| 1 | Dismantling old plasterandraking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 2 | Material and labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, Complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Material and Labour for rendering 15 mm thick incement mortar 1:4, complete all as specified and directed. |
| 4 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as specified and directed. |
| 5 | Material and Labour for finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives New work (Two coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm) complete all as specified and as directed by Engr in charge. |
| 6 | Material and labour for Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (twocoats) over and including water thinnable priming coat with cement primer complete all as specified and directed. |
| 7 | Supply and fix mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters:walk ways, railing, framed work of water tanks and similar work conforming to Fe 290 Gde E-165, Complete all as specified and directed by Engineer-in-Charge. |
| 8 | Dismantling doors, windows and clerestory windows (steel or wood or pvc) shutter Of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead complete all as specified and directed. |
| 9 | Material and labour for Aluminium Powder coating section (minimum thickness of powder coating 50 micron) for door/window / Ventilators / partition etc frames & shutters sliding or openable type including necessary joining cleats,Hinges,tower bolts,handles,mullion glazing clips, rubber packing, anodised aluminium snap beading , screws, sliding track,rolleretc complete of standard sections complete all as specified and directed by Engr-in charge. |
| 10 | Dismantling tile work in floors,wall and roofs laid in cement mortar including stacking material within 50 metres lead for any thickness of tiles complete all as specified and directed |
| 11 | Providing and fixing Ist quality ceramic Antiskid floor tiles conforming to IS: 15622 (thickness not less than 7mm), of approved make & coloursof any size as approved by Engineer-in-Charge, over 20 mm thick bed of cement mortar 1:3and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 12 | Providing and fixing G.I. Pipes 15 mm dia medium grade complete with G.I. fittings and clamps,including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint,complete all as specified and directed |
| 13 | Providing and fixing G.I. Pipes 20 mm dia medium grade complete with G.I. fittings and clamps including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint,complete all as specified and directed |
| 14 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed. |
| 15 | Providing and fixing in repairC.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 15 mm nominal dia complete all as specified and directed. |
| 16 | Providing and fixingin repairC.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 15 mm nominal dia complete all as specified and directed. |
| 17 | Providing and fixingin repairswash basin with C.I. brackets, 15 mm chromium plated brass pillar taps, 32 mm chromium plated brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 550x400 mm with and including 15 mm dia pillar tap fancy type chromium plated complete all as specified and directed. |
| 18 | Providing and fixingin repairs CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge complete all as specified and directed. |
| 19 | Providing and fixingin repairsframeless mirror of superior glass (of approved quality) and approvedmake and shade Rectangular shape1500x450 mmfixed with PVC sheet complete all as specified and directed. |
| 20 | Supply and Fix Rough cast wired glass, 6.4mm thick of area exc 0.75 Sqm and n. exc 1.00 Sqm and glazing clip with oil putty at any height including necessary arrangement complete all as specified and directed. |
| 21 | Painting on oldiron or mild steel surfaces with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade in (two coats) over a coat of approved steel primer complete all as specified and directed. |
| 22 | Providing & fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Fine Fissured (Bevelled Tegular) Edge Tiles 15mm thick of Armstrong Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.6, Light Reflectance >85%, Thermal Conductivity k=0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 pt-6 & 7) in module size of 600 x 600 x16mm, suitable for Green Building application, with Recycled content of 31%. The tile shall be laid on Armstrong Suprafine 32 with 15mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200mm & 600mm cross Tees with a web height of 32mm and a load carrying capacity of 7.5 Kgs/M2 & minimum pull out strength of 100 Kgs. The \"T\" sections have galvanising of 90 grams per M2 and need to be installed with suspension system complete all as specified and directed. The tile & grid system used together should carry a 10 year warranty. NOTE : The work shall be executed through authorised applicator of manufacturer. |
| 23 | Supply, fixing, testing and commissioning of automatic GI rolling shutter of 1mm strip, 7\"6\" width and 11\"3\" height with top cover 0.05 mm GI sheet 25\" long, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete and comprising of motor single phase, 400 Kg capacity, MS Pipe 100 mm dia 5 mm thick, Remote control etc. all as required complete all as specified and directed |
| 24 | Complete removal of existing Roof treatment in any layers including demolition of PCC in roofs unreinforced and disposal of debris to distance exc 250 metre and not exc 500 metre out of MoD land complete all as specified and directed.Note: i) The rates are inclusive of removal for any type old water proofing treatment over to Main RCC slab. ii) All the dismantled debris are required to be removed from HEMRL premises right after demolition so that process of user should not get obstructed. |
| 25 | Material and labour for PCC 1:2:4 (Type B0 using 12.5 mm graded crushed stone aggregate) (40mm thick avg) as in levelling course to match the undulations of roof and in coving, roof kerbs including benching etc including necessary formwork and finished rough surface complete all as specified and directed. |
| 26 | Material and labour for rendering 10 mm thick in cement mortar 1:3 mixed with liquid water proofing compound (ISI marked) of approved make as per manufacturer\"s instructions over RCC roof slab and finished fair and even without using extra cement complete all as specified and directed.(Liquid water proofing compound shall be measured and paid seperately as \"Supply only\".) |
| 27 | Material and labour for preparation of surface to make free from dust particles, ditr etc, Porous concrete surfaces to be primed with Nitoproof WB primer, Providing and applying Fosroc Nitoproof 600 PF of Fosroc chemicalsa single component pitch free polyurethane based coating that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane, It is elastomeric, seamless waterproof membrane applied in 2 coats to achieve DFT 1.5 mm thick having a elongation capacity of over 600%. Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified mortar as per vendor recommendation. Laying 200 gsm non woven geo textile membrane over Nitoproof 600 PF coating with overlap sealed using synthetic rubber adhesive before providing screed concrete, Complete all as specified and directed by Engineer-in-Charge.The material shall achieve following properties: (i) Elongation (ASTM D412) : 600 %, (ii) Specific gravity : 1.50 + 0.1 g/cc, (iii) Solid content : 85% min., (iv) Tensile strength (ASTM D412): 2.5 N/mm2,(v) Crack bridging (ASTM C836) > 2mm Tear resistance (ASTM D624) : 15 kN/m, (vi) Water vapour transmission(ASTM E96) : 0.6 g/m²/hr., (vii) Water permeability @ 5 bar : Nil,(viii) Shore A hardness (ASTM D2240) : 60, (ix