| 1 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | (a)20 mm for mini sheds |
| 3 | (b) 25 mm for mini sheds |
| 4 | Dismentling and re-fixing of 20/25 mm Dia sizes of steel conduit along with accessoriesin surface/recess including painting in case of surface conduit, or cutting the wall andmaking good the same in case of recessed conduit as required. |
| 5 | Supplying and drawing following sizes of FRLS/FRHR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | (a) 3 x 1.5 sq. mm |
| 7 | (b) 4 x 1.5 sq. mm |
| 8 | (c) 5x1.5 sqmm |
| 9 | (D) 3x2.5 sqmm |
| 10 | 6x2.5 sqmm |
| 11 | 3x4 sqmm |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distributionboard, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator) (a) 2 + 4 way/ 6 way , Double door |
| 13 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.(a) Single pole |
| 14 | (b) Single pole and neutral |
| 15 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete withconnections, testing and commissioning etc. as required. |
| 16 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. |
| 17 | Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 amps switch |
| 18 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recesswith suitable size of phenolic laminated sheet cover in front including painting etc asrequired.(a)150 mm X 150 mm X 60 mm deep |
| 19 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) onsurface or in recess with suitable size of phenolic laminated sheet cover in frontincluding providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano typeswitch, connection, painting etc. as required. |
| 20 | 11 Supplying, installation, Testing & Commissioning of 20 watt LED surface mounted Battenlight of following body material and construction as per IS : 10322 with driver(Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surgeprotection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(StandardDeviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housingsuch that LEDjunction temperature shall not rise above 90°C). Powder coated die cast /ExtrudedaluminiumBody (Thickness > 1.20 mm) |
| 21 | Supplying and fixing of following sizes of steel conduit along with accessories insurface/recess including painting in case of surface conduit, or cutting the wall andmaking good the same in case of recessed conduit as required. (a) 40 mm |
| 22 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc.as required. |
| 23 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumenefficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of 45 watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP- 66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 24 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracketfor mounting of fluorescent / HPMV / HPSV street light fitting on pole including bendingthe pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, boltsand washer, painting the flat iron with primer and finish paint etc. as required. |
| 25 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 26 | Providing and fixing 25 mm X 5 mm G.l. strip in 40 mm dia G.l. pipe from earth electrodeincluding connection with G.l. nut, bolt, spring, washer excavation and re-fillinq etc. asrequired. |
| 27 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc.as required. |
| 28 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single corecable in surface/ recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS/HFFR PVC insulated copper conductor single core cableetc. as required.(a) Group c |
| 29 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. asrequired.(A)Group C |
| 30 | Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FRLS/HFFR PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 31 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 32 | (c)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 33 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 34 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distributionboard, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator) (a) 2 + 6way/ 8 way , Double door |
| 35 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/lsolator)(a) 4 way (4 + 12), Double door |
| 36 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. |
| 37 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existingMCB DB complete with connections, testing and commissioning etc. as required.(A) 25 A |
| 38 | Supplying and fixing 63 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 39 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement and wateringpipe etc. with charcoal/ coke and salt as required. |
| 40 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in15 mm dia G.I. pipe from earth electrode including connection with G.I. thimbleexcavation and re-filling as required. |
| 41 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing asrequired. |
| 42 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modularsocket outlet and 15/16 amps modular switch, connection etc. as required. |
| 43 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body.Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 44 | Supply of 225 mm Exhaust fan complete with all accessories like blade, shutter,capacitor and internal wiring with 2 core flexible wire etc as required . |
| 45 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 46 | LED Down lighter (COB Type) (System lumenefficacy ≥105 < 120 lm/Watt ).Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter(Round/ square/ Rectangular) COB Type of following body material and construction asper IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C,internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should bebelow 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximumpower consumption should not more than the specified rating and Fixture shall beconfirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required forLED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminiumhousing such that LED junction temperature shall not rise above 90°C) Powder coateddie cast /Extruded aluminium Body including trim with Aluminium Reflector 5-7 watt |
| 47 | 8-10watt |
| 48 | 18 watt |
| 49 | Supplying of aluminium conductor PVC insulated, PVC sheathed/ XLPE insulated innersheathed steel strip armoured power cable of 1.1 KV grade conforming to IS:7098(Part-I)1988 or latest amended following sizes etc .(a) 4X16 sqmm armoured |
| 50 | Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of1.1 KV grade of following size on wall surface as required.(a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 51 | Supplying and making end termination with brass compression gland and aluminium lugsfor following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cableof 1.1 KV grade as required(a) 4 x 16 sq. mm (28 mm ) |
| 52 | Supplying and fixing following size/ modules, GI box alongwith modular base & coverplate for modular switches in recess etc. as required(a) 2 Module (75mmX75mm) |
| 53 | Supplying and fixing 25A modular AC motor statrer on the existing modular plate &switch box including connections but excluding modular plate etc. as required. |
| 54 | Supplying and fixing 3 pin 25A modular socket outlet in PVC box with modular plate &cover ncluding connections etc. as required. |
| 55 | Supplying and fixing suitable size GI box with modular plate and cover in front on surfaceor in recess, including providing and fixing 2 nos. 3 pin 5/6 A moduler socket outlet and 2nos. 5/6A moduler switch, connections etc. as reqired. (for light plugs to be used in nonresidential buildings). |
| 56 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I.tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate includingholes etc. complete as required. |
| 57 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any othermetallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 58 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall forlightning conductor complete as required.(For horizontal run) |
| 59 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall forlightning conductor complete as required.(For vertical run) |
| 60 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long,with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 61 | Supplying of CU conductor PVC insulated, PVC sheathed/ XLPE insulated inner sheathedsteel strip armoured power cable of 1.1 KV grade conforming to IS:7098(Part-I) 1988 orlatest amended following sizes etc .(a) 2x1.5 sqmm armoured |
| 62 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting basecomplete with all connection etc. as required |
| 63 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 64 | Supplying, installation, testing & commissioning of manualcall boxes of MS construction in surface/recess with stainless steel chain & hammerassembly complete with glass and push button etc. as required. |
| 65 | Supplying, installation, testing & commissioning of manualcall box of ABS type in surface/recess with stainless steelchain & hammer assembly complete with glass and pushbutton etc. as required. |
| 66 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required |
| 67 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable foroperation with amplifier i/c line matching transformer etc.complete as required |
| 68 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired |
| 69 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 70 | Supplying, installation, testing & commissioning sector panel suitable for followingzones, complete with visual indications for short circuit fault, open circuit fault, firecondition and all other standard facilities as per IS:2189 with mimic diagram for allarea/zone covered, complete with all connections, interconnections as required(a) 4 Zone |
| 71 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2indoor Network Switch having features and specifications etc. as mentioned here under:At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFPPorts with non-blocking architecture by having Switching capacity of min. 168Gbps andpacket forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port,Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP,MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP SnoopingV1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 LoopbackInterface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Portbased, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server,server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port,ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Portnumber, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCPserver, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government ofIndia etc. complete as required.(a) 24 port Layer 2 Non-PoE Network Switch |
| 72 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWGTwisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4pair should be complied as per UL/ETL verification program for compliance withANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominalwith Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameterat –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable |
| 73 | 2 Run of cable |
| 74 | 3 Run of cable |
| 75 | 4 Run of cable |