| 1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2 | 1 or 2 Module (75mmX75mm) |
| 3 | 4 Module (125mmX75mm) |
| 4 | 6 Moudle (200mmX75mm) |
| 5 | 8 Module (125mmX125mm) |
| 6 | 12 Module (200mmX150mm) |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 8 | Group A |
| 9 | Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required |
| 10 | 5/6 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | 15/16 A switch |
| 13 | 6 pin 15/16 A socket outlet |
| 14 | Bell push |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \"C\" curve including connections, painting etc. as required. |
| 17 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 18 | Supplying and fixing brass batten/ angle holder/PVC holder including connection etc. as required. |
| 19 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 21 | Group A |
| 22 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 23 | 20 mm |
| 24 | 25 mm |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 26 | 2X10 sq. mm +1X 6 sq. mm earth wire |
| 27 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 28 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 29 | Supplying and fixing following way, single pole and neutral, sheet steel, with MCB distribution board, 240 V,on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 30 | 12 way, Double door |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 32 | Single pole |
| 33 | Single pole neutral |
| 34 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 35 | 40 A |
| 36 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 37 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 38 | 3x2.5 sq.mm |
| 39 | 3x4 sq.mm |
| 40 | 3x6 sq.mm |
| 41 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm. |
| 42 | Supply, Installation, testing and commissioning of 15 watt (2 Feet), 2000 lm,Batten Light, 220-240 V, 50 Hzcomplete i/c all accessories etc directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips Model blaze line compact Cat No. CCT: CDL or equivalent model of Thorn/Trilux |
| 43 | Supply, Installation, testing and commissioning of pre-wired, wall mounted fancy white light, suitable for installation of LED bulb, 220-240 V, 50 Hzcomplete i/c all accessories but without bulb etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No.Comet wall fancy light B22 or equivalent model of Thorn/Trilux |
| 44 | Supply, Installation, testing and commissioning of 12 watt, ceiling circular light for domestic grade, surge protection upto 3 kV & wide voltage protection 160-360 V, 50 Hzcomplete i/c all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make philips, Cat No.Full Glow 12W, WW/NW/CDL or equivalent model of Thorn/Trilux |
| 45 | Supply, Installation, testing and commissioning of 10 watt, LED bulkhead pressure die cast housing with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications., 220-240 V, 50 Hz complete including all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips, Model Endura LED Bulk head, Cat No. WT202W LED10S CW PSUS3 PC or equivalent model of Thorn/Trilux |
| 46 | Supplying and fixing DP sheet steel enclosure on surface/ recess complete etc. as required |