Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | B/R Portion: -Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete removal of debris outside MOD land complete all as specified and as directed. |
| 2 | Demolition of stone slabs and tiles of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete all as specified and as directed. |
| 3 | Taking down cement plaster of any description on brick walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, etc. complete removal of debris outside MOD land (including all necessary scaffolding, lifting arrangement up to 12 mtr height) complete all as specified and as directed. |
| 4 | Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed. |
| 5 | Dismantling or Demolition loose concrete and Material and labour for Gunniting to existing RCC Chajja, facia, parapet, beams, landings and similar RCC members after removing all loose concrete and preparations of surface, application of derusting chemical such as Dr Fixit Rust Remover or equivalent, priming reinforcement bars with a coat of zinc primer of coating not less than 40 micron, provision of bonding agent with bonding material like Dr Fixit bonding agent and repair to external RCC structure with slurry light and steel/ply form work and shortcrete concrete of mixed (1:3:1) (one part of cement, three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thick including plastering 10 mm thick in CM mortar (1:3) (all priming and bonding epoxy based paint shall be of Dr Fixit epoxy zinc primer or equivalent) etc complete all as specified and as directed.Note: - The rates include for necessary formwork, scaffolding and lifting arrangement up to 12 mtr height. |
| 6 | Removing existing treatment from roof surfaces such as tiling, tarfelt, fungus, moss, dust etc., cleaning the surface of all foreign material by wire brushing and dusting and racking out RCC slab complete all as specified and removing the debris outside defence land and all as directed. |
| 7 | PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping, benching, including weathering, slightly rounded or chamfered angles and including necessary form workcomplete all as specified and as directed. |
| 8 | PCC 25mm thick (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) in sub base for floor tiles complete all as specified and as directed by Engineer-in-Charge. |
| 9 | PCC 75mm thick (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in sub base complete all as specified and as directed by Engineer-in-Charge. |
| 10 | PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 11 | Rendering 5mm thick on fair faces of concrete surface of ceiling in cement mortar (1:3), surface finished even and smooth surface without using extra cement complete all as specified and as directed. |
| 12 | Rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar (1:6) surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 13 | Rendering 15mm thick in cement mortar (1:4) on fair faces of brick surface finished even and fair including water proofing compound all as specified (including all necessary scaffolding, lifting arrangement up to 12 mtr height) and all as directed. |
| 14 | Non-Skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Glazed Ceramic tiles 300 x 450 x 7mm thick on vertical surface as in skirting, dado set and jointed with neat cement slurry and pointed in white or coloured cement to match with the surface overand 10 mm thick screed in cement mortar (1:4) complete all as specified and as directed. |
| 16 | Coloured chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey pigment cement and pigment etc and screed bed or bedding layer of mortar 20mm thick (1:4) for laying floor finishes complete all as specified and as directed. |
| 17 | Preparing of new plastered surface of ceiling and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Preparing of new plastered surface of wall and applying wall care putty and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Preparation of new plastered surface and applying two coats of premium acrylic smooth exterior emulsion of approved colour with Silicon additive and Colour stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr (undiluted)/10 sq mtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer\"s instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. (Including all necessary scaffolding, lifting arrangement up to 12 mtr height). |
| 20 | Complete removal of existing treatment and preparation of ceiling and applying two coats ofdistemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Complete removal of existing treatment and preparation of surface and applying wall care putty on old surface of walls and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge. |
| 22 | Complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint and applying two coats of premium acrylic smooth exterior emulsion of approved colour with Silicon additive and Colour stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr (undiluted)/10 sq mtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer\"s instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. (Including all necessary scaffolding lifting arrangement up to 12 mtr height). |
| 23 | Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturer\"s method statement by Berger HS Rapairo (or equivalent) along with HS Latex Plus (or equivalent) and cement in mixing ratio of (1:4) where ever required complete all as specified and as directed. |
| 24 | Home Shield PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied, waterproofing membrane that is highly elastic and UV resistant. ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties. (i) UV resistant, prevent yellowing and weathering. (ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates. (iv) Tensile Strength >10 N/Sqmm with GeoTextile fleece. (v) Solar Reflective Index (SRI) more then 109-111ASTM E1980-11. System: First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer(or equivalent), Coverage : 0.2Kg/Sqm (with 50% dilution of water), Reinforcement: Geotextile 40 gsm, Second coat: Home shield roofkoat (or equivalent), Consumption: 0.5 Kg/Sqm, Third coat: HS PU roofkoat (or equivalent), Consumption : 0.8 Kg/Sqm. System buildup -1.5Kg/Sqm with geotextile of 40gsm complete all as specified and as directed. |
| 25 | 600mm x 450mm bevelled edge mirror of selected quality, glass 5mm thick, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 26 | Providing and laying crystal glass mosaic tile random 3 colour of any size as approved by GE and thickness 3.5 to 5mm on floor/vertical surfaces on swimming pool of approved manufacturer and specified shade like Orient Blue / Dark Blue / new blue or any pattern etc. laid in approved pattern on 5mm average thick bed of adhesive mortar of Polymer modified cementitious adhesive in conjuction with polymer modified liquid equivalent product of etc mixed in required porportion as specified by manufacturer including filling / sealing of joints 2-3 mm thick between the tiles with epoxy grout with matching colour pigment to make it water tight and finished neat complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Curtain Rods, mild steel, chromium plated with fixing brackets, stops, side finnels etc complete with all fittings complete all as specified and as directed. |
| 28 | Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 29 | 25mm thick PVC Swimming pool overflow modular covers heavy duty anti slip surface in any colour complete all as specified and as directed by Engineer-in-Charge. |
| 30 | 20mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down 15mm steel tubing complete all as specified and as directed. |
| 31 | Vitreous china wash down water closet (Pedestal Pattern) \"P\" or \"S\" trap (excluding flushing cistern and flush pipe) including PVC seat cover white closed pattern with recessed bottom and connection to drain or outgoing pipe and flushing pipe complete all as specified and as directed. |
| 32 | Vitreous China Wall hang wash hand basins including 32mm bore PTMT Waste coupling, waste pipe and PVC connection pipe of 15mm x 450mm long complete all as specified and as directed.Makes: - Cera, Cat Part No : S2040121 or equivalent in makes as mentioned in Group - I of Appx \"F\". |
| 33 | 10 litres capacity PVC low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 450mm long etc complete all as specified and as directed. |
| 34 | 15mm bore chromium plated cast copper alloy bib taps fancy type with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and all as directed by Engineer-in-Charge. |
| 35 | 15mm bore chromium plated Pillar tap Swan neckwith Swinging Spout of brass, glossy finish completeall as specified and as directed. |
| 36 | 15mm bore Angle/ Stop cock of chromium plated, glossy finish completeall as specified and as directed. |
| 37 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm bore pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and as directed. |
| 38 | Tubular towel rail 20mm dia \"D\" type 60cm long between flanges chromium plated complete all as specified and as directed. |
| 39 | Rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of existing water tank, including 20mm Ball Valves, 20mm Tank nipple complete all as specified and as directed by Engineer-in-Charge. |
| 40 | 25mm outer dia CPVC gate valves complete all as specified and all as directed by Engineer-in-Charge. |
| 41 | 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls/ floor etc complete all as specified and as directed. |
| 42 | 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls/ floor etc complete all as specified and as directed. |
| 43 | PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete all as specified and as directed. |
| 44 | PVC (SWR) Bends / Tee / Y 110mm dia any radiuswith access door complete all as specified and as directed. |
| 45 | PVC (SWR) Bends / Tee / Y 75 mm dia any radius with access door complete all as specified and as directed. |
| 46 | E/M Portion: -Cleaning of sludge receiving chamber, screen channel, MBBR unit, Tube settler unit and chlorine mixing contact tank (Civ unit) of the plant at Uri Line STP of capacity 175 KLD complete all as specified and as directed.Note: - Tube settler is required to be removed before cleaning of STP and stack properly. After cleaning is completed, tube settler is to be re-fixed in its original position.The quoted rate shall be deemed to include the same. |
| 47 | Cleaning of sludge dry bed, drain line (Civ unit) and surrounding area of plant i.e. excavated grass / weeds/ hard cement concrete/ stone, debris, excess soil etc. at Uri Line STP of capacity 175 KLD complete all as specified and as directed.Notes: - (i) The rate shall be deemed to be include the cost of removing the grass, weeds, debris, excess soil etc to a distance not less than 2000m and keeping the excavated surface clean and levelled.(ii) If there is any damage to the existing services like HT/LT UG cable, telephone wire, pipe line and sewage line etc, the same shall be repaired by the contractor immediately and quoted rates shall be deemed to include the same. |
| 48 | Scrubbing of outer wall surfaces with wire brush of receiving chamber, screening chamber, MBBR chamber, sludge settler and chlorine mixing tank of capacity 0.5 MLD to 1.2 MLD of plant and preparing the surfaces of wall, chajjas, facias, faces of columns, beam including all metal/ pipe line surfaces etc and applying two coats of weather proof exterior emulsion paint over a coat of 1mm thick wall care putty complete all as specified and as directed.Notes: - The quoted rates shall also be deemed to include: -(i) Removal of scrapped material deposited at plinth protection to a distance upto 50 mtr from plant.(ii) All types of safety equipments and tools required at site. |
| 49 | Filling of PVC bio pac floating media of MBBR unit of the sewage treatment plant of size 22mm x 13mm, thickness 1.5 mm complete all as specified and as directed. |
| 50 | Supply and fixing in replacement of automatic star delta starter, three phase of suitable size of motor 15/20 HP with over current relay control system, single phase preventor, Phase reversal protection, Phase unbalance protection, Auto restart (with variable 30 sec to 5 min on delay) and power on and pump on indication complete all as specified and as directed. |
| 51 | Supply and fixing in replacement of automatic star delta starter, three phase of suitable size of motor 25/30 HP with over current relay control system, single phase preventor, Phase reversal protection, Phase unbalance protection, Auto restart (with variable 30 sec to 5 min on delay) and power on and pump on indication complete all as specified and as directed. |
| 52 | Supply and fixing in replacement of single phase preventor, 230 Volts, 50 cycles etc complete all as specified and as directed. |
| 53 | Material and Labour for taking out 2.5-7.5 HP non clog submersible pump set from sewage sump, disconnecting pipes, pump and transporting to workshop for repair, cutting of burnt winding/ cleaning of stator for rewinding with super enamelled copper wire of existing size, providing with insulating materials, flame proof/ water proof laminated insulated strips, cotton tape, varnishing complete and shifting back to site and lowering and assembling in the existing position, connecting and testing complete all as specified and as directed. |
| 54 | Material and labour for replacement of thrust bearing of non clog submersible motor of capacity 2.5 HP to 7.5 HP complete all as specified and as directed. |
| 55 | Material and labour for replacement of gun metal bushes for non clog submersible motor of capacity 2.5 HP to 7.5 HP complete all as specified and as directed. |
| 56 | Material and labour for replacement of Impellers for non clog submersible pump of capacity 2.5 HP to 7.5 HP complete all as specified and as directed. |
| 57 | Material and labour for replacement of Bowl bush for non clog submersible pump of capacity 2.5 HP to 7.5 HP complete all as specified and as directed. |
| 58 | Material and labour for replacement of Neck ring for non clog submersible pump of capacity 2.5 HP to 7.5 HP complete all as specified and as directed. |
| 59 | Material and labour for replacement of Seal guide sleeve for non clog submersible motor of capacity 2.5 HP to 7.5 HP complete all as specified and as directed. |
| 60 | Material and labour for dismantling and de-coupling air blower pump of capacity up to 20 HP from existing foundation with electric motor, repair/ overhaulding, replacement/ adjustment of the following spares: -(a) Adjustment of safety valve.(b) Replacement of spring assy.(c) Re-metalling/ turning of pump shaft. (d) Replacement of oil ENKLO 320, oil seal, bearing,filter.(e) Replacement of pressure gauge.(f) Replacement of Air filter/cleaner.(g) Any minor spares required and re-assembling the pump, testing including painting complete all as specified and as directed.Note: - The cost of transportation to and from workshop is deemed to be included in the quoted rate. |
| 61 | Material and labour for disconnecting air blower motor of capacity up to 20 HP from air blower pump and transporting to workshop for repair, cutting of burnt winding/ cleaning of stator for rewinding with super enamelled copper wire of existing size, providing with insulating materials, flame proof/ water proof laminated insulated strips, cotton tape, varnishing complete and shifting back to site, lowering and assembling in the existing position, connecting and testing complete all as specified and as directed. |
| 62 | Supply and fixing in replacement of V Fan belt for blower compressure as per existing makecomplete all as specified and as directed. |
| 63 | Repair and maintenance of existing sludge duct of size 450mm x 600mm by providing 50-80 mm thick PCC (1:3:6), type C-1 (using 20 mm graded crushed stone aggregates) in existing drain wall duly finished with 15 mm thick cement mortar (1:4) complete all as specified and as directed. |
| 64 | Material and labour for framed work such as gateway (any size with opening and closing) of dry bed duct, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand, ladder and similar work conforming to Fe-290, Gde-E-165 including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and as directed. |
| 65 | Carry out water (Raw and treated) from all STP plants and testing for bacterial, chemical and biological analysis of sewage water treated water from Govt approved lab for following parameters and submission of test reports all as directed: -(a) PH(b) Chemical Oxygen demand/COD(c) Biological Oxygen Demand/BOD(d) Total Suspended solids(e) Oil and Grease(f) TKN(g) Total Coliform(h) Organism MPN(j) Dissolved OxygenNote: - Water testing shall be carried out twice in the period of contract and empty collection bottle will be arranged by the contractor. |
| 66 | Supply and fixing sewage non-clog submersible pump set of capacity 7.5 HP, 4\"\" Delivery 25 Meters Head and fixing of nuts, bolts, washer complete all as specified and as directed. |
| 67 | Material and labour in repair for complete earthing with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to GI strip 25 x 4mm by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1, precast RCC cover slab using reinforcement with XPM weighing not less than 4.00 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40mm dia medium grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed. |
| 68 | Supply of culture for bacteria production complete all as specified and as directed. |
| 69 | Supply and filling of Alum at Swimming Pool complete all as specified and as directed. |
| 70 | Material and labour for providing PMM (Polymer modified cementitious mortar) as under: -(i) Dry substrate surface and make free of debris and dust.(ii) Apply Epoxy bond coat on the sound substrate using approved spray machine and ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above, apply 15 mm thick PMM (Polymer modified cementitious mortar).Note: - Application of PMM shall be preferably be in coat of appx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed within 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer complete all as specified and as directed.Note: - Complete treatment to be carried out by authorised applicator of the manufacturer. |
| 71 | Supply and fixing in replacement carbon steel butterfly valve, screwed both ends for iron pipe of 150 mm bore complete all as specified and as directed. |
| 72 | Supply and fixing DI/ MS specials of pipe upto 200 mm dia bore such as bends, tees, collars, tail pieces etc conforming to latest IS complete all as specified and as directed. |
| 73 | Supply and fixing in replacement of MCCB 200 Amps, 4 pole, 415 V, 3 phase, 50 Hz of breaking capacity 36 KA with adjustable thermal and adjustable magnetic setting complete all as specified and as directed. |
| 74 | Supply and fixing in replacement of MCCB 160 Amps, 4 pole, 415 V, 3 phase, 50 Hz of breaking capacity 36 KA with adjustable thermal and adjustable magnetic setting complete all as specified and as directed. |
| 75 | Supply and fixing in replacement of MCCB 100 Amps, 4 pole, 415 V, 3 phase, 50 Hz of breaking capacity 36 KA with adjustable thermal and adjustable magnetic setting complete all as specified and as directed. |
| 76 | Supply and fixing in replacement of MCCB 63 Amps, 4 pole, 415 V, 3 phase, 50 Hz of breaking capacity 36 KA with adjustable thermal and adjustable magnetic setting complete all as specified and as directed. |
| 77 | Supply and fixing in replacement 1100 volts grade, heavy duty submersible flat cable, PVC insulated and PVC sheathed 10 Sqmm 3 core with stranded copper conductor, suitable for submersible motors and pumps and making connection complete all as specified and as directed. |
| 78 | Repair / Maint / service to swimming pool filteration plant complete with cleaning of underground sump by removing dirt and mud, repairs of unserviceable spare parts fitting valves, filter media, PVC strainer, Pressure gauge, Butterfly valve, air vent pipe complete with cleaning internally including taking out all filter media outside and kept separately each media at site for reuse, preparing external services of filter media and make the surface smooth and applying two coats of synthetic enamel paint and a coat of red oxide primer compete with suction and discharge pipe and relaying all filter media in proper layer duly washed and tested on full load complete all as specified and as directed.Note: - Spare shall be measured and paid separately. |
| 79 | Supply and fixing in replacement water pressure gauge 10 KG 100 mm dia complete with 3/8 inch brass sampling cock complete all as specified and as directed. |
| 80 | Material and labour in replacement of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm bore complete all as specified and as directed. |
| 81 | Supply and fixing double deck type PP strainer of size 3/8 inch or 1/2 inch complete all as specified and as directed. |
| 82 | Supply and fixing in replacement suction sweeper complete assembly along with pump motor for swimming pool (pool cleaner) 36 inch long complete with wheels, PVC core nylon brush 36 inch NRV complete all as specified and all as directed. |
| 83 | Supply and fixing in replacement suction flexible rubber hose pipe 80 mm dia braided type green colour conforming to ISI complete with suitable size mild steel clamp complete all as specified and as directed. |
| 84 | Supply and fixing superior quality copper sulphate complete all as specified and as directed. |
| 85 | Supply and fixing PVC insulation patch roll for submersible cable connection complete all as specified and as directed. |
| 86 | Disconnecting and taking out of existing submersible pump set from borewell capacity 5 to 15 HP alongwith their column pipe and submersible cable from bore well from any depth complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Lowering the submersible pump set complete with motor and pump capacity 5 to 15 HP in bore well and connecting to existing system complete all as specified and as directed by Engineer-in-Charge. |
| 88 | Material and labour for strip opening complete submersible pumping set having capacity 5 to 15 HP any stage/ discharge and dismantling all spare parts by opening studs complete with machine/ lathe work/ grinding/ polishing and fitting of all spare parts and re-assembling/ installation in position after necessary repair/ repairs of unserviceable/ defective spare parts complete all as specified and as directed.Note: - Spare parts shall be measured and paid separately under respective items as under: - |
| 89 | Supply and fixing cast iron stage bowl complete all as specified and as directed. |
| 90 | Supply and fixing cast iron suction discharge chamber complete all as specified and as directed. |
| 91 | Supply and fixing stainless steel neck ring complete all as specified and as directed. |
| 92 | Supply and fixing stainless steel bowl bush complete all as specified and as directed. |
| 93 | Supply and fixing stainless steel coupling sleeves complete all as specified and as directed. |
| 94 | Supply and fixing cast iron impeller with key complete all as specified and as directed. |
| 95 | Supply and fixing body studs fully threaded complete all as specified and as directed. |
| 96 | Supply and fixing stainless steel pump shaft complete all as specified and as directed. |
| 97 | Supply and fixing stainless steel pump shaft coupling with key complete all as specified and as directed. |
| 98 | Supply and fixing cast iron NRV with NRV seat and cone complete all as specified and as directed. |
| 99 | Supply and fixing stainless steel sleeves for bowl complete all as specified and as directed. |
| 100 | Supply and fixing rubber bush complete all as specified and as directed. |
| 101 | Supply and fixing strainer for pump complete all as specified and as directed. |
| 102 | Supply and fixing in replacement of chlorine test kit with coloured sample complete with all testing fillaments and OT solution in rexin finish wooden box complete all as specified and as directed. |
| 103 | Material for chlorine gas cylinder for cleaning and disinfection of swimming pool water containing algaecide and coagulant with arrangement for controlled release of active ingredients in water and head suspensor complete all as specified and as directed. |
| 104 | Material and labour for pool cleaner solution liquid type for cleaning swimming pool and bring it to clear state complete all as specified and as directed. |
| 105 | Dismantling and taking down electric motor of dozing system and shifting in workshop for repair and rewinding with super enamelled copper winding wire of same gauge and nos of turns complete with insulated material i.e. varnish, cotton tape, bamboo strips, emory paper and drying including replacement of unserviceable spare parts complete all as specified and as directed. (Spare parts shall be measured and paid separately under respective items). |
| 106 | Supply only motor seal |
| 107 | Supply only motor bearing |
| 108 | Supply only motor fan blade |
| 109 | Supply only rotor shaft |
| 110 | Supply only coupling |
| 111 | Dismantling and taking down dozing pumping set and shifting in workshop for repair/ maintenance/ overhauling and reassembly after necessary repair complete with and including replacement of unserviceable/ defective spare parts and tested on load at site complete all as specified and as directed. (Spare parts shall be measured and paid separately under respective items). |
| 112 | Supply only Agitator assembly |
| 113 | Supply only Agitator bearing |
| 114 | Supply only Agitator Shaft with stainless steel blade duty FRP coated |
| 115 | Supply only PE tubing 5/8\"\" (8 mtr) |
| 116 | Supply only solenoid motor |
| 117 | Supply only electronic controlled circuit plate |
| 118 | Supply only injection check valve (NRV) |
| 119 | Taking down old unserviceable flood lights and Material and labour for new LED flood light fittings of 150 watt, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility including make proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge. |
| 120 | 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge. |
| 121 | 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 16 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge. |
| 122 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ofsize 95 Sqmm 3½ core complete all as specified and as directed. |
| 123 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in loose/ soft soil and getting out for underground cable/ erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge. |
| 124 | Supply, laying and fixing of DWC HDPE pipe for protection for power cable (orange in colour) of size 75 mm dia complete with joint fittings and including cutting, jointing and clamping complete all as specified and as directed. |
| 125 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. |
| 126 | Removal of excavated material not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge. |
| 127 | Material and labour for Altoch GP packing of 45 Kg in drum complete all as specified and as directed. |
| 128 | Supply and fixing in replacement of submersible cable 10 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI complete all as specified and directed by Engineer-in-Charge. |
| 129 | Material and labour for repair and cleaning including filling of cracks and water proofing to underground well sump of any capacity internally at appx depth ofby using water treatment chemical/ bleaching powder/ Sodium hypochloride chemical including cleaning internally entire wall surface, removing deposited particular, scrubbing complete wall surface and applying coat treatment water chemical on complete wall and drain out the water after disconnecting all rising/ distrbution sluice valves complete with painting to mild steel/ Steel railing/ rising/ distribution/ wash out CI pipe with different colour complete all as specified and as directed and writing date of tank cleaning. |
| 130 | Material and labour for replacement of CI sluice valve PN 1.6 with iron wheel head of size 150 mm bore with stainless steel spindle both end flanged complete with nut, bolts, washer and rubber gaskit 3 mm thick conforming to ISI 14846/2000 complete all as specified and as directed. |
| 131 | Supply and laying MS Black pipe P/E ISI marked conforming to IS 1239 PART -1 (2004) of 150 mm dia bore medium grade (\"B\" Class) with flanged end joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint, nuts and bolts and gaskets and testing complete, duly painted with two coats of bituminous paint externally complete all as specified and as directed by Engineer-in-Charge. |
| 132 | Supply and laying MS Black pipe P/E ISI marked conforming to IS 1239 PART - 1 (2004) of 50 mm dia bore medium grade (\"B\" Class) with flanged end joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding and testing complete, duly painted with two coats of bituminous paint externally complete all as specified and as directed by Engineer-in-Charge. |
| 133 | Supply and fixing Swimming pool outlet Nozzle of size 50mm complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy