Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of Cable/pipe and getting out in soft loose soil complete all as specified and as directed. |
| 2 | Description all as per item No. 1 above but inHard dense soil |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. |
| 4 | Description allas per Item No- 2 abovebut depth exceeding 1.5 mtr and not exceeding 3 mtr complete for pole foundation |
| 5 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 6 | Material and labourfor PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path and for chain link fencing etc complete all as specified and asdirected. |
| 7 | Material and labour forPCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and as directed. |
| 8 | Material and labour for stone dust for cousioning of UG cable/ at cable trenches /inside substation bulding etc complete all as specified and as directed. |
| 9 | Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm complete all as specified and as directed. |
| 10 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & 14930 (Part-I and II) for protection of underground cable of size 40mm outer dia with all fittings such as clamps, coupler etc. laid in trenches/roads/nallah or fixed along wall/ poles or laid under floor (including cutting floor/road and making to match with existing adjouning surface etc. for cable protectioncomplete all as specified and as directed. NOTE:- Excavatoin and earth work measured and paid separately) |
| 11 | Description allas per item No. 10 above but of size 50mm outer diameter |
| 12 | Description allas per item No. 10 above but of size 63mm outer diameter |
| 13 | Labour for Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.complete all as specified and as directed. |
| 14 | Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty XLPE UG cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanisedsteel wire or tape and overall PVC sheathed6 sqmm2 core with required aluminium cable lugs all as specified and as directed. |
| 15 | Description allas per item No. 14 above but 10sqmm 2 core |
| 16 | Description allas per item No. 14 above but 16sqmm 2 core |
| 17 | Description allas per item No. 14 above but 10sqmm 4 core |
| 18 | Description allas per item No. 14 above but 16sqmm 4 core |
| 19 | Description allas per item No. 14 above but 25sqmm 3.5 core |
| 20 | Description allas per item No. 14 above but 35sqmm 3.5 core |
| 21 | Description allas per item No. 14 above but 50sqmm 3.5 core |
| 22 | Description allas per item No. 14 above but 70sqmm 3.5 core |
| 23 | Description allas per item No. 14 above but 95sqmm 3.5 core (MW LINE TO 512 WORK SHOP) |
| 24 | Description allas per item No. 14 above but 120sqmm 3.5 core(MES IB TO AWWA HOSTEL) |
| 25 | Description allas per item No. 14 above but 185sqmm 3.5 core |
| 26 | Description allas per item No. 14 above but 240 sqmm 3.5 core |
| 27 | Labour for dismantling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and keeping aside for refixing or carrying to store for creditcomplete all as specified and as directed. |
| 28 | Material and labour for steel tubular swaged pole complete with cast ironbase plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted below ground level with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long).complete all as specified and as directed. |
| 29 | Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit all as specified and as directed. |
| 30 | Material and labour cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and as directed. |
| 31 | Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of credit complete all as specified and as directed. |
| 32 | Material and labour for replaceing old ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and as directed. |
| 33 | Labour for dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and as directed. |
| 34 | Material and labour pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified and as directed. |
| 35 | Material and labour shackle type,porcelian vitreouswhite, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm heightand 115 mm dia for 1100 Volts grade complete all as specified and as directed. |
| 36 | Material and labour loop type insulator, porcelian vitreousbrown of size 65x90mm and clearence hole 16mm complete all as specified and as directed. |
| 37 | Material and labour for stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismantling unsv one complete all as specified and as directed.NOTE :- Clamps, loop insulator, earth work, PCC measured separately |
| 38 | Material and labourfor stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismantling taking down unserviceable one complete all as specified and as directed. |
| 39 | Material and labour forcradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismantling taking out unsv cradle guard complete all as specified and as directed. |
| 40 | Suply and fix earth continuity wire using GI wire not less than 4mm dia on pole incl dismantling taking out unsv GI wire complete all as specified and as directed. |
