 2.02 shall not be measured for a single AC. |
| 52 | REFRIGERATOR |
| 53 | Dismantling of defective refrigerator of any make and capacity, including shifting/transportation to and from an authorised workshop, thorough checking of all accessories and components, carrying out necessary repairs, reassembling after repair/replacement of defective accessories / components, and testing complete, all as specified and as directed by the Engineer-in-Charge.NOTE:(1) Major parts required for repair of the refrigerator shall be measured and paid for separately under the respective “Supply only” items. However, the cost of all petty spares, minor accessories, consumables, gases, oils, fasteners, etc., required for satisfactory completion of the work shall be deemed to be included in the quoted unit rate. Transportation for shifting the refrigerator to the workshop and back shall be arranged by the contractor at his own cost. |
| 54 | S&F in repairs Thermostatic defrost type Switch suitable for refrigerator of any description complete all as specified and as directed. |
| 55 | Supply and fixing in repair of sealed unit compressor suitable for refrigerator of capacity 120 to 240 litres, including removal of defective compressor, brazing of copper pipes, thorough cleaning/flushing of the refrigerant system, evacuation, charging of refrigerant and compressor oil, replacement of foundation rubber bushes, nuts, bolts and other necessary petty materials, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 56 | Supply and fixing in repair sealed unit compressor suitable for refrigerator of capacity 250 to 320 litres, including removal of defective compressor, brazing of copper pipes, thorough cleaning/flushing of the refrigerant system, evacuation, charging of refrigerant and compressor oil, replacement of foundation rubber bushes, nuts, bolts and other necessary petty materials, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 57 | Material and labour for thorough cleaning/flushing of the refrigerant (gas) system of refrigerator of capacity 120 to 170 litres with suitable approved chemical, including sealing of leakages in the system by brazing, replacement of filter-drier/strainer, providing and fixing new copper capillary (if required), evacuation, charging of refrigerant with anti-moisture substance, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 58 | Material and labour for thorough cleaning/flushing of the refrigerant (gas) system of refrigerator of capacity 286 / 310 / 315 litres with suitable approved chemical, including sealing of leakages in the system by brazing, replacement of filter-drier/strainer, providing and fixing new copper capillary (if required), evacuation, charging of refrigerant with anti-moisture substance, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 59 | S&F in repairs PTC Relay with overload protection suitable for refrigerator of any capacity complete all as specified and directed |
| 60 | S&F in repairs PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types. |
| 61 | S&Fin repairs PCBtimer for refrigerator, any capacity required as per site complete all as specified and directed |
| 62 | S&F in repairs Condenser coil for refrigerator, any capacity complete all as specified and directed |
| 63 | DESERT COOLER |
| 64 | S&F in repair Fan Leaf (Blade), of approved quality suitable for Desert Cooler of any Make and size complete all as specified and as directed. |
| 65 | S&F in repair Front Grill Double Partition type of 20 SWG, best quality (as approved) of suitable size for Desert Cooler, duly spray painted/powder coated including necessary Electric Connection to all Accessories as required complete all as specified and as directed. |
| 66 | S&F in repair Motor Kit suitable 1/7 HP, 180 Watt, 3 speed for Desert Cooler, Copper wounded completeand One Set of Lugs for mounting body complete all as specified and as directed. |
| 67 | S&F in repair Plastic PVC Distributor suitable for Desert Cooler heavy duty 15mm with Elbow, Tee, etc. fixed with Bolts, Nut & Washers complete all as specified and as directed. |
| 68 | S&F in repair Plastic PVC Pipe, 15mm bore suitable for Desert Cooler, heavy duty complete all as specified anddirected. |
| 69 | S&F in repair Running Capacitor 2.5/4/6 mfd, suitable for Fan Motor of Desert Cooler complete all as specified and directed. |
| 70 | S&F in repairSelector Switch suitable for Desert Cooler of any Make and size complete all as specified and as directed. |
| 71 | S&F in repair Submersible Water Pump suitable for Desert Cooler complete all as specified and as directed. |
| 72 | S&F in repairs Mild Steel Desert Cooler Body of 22 SWG Powder Coated with 03 Nos Side Shutters of size 3ft x 2ft x 2ft minimum size, with provision for Noise Pollution Controlcomplete all as specified and as directed. |
| 73 | Material and labour for taking out fan motor from desert cooler of any size and make, 230 volts, 50 Hz, including dismantling, removal of burnt winding, rewinding the motor with super-enamelled copper winding wire of suitable gauge, providing and inserting superior quality insulating materials, slot insulation and sleeves, reassembly, varnishing and proper drying/baking after varnishing, replacement of shaft, gun-metal bushes and rubber bushes for blower motor, refixing in position, testing on load, complete all as specified and as directed by the Engineer-in-Charge. |
| 74 | Supply and fixing in repair of mild steel stand for supporting fan motor of desert cooler, fabricated from suitable size mild steel sections, including cutting, welding, grinding, drilling, providing necessary clamps/bolts, and painting with one coat of red oxide zinc-chromate primer and two coats of approved synthetic enamel paint, complete all as specified and as directed by the Engineer-in-Charge. |
| 75 | Supply and fixing in repair of approved quality heavy-duty wood wool pads suitable for desert cooler, fixed on three inside sides of cooler body, including cutting to size, providing necessary supports/clips and making good, complete all as specified and as directed by the Engineer-in-Charge.NOTE:Replacement of wood wool pads on three sides of one desert cooler shall be measured and paid as one unit. |
| 76 | Material and labour for preparing old painted surfaces of desert cooler body by de-scaling, scraping, wire-brushing, rubbing down and cleaning, including removal of loose rust/paint, and applying one coat of approved synthetic enamel paint by spray gun on outer surfaces of body and tank, and painting inside of tank with one coat of approved black bituminous paint, complete all as specified and as directed by the Engineer-in-Charge. |
| 77 | WATER COOLER |
| 78 | S&F in repair Fan Motor with copper winding suitable for water cooler 40/80 Litre complete with Blades complete all as specified and as directed. |
| 79 | S&F in repair Fan Motor with copper winding suitable for water cooler 120/120 Litre complete with Blades complete all as specified and as directed. |
| 80 | S&F in repair Fan Motor with copper winding suitable for water cooler 150/150 Litre complete with Blades complete all as specified and as directed. |
| 81 | S&F in repair Capacitor of any size and make suitable for compressor of Water Cooler 40/120/150 Litre capacity complete all as specified and as directed. |
| 82 | S&F in repair Self Closing Tap Brass Chromium plated 15mm bore, suitable for Water Cooler of any capacity complete all as specified and as directed. |
| 83 | Supply and fixing in repair of sealed unit compressor suitable for water cooler of 40/80 litre capacity, including removal of defective compressor, brazing of copper pipes, thorough cleaning/flushing of the refrigerant system, replacement of strainer/filter-drier and capillary, evacuation, charging of refrigerant and compressor oil, providing and fixing rubber pads for foundation, nuts, bolts and other necessary petty materials, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 84 | All as per item No 4.06but compressor unit for 120/150 litre capacity water cooler |
| 85 | Material and labour for thorough cleaning/flushing of the refrigerant (gas) system of water cooler of 40/80 litre per hour cooling capacity with suitable approved chemical, including detection and sealing of leakages in the system by brazing, replacement of filter-drier/strainer, providing and fixing new copper capillary (if required), evacuation, charging of refrigerant with anti-moisture substance, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 86 | Material and labour for thorough cleaning/flushing of the refrigerant (gas) system of water cooler of 120/150 litre per hour cooling capacity with suitable approved chemical, including detection and sealing of leakages in the system by brazing, replacement of filter-drier/strainer, providing and fixing new copper capillary (if required), evacuation, charging of refrigerant with anti-moisture substance, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 87 | Supply and fixing in repair of thermostat, including plastic regulating knob, matching the existing make/type, suitable for water cooler of cooling capacity 40 / 80 / 120 / 150 litres per hour, including removal of defective thermostat, making necessary electrical connections, setting and testing for proper operation, complete all as specified and as directed by the Engineer-in-Charge. |
| 88 | S&F in repair Relay for water cooler type suitable for water cooler storage cooling capacity 40/80/120/150litres/hrs complete all as specified and directed |
| 89 | S&F in repair Over load protector for compressor suitable for water cooler of capacity 40/80 /120/150 Litres complete all as specified and directed |
| 90 | DEEP FREEZER |
| 91 | Supply and fixing in repair of sealed unit compressor suitable for deep freezer of 400 / 500 litre capacity, including removal of defective compressor, brazing of copper pipes, thorough cleaning/flushing of the refrigerant system, replacement of filter-drier/strainer (if required), evacuation, charging of refrigerant and compressor oil, providing and fixing foundation rubber bushes, nuts, bolts and other necessary petty materials, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 92 | Material and labour for thorough cleaning/flushing of the refrigerant (gas) system of deep freezer with suitable approved chemical, including detection and sealing of leakages in the system by brazing, replacement of filter-drier/strainer, providing and fixing new copper capillary (if required), evacuation, charging of refrigerant with anti-moisture substance, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 93 | Supply and fixing in repair of fan motor suitable for deep freezer of any type, of 400 / 500 litre capacity, including removal of defective motor, providing and making necessary electrical and mechanical connections, replacement of minor mounting hardware if required, and testing on completion, complete all as specified and as directed by the Engineer-in-Charge. |
| 94 | S&F in repair Relay for deep freezer of any size/capacity complete all as specified and directed |
| 95 | S&F in repair Overload Protector for compressor of deep freezer of any size/capacity complete all as specified and directed |
| 96 | S&F in repair Thermostat for deep freezer complete al as specified and directed |
| 97 | VOLTAGE STABILIZER |
| 98 | Supply, installation, testing and commissioning of 5 KVA single-phase automatic voltage stabiliser, naturally air-cooled, designed for input voltage variation 160 V to 270 V and regulated output voltage 230 V ±2.5%, including removal of existing stabiliser, all necessary connections, mounting, fuses, and accessories, complete as specified and directed. |
| 99 | MISC ITEMS |
| 100 | Supplying, assembling and fixing in repairs on wall, Modular MCB protected Power Unit comprising of following accessories :-(i) Powder Coated Steel terminal box, 06 module - 01 No(ii) Modular Cover Plate with Frame, 06 Module - 01 No(iii) 16 Amps 3 Pin Modular Socket, 02 module - 01 No(iv) 16 Amps Plug Top - 01 No(v) 25 Amps Motor Starter, 02 Module - 01 No(vi) 25 Amps, Single pole Mini MCB, 10kA - 01 No (MAKE: HAVELLS, MODEL: DHDUCDP0253016-25 or similar item in other approved makes) |
| 101 | Supplying, assembling and fixing modular AC power unit comprising of 01 No 16 Amps socket and 01 No 32 Amps SP MCB, 3 modules along with 1.2 mm thick GI metallic flush box, cover plate and frame duly concealed in wall incl taking out existing unsv power unit complete all as specified and directed.NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame. |
| 102 | S&F in repair 32 Amps modular motor starter with cover plate & frame, 2 modules along with 1.2mm thick GI metallic flush box duly concealed in wall complete all as specified and directed.NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box along with starter. |
| 103 | S&F in repair Plug Top, 3 Pin, 5/6 Amp complete all as specified and as directed. |
| 104 | S&F in repair Plug Top, 3 Pin, 15/16 Amp complete all as specified and as directed. |
| 105 | S&F in repair PVC Round Flexible 3 Core Copper Connection Lead of size 2.50 Sqmm with plug complete all as specified and as directed. |
| 106 | S&F in repair PVC Round Flexible 3 Core Copper Connection Lead of size 4.00 Sqmm with plug complete all as specified and as directed. |
| 107 | S&F in repair MCB 32 Amp, Single Pole, 220 Volt, 50 Hz, 10 kA with Thimbles, etc complete all as specified and as directed. |
| 108 | S&F in repair MCB 20 Amp, Single Pole, 220 Volt, 50 Hz, 10 kA with Thimbles, etc complete all as specified and as directed. |
| 109 | S&F in repair 20 Amp metal socket with earth for AC box complete all as specified and as directed. |
| 110 | S&F in repair 20 Amp metal plug with earth for AC box complete all as specified and as directed. |
| 111 | S&F in repair 20 Amp AC box with metal plug and socket without MCB complete all as specified and as directed. |
| 112 | GENERAL NOTES FOR ALL ITEMS:(1) All works for repair of ACs and other connected refrigeration equipment shall be carried out by experienced and qualified refrigeration mechanics. The contractor shall submit necessary documents regarding qualification and experience to the Engineer-in-Charge before commencement of works.(2) Defective spares required to restore ACs, Refrigerators, Water Coolers, and Deep Freezers to satisfactory working condition shall be measured and paid separately under relevant items.(3) Major spares have been considered in the BOQ. The quoted rate is deemed to include consumables, minor spares, nuts, bolts, etc., and no extra claim shall be admissible during execution of work.(4) Make of spares and accessories shall be as per OEM or as approved in writing by the GE.(5) All complaints must be attended to on the same day. If a complaint remains unattended the next working day, a penalty of Rs 100 per day shall be levied on the contractor.(6) Faulty items replaced must be produced to the concerned JE before taking them on credit. If not produced, a recovery of 2% shall be charged against the quoted rates.(7) After completion of each complaint, a copy of the user/occupant’s signature shall be obtained and deposited with the concerned JE. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail