| 1 | Surface dressing n.exc 15 cm deepgetting out in any type of soil complete all as specified and as directed. |
| 2 | Excavating over areas, not exceeding 1.5m deep and getting out in any type of soil complete all as specified and as directed. |
| 3 | Excavating over areas, exc 1.5m and not exceeding 3m deep and getting out in any type of soil complete all as specified and as directed. |
| 4 | Excavating over areas, exc 3.0m and not exceeding 4.5m deep and getting out in any type of soil complete all as specified and as directed. |
| 5 | M&L PCC 1:3:6 as in type C2 (40mm graded aggregate) Cement concrete in foundations, filling and mass concrete complete all as specified and as directed. |
| 6 | Use and waste for Formwork of Square, rectangular or polygonal to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface complete all as specified and as directed |
| 7 | Use and waste for Formwork of Square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface complete all as specified and as directed. |
| 8 | Use and waste for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams for fair finished surface complete all as specified and as directed |
| 9 | Use and waste for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surface complete all as specified and directed. |
| 10 | Use and waste for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surface complete all as specified and directed. |
| 11 | Material and labour for use and waste of timbering as planking and Shuttering for excavations in over areaand including use and waste if ranking shores and fixing and removing including wales, struts, open poling boards, etc if tightly driven close butt-jointed sheeting is ordered including packing cavities behind the sheeting with suitable material complete all as specified and as directed.Note : The item shall be executed as per IS 3764 : 1992 (Excavation work – Code of safety) |
| 12 | M & L for Reinforced cement concrete Grade M-30(design Mix ) using 20mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 13 | M & L for Reinforced cement concrete Grade M-30(design Mix ) using 20mm graded stone aggregate) as incolumns, pillars, piers, posts and struts complete all as specified and directed |
| 14 | M&L for Reinforced cement concrete Grade M-30(design Mix ) using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed |
| 15 | M&L for Reinforced cement concrete Grade M-30(design Mix ) using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the lik complete all as specified and as directed. |
| 16 | S&Fmildsteel TMT bars10 mmdia andover ,cut to length , benttoshaperequired, includingcranking , bendingspirallyforcolumnshookingfor columnshookingends and bindingwith and includingmildsteelwire ( annealed )not less than 0.9mmdia or securing with clips complete all as specified and as directed. |
| 17 | S&Fmildsteel TMT bars 6 to 8mm dia ,cut to length , benttoshaperequired, includingcranking , bendingspirallyforcolumnshookingfor columnshookingends and bindingwith and includingmildsteelwire ( annealed )not less than 0.9mmdia or securing with clips complete all as specified and as directed. |
| 18 | Returingfillingin includingspreadinglevellingwater ing and wellramming layers not exc 25cm complete all as specified and as directed. |
| 19 | Removingexcavatedmaterialexc 500 mtrs and n.exc 1000 m deposition where directed at level n exc 1.5 above the starting point complete all as specified and as directed. |
| 20 | M&L for pre cast cement concrete solid block masonry exc 10 cm in width with minimum compressive strength of 50kg/sqcm using PCC 1:3:6 type C-1(using 20mm graded aggregate) set in CM 1:6 complete all as specified and as directed. |
| 21 | M&L for rendering 15mm thick on fair faces ofbrick or concrete surfaces in cement mortar 1:6, including finishing even and smooth without using extra cement complete all as specified and as directed. |
| 22 | M&L two coats of cement base paints primer onwall including necessary preparation of newly plastered surfaces complete all as specified and as directed. |
| 23 | M&L for 100 mm thick Broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 24 | M&L for 100mm thick PCC 1:2:4, type B-1 (20mm graded aggregate) as in sub base complete all as specified and as directed. |
| 25 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 25 mm thick Sand filling under floors complete all as specified and as directed. |
| 26 | Supply, Install, testing of modular, circular bolted panel Zinc alum steel water tank of net capacity 125 KL of standard nearest size available, dia 5.00m, height 6.94 mtr approx. to dtore potable water with 150mm free board from top and 150 mm dead water level from bottom. The outer shell shall be made of colour Bond Zincalume alloy coated, composition of coating shall be AI - 55%, Zinc- 42.5% and Si - 2.5%, High tensile steel sheet shall be made up of not less than 0.8 mm as per manufacture recommendations for tank body. Theroof of tank shall be made of colour bonded Zincalume alloy coated with High tensile steel sheet duly supported by hot dipped galvanised metal tube trusses fully welded, length of roof sheet used shall be such that minium number of end laps for entire roof are used, where ever required the end lap shall not be less than 300 mm and cener of over lap shall be at truss center line, Roof sheet thickness shall not be less than 0.47 mm with Grade G550. The load bearing capacity of roof shall be 100Kg/Sqm Make of shee Tata Blue Scope/JSW. contd...26.01 & 26.02 |
| 27 | Tank liner shall be of 800 GSM, S10EN B 7631 or equivalent , minimum breaking strength / 2500 N/5 cm WARP, 2000 N/5 Cm weft, tear strength warp 270N/ 5cm , weft 270 N/5 cm. Adhesion 90 N/5 cm, temp resistance - 30 degree C to 70 degree C. The liner shall be adequately protected using 4mm thick geo textile material at the bottom and at a critical points. The tank shall be provided with all standard accessories like out let, over flow, wall mounted drain nozzles, heavy duty caged ladder from outside platform and hand rail, nylon rpe ladder with Aluminium steps inside the tank & Top heavy duty lockable hinged access (600mm X 600mm )= 01 NO, Tank hold down brackets, MS nozzles, flanges as per BS 10 grade D complete all as specified and as directed. |
| 28 | Notes :- (i) Tank shall be designed for seismic Zone V. (ii) All nozzle shall be extended clear of tank. The vermin proof vent with stainless steel revolving turbine type extractor fan shall be provided to remove condensation and preventing corrosion to roof.(iii) The corrosion protection to tank shall be done by providing sacrificial anode of Magnesium of suitable size.(iv)The Modular tank shall carry warranty for 5 years for water storage part & workmanship which include 24 months installation defect liability. (v) rates are inclusive of 01 No inlet, 01 No outlet, 01 No washout valve of suitable capacity complete all as specified and as directed. |
| 29 | Supply , Laying, fixing and testing3- layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass theaded polypropylene random fittings ofsize of outer dia110 mm ,(including bend, elbow, reducer, socket & Tee etc) laidin trenches complete all as specified and as directed. |
| 30 | Supply, Laying, fixing and testing3- layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass theaded polypropylene random fittings ofsize of outer dia 75 mm (including bend, elbow, reducer, socket & Tee etc) laid in trenches complete all as specified and as directed. |
| 31 | Supply, Laying, fixing and testing3- layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass theaded polypropylene random fittings ofsize of outer dia 63 mm(including bend, elbow, reducer, socket & Tee etc) laid in trenches complete all as specified and as directed. |
| 32 | Making connection of PP-R distribution branch with PP-R main of by providing and fixing tee including cutting and making fusion joints etc, outer dia size of pipe in 50mm to 75mm complete all as specified and as directed. |
| 33 | S&F forPP-R gate valves (brass insert)outer dia of pipes is 63mm complete all as specified and as directed. |
| 34 | S&F forPP-R gate valves (brass insert)outer dia of pipes is 75mm complete all as specified and as directed. |
| 35 | S&F forPP-R gate valves (brass insert)outer dia of pipes is 110mm complete all as specified and as directed. |
| 36 | S&F forSluice Valves, flanged of class 1.6 PN, 100 mm dia complete all as specified and as directed. |
| 37 | S&F forLEDflood Light 150 watts 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver complete all as specified and as directed. |
| 38 | S&F forSPN 32 Amps , 240 volts, 10KA, \"C\" curve miniature circiuit breaker (MCB)complete all as specified and as directed. |
| 39 | Suppl and laying XLPE insulated, armoured heavy duty electic cable with aliminium conductor, 1100 volts grade, cross-sectional area 10sqmm X 2.0 core complete all as specified and as directed. |