| 41 | Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and as directed. |
| 42 | Material and labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr belo ground level connected to galvanized iron strip of size 32x6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earh work GI pipe 20 mm dia medium grade for watering PCC chamber with PCC cover in cement concreate 1:2:4 Type B1 (20 mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc connected to panel board/ Gen set as indicated including testing complete all as specified and as directed.NOTE :- Earth protection pipe & earthing strip upto and including 7.5 m lenth is deemed included in unit rate quoted by the contractor. |
| 43 | Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-45 met span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and as directed. |
| 44 | Material and labour for restraining of ACSR conductor of any size of 2 wire 35-45 met span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and as directed. |
| 45 | Material and labour for restraining of GI Cradle guard hexagonal/rectangular of any size 35-45 met span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&Pcomplete all as specified and as directed. |
| 46 | Material and labour for restraining of GI earth wire of any size 35-45 met span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&Pcomplete all as specified and as directed. |
| 47 | Cutting/Trimming of tree branches arround 3.00 met distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc fron poles complete all as specified and as directed. |
| 48 | Cutting/Trimming of tree branches arround 3.00 met distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc fron poles complete all as specified and as directed. |
| 49 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core,complete all as specified and as directed. |
| 50 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 25-50 sqmm, 3.5 core,complete all as specified and as directed. |
| 51 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 70-150 sqmm, 3.5core,complete all as specified and as directed. |
| 52 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 185-300 sqmm, 3.5 core, complete all as specified and as directed. |
| 53 | Material and labour heat shrink straight through joint out door type LT 1100 volts grade 10-16 sqmm, 4 core, complete all as specified and as directed. |
| 54 | Material and labour heat shrink straight through joint outdoor type LT 1100 volts grade 25-50 sqmm, 3.5 core, complete all as specified and as directed. |
| 55 | Material and labour Heat shrink straight through joint outdoor type LT 1100 volts grade 70-150 sqmm, 3.5 core, complete all as specified and as directed. |
| 56 | Material and labour Heat shrink straight through joint outdoor type LT 1100 volts grade 185-300 sqmm, 3.5 core, complete all as specified and as directed. |
| 57 | Material and labour for Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms, clamps, stay clamps etc with two coats of aluminium paint after surface preparation complete all as specified and as directed. |
| 58 | Material and labour for Numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in site with white paint on black back ground complete all as specified and as directed. |
| 59 | Material and labour GI tubing light grade 40mm bore,on pole /wall with necessary clamps, nuts, bolts and washers/under road cross ISI marked, for cable protection including taking out old pipes complete all as specified and as directed. |
| 60 | Material and labour GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection including taking out old pipes complete all as specified and as directed. |
| 61 | Material and labour GI tubing light grade 80mm bore,on pole /wall with necessary clamps, nuts, bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection including taking out old pipes complete all as specified and as directed. |
| 62 | Material and labour GI tubing light grade 100mm bore,on pole /wall with necessary clamps, nuts, bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection including taking out old pipes complete all as specified and as directed. |
| 63 | Material and labour for jumper connections of length up to 1.50 met with existing size and guage of ACSR, binding with existing conductors for LT OH lines complete all as specified and as directed. |
| 64 | Material and labour for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size including taking out defective danger boards complete all as specified and as directed. |
| 65 | Material and labour for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 11000 volts, 25 x 20 cm size including taking out old danger boardscomplete all as specified and as directed. |
| 66 | Supply and errect Cast Iron HT/LT cable route indicator round shaped 120 mm dia 8 mm thick duly embossed with MES HT/LT Cable fixed on flat iron 25X3 mm thick 300 mm long and grouted in PCC complete all as specified and as directed. |
| 67 | Material and labour for rigid PVC line spacer, U-shaped, spriral type, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified and as directed. |
| 68 | Material and labour for rigid PVC line spacer, U-shaped, spriral type, suitable for 4 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified and as directed. |
| 69 | Material and labour for aluminium cable lugs of size 50 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point complete all as specified and as directed. NOTE :-To be measured only, fixed at places other than with heat shrink joints |
| 70 | Material and labour for aluminium cable lugs suitable for XLPE cable size 70 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction pointcomplete all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints . |
| 71 | Material and labour for aluminium cable lugs suitable for XLPE cable size 95 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point complete all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints . |
| 72 | Material and labour for aluminium cable lugs suitable for XLPE cable size 120sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point complete all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints . |
| 73 | Material and labour for aluminium cable lugs suitable for XLPE cable size 150 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point complete all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints . |
| 74 | Material and labour for aluminium cable lugs suitable for XLPE cable size 240 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point complete all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints . |
| 75 | Material and labour for aluminium cable lugs suitable for XLPE cable size 300sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point complete all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints . |
| 76 | Material and labour for MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 400 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 77 | Material and labour for replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 350 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 78 | Material and labour for replaceingMCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 79 | Material and labour for replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 80 | Material and labour for replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 160 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 81 | Material and labour for replaceingMCCB, 3 pole, 35 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 200 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 82 | Material and labour for replaceingMCCB, 3 pole, 35 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, withthermal magnetic release, 350 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 83 | Material and labour for replaceing MCCB, 3 pole, 35 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 160 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 84 | Material and labour forreplaceingMCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 125 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 85 | Material and labour for replaceingMCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 100 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 86 | Material and labour for replaceingMCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, 63 amps, incl dismantling taking down unsv one complete all as specified and as directed. |
| 87 | Material and labour for replaceing MCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, withthermal magnetic release, 40 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 88 | Material and labour for replaceing 1100 volts grade heavy dutyflat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathedin service connections from OH conductor to building incl dismantling taking down unserviceable one complete all as specified and as directed. |
| 89 | Description all as item No 88 above but size of cable 6 sqmm |
| 90 | Description all as item No 88 above but size of cable 4 sqmm |
| 91 | Labour for disconnecting LT cable of any size from structure/pole/transformer for finding fault ,material and labour for defect rectification LT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 6 hours of instruction from all as specified and as directed Engr-in-Charge.NOTE:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 6 hours after notification, failing to which Rs 500/- per day complaint will be recovered. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quoted rate all as specified and directed by Engr-in-charge. joint kit will be measured separately in appropriate item in this schedule |
| 92 | Material and labour for replaceing of LT pannelout door type , wether and dust proof indoor type2 mm thickCRCA sheet for outer body double door and 2.00 mm thick CRCA sheet for inner partition walls, independent cabinet with cabinet doors forMCCB\"s, Bus bars, cable trays, metering equipment vertical type, floor mounted, minimum IP-54 protection, suitable grouted to PCCfoundation work with angle iron base frame 50x50x6mm complete with internal wiring, epoxy powder coated and connection of cable ends with suitable size of cable lugs and also provided locking arrangement with the following accessories.and CPRI approved complete all as specified and as directed . NOTE :- DRG to be got approved from the GE before the order is placed (a) Aluminium bus bar chamber capacity 400 Amps 3 Phase 4 wire duly insulated with PVC sleeves (As per colour code) incl complete control wiring with suitable size PVC copper conductor cable.(b) Digital Ammeter with CT and selector switch, 0 to 400 Amps - 01Nos.(c) Digital Volt meter with selector switch , 0 to 400 Volt- 01 Nos. Contd to .....92.01 |
| 93 | Contd from,,...92.00(d) Phase indicator lamps, LED type - 03 Sets.(e) MCCB 250 Amps, 4 Pole 50 KA with adjustable thermal & fixed Magnetic settings - 01 Nos (Incoming).(f)MCCB 100 Amps,3 Pole, 25 KAwith adjustable thermal & fixed Magnetic settings- 01 Nos (Outgoing). (g) MCCB125 Amps, 3 Pole, 16 KAwith adjustable thermal & fixed Magnetic settings - 01 Nos (Outgoing).(h) MCCB63 Amps,3 Pole, 16 KAwith adjustable thermal & fixed Magnetic settings - 03 Nos (Outgoing). |
| 94 | Material and labour for replaceing of LT pannelout door type, wether and dust proof indoor type2 mm thickCRCA sheet for outer body double door and 2.00 mm thick CRCA sheet for inner partition walls, independent cabinet with cabinet doors for MCCB\"s, Bus bars, cable trays, metering equipment vertical type, floor mounted, minimum IP-54 protection, suitable grouted to PCCfoundation work with angle iron base frame 50x50x6mm complete with internal wiring, epoxy powder coated and connection of cable ends with suitable size of cable lugs and also provided locking arrangement with the following accessories and CPRI approved complete all as specified and as directed.NOTE :- DRG to be got approved from the GE before the order is placed (a) Aluminium bus bar chamber capacity 400 Amps 3 Phase 4 wire duly insulated with PVC sleeves (As per colour code) incl complete control wiring with suitable size PVC copper conductor cable.(b) Digital Ammeter with CT and selector switch, 0 to 400 Amps - 01Nos.(c) Digital Volt meter with selector switch , 0 to 400 Volt- 01 Nos.(d) Phase indicator lamps, LED type - 03 Sets. Contd to 93.01 |
| 95 | Contd from,,...93.00(e) MCCB 315 Amps, 4 Pole 50 KA with adjustable thermal & fixed Magnetic settings - 01 Nos (Incoming).(f) MCCB160 Amps,3 Pole, 25 KAwith adjustable thermal & fixed Magnetic settings - 01 Nos (Outgoing).(g) MCCB125 Amps, 3 Pole, 16 KAwith adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing).(h) MCCB63 Amps,3 Pole, 16 KAwith adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing). |
| 96 | Material and labour for replaceing of LT pannelout door type, wether and dust proofout of 3.15 mm thickCRCA sheet for outer body double door and 2.00 mm thick CRCA sheet for inner partition walls, independent cabinet with cabinet doors for MCCB\"s, Bus bars, cable trays,metering equipment vertical type, floor mounted, minimum IP-54 protection, suitable grouted to PCCfoundation work with angle iron base frame 50x50x6mm complete with internal wiring, epoxy powder coated and connection of cable ends with suitable size of cable lugs and also provided locking arrangement with the following accessories and CPRI approved complete all as specified and as directed. NOTE :- DRG to be got approved from the GE before the order is placed (a) Aluminium bus bar chamber capacity 400 Amps 3 Phase 4 wire duly insulated with PVC sleeves (As per colour code) incl complete control wiring with suitable size PVC copper conductor cable.(b) Digital Ammeter with CT and selector switch, 0 to 400 Amps - 01Nos.(c) Digital Volt meter with selector switch , 0 to 400 Volt- 01 Nos.(d) Phase indicator lamps, LED type - 03 Sets. Contd from,,...94.01 |
| 97 | Contd from,,...94.00(e) MCCB 200 Amps, 4 Pole 36 KA with adjustable thermal & fixed Magnetic settings - 01 Nos (Incoming).(f)MCCB100 Amps,3 Pole, 25 KAwith adjustable thermal & fixed Magnetic settings- 02 Nos (Outgoing).(h) MCCB63 Amps,3 Pole, 16 KAwith adjustable thermal & fixed Magnetic settings - 01 Nos (Outgoing). |
| 98 | Material and labour for Replaceing outdoor type Distribution panel box CPRI aprroved and tested, fabricated from ISO certified factory of overall size 750 mm (L) x 400 mm (B) x 1500 mm (H) made with 3.15 mm thick CRCA sheet with hinged door front & Rear for each cabinet powder coated by post office red and bottom black after anti-rust treatment of CRCA sheet. Top cabinet with incoming 3ph & N aluminium busbar of size 40x10mmchamber, Middle cabinet for mounting including MCCB 3 pole 125 amps - 1 No and for 3ph & N distribution aluminium busbar of of size 30x6mm and side cabinet for incoming cable tray.2 Nos earth terminal, door lock for front and rear door with additional external locing arrangement, Door handle for each front & rear door, mounting stand made with ISA 40x6mm and 500mm long leg, duly painted with one coat of black bituminous paint , LT Danger notice board at front and rear. One MCCB of 25 KA, 125 amps, 3 pole between incoming and outgoing busbar as mentioned above and 2 Set of aluminium busbar as mentioned above with size complete all as specified and as directed.Contd to 95.01 |
| 99 | Contd from,,...95.00NOTE :- (i) The FPB shall be errected after dismentling taking out old unserviceable one. (ii) Disconnection of all cables from old FPB and reconnection of all cables to new FPB shall be done and rate shall be inclusive of the quoted rate. (iii) Panel shall be CPRI type tested and to be fabricated in ISO certified panel manufacturing factory (iv) PCC foundation work for panel deemed to be inculiding in quotedrate. |
| 100 | Material and labour for Replaceingoutdoor typeDistribution panel box CPRIapproved and testedwether and dust proof. fabricated from ISO certified factory of overall size 750 mm (L) x 400 mm (B) x 1500 mm (H) made with 3.15 mm thick CRCA sheet with hinged door front & Rear for each cabinet powder coated by post office red and bottom black after anti-rust treatment of CRCA sheet. Top cabinet with incoming 3ph & N aluminium busbar of size 40x10mmchamber, Middle cabinet for mounting including MCCB 3 pole 250 amps - 1 No and for 3ph & N distribution aluminium busbar of of size 30x6mm and side cabinet for incoming cable tray.2 Nos earth terminal, door lock for front and rear door with additional external locing arrangement, Door handle for each front & rear door, mounting stand made with ISA 40x6mm and 500mm long leg, duly painted with one coat of black bituminous paint , LT Danger notice board at front and rear. One MCCB of 25 KA, 250 amps, 3 pole between incoming and outgoing busbar as mentioned above and 2 Set of aluminium busbar as mentioned above with size complete all as specified and as directed. Contd to 96.01 |
| 101 | Contd from,,...96.00NOTE :-(i) The FPB shall be errected after dismentling taking out old unserviceable one. (ii) Disconnection of all cables from old FPB and reconnection of all cables to new FPB shall be done and rate shall be inclusive of the quoted rate. (iii) Panel shall be CPRI type tested and to be fabricated in ISO certified panel manufacturing factory (iv) PCC foundation work for panel deemed to be inculiding in quotedrate . |
| 102 | Material and labour for cleaning of MES Electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalites n.exc 15cm deep (including removing vegetation/shrubs/brush wood/under-growth) and carrying away the rabbish to a distance of n.exc 50 mtr away complete at an intervalof every 30 days for the following installations :-(a) Sarvatra Vihar Sub Stn |
| 103 | Description all as item No 97 but Sub stn No.-01&02 TB-II |
| 104 | Description all as item No 97 but Sub stn No.-03& 04TB-II |
| 105 | Description all as item No 97 but Sub stn of MAP QTR TB-II |
| 106 | Description all as item No 97 but Sub stn No.-01&02 Dunkrik Line |
| 107 | Description all as item No 97 butSub stn No.-03& 04 Dunkrik Line. |
| 108 | Supply and fixin replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protectioncomplete all as specified and as directed.MAKE:- Hensel Cat No.DK 2525 G |
| 109 | Material and labour for replaceing old Unsv 4mm dia Hot Dipped Galvanized Chain Link Fencing with Zinc Coating, including line wires,any type of standards, rails, straining bolts, etc. including provission of binding wire incl dismentling taking down unserviceable one (2.8 Kg per sqm with 2\"x2\" mess of 3 mm wire) complete all as specified and as directed. |
| 110 | Material and labour for replaceing old unsvmild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and welding or connecting with bolts and nuts incl dismentling taking down unsv one complete all as specified and as directed. |
| 111 | Material and labour for replaceing old unsvTMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securingwith clips complete for support of chain link fencing incl dismentling taking down unsv onecomplete all as specified and as directed. |
| 112 | Material and labour for filling and spreading stone aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and 11KV Receiving power stn etc. complete all as specified and as directed. |
| 113 | Supply and fixglow sign boards of size 12\" x 3\"x1\" made out of acrylic sheet of 3 mm thick with letters as directed at various Sub Station holding on 3.5 mtr height stainless steel pipe 32mm, height 3 Mtr, providing lighting / illumination with four tube light set and wiring upto connected point complete as per sample all as specified and as directed .NOTE :- Sample of glow sign board to be got approved by Engr-in-charge/GE before placing the order. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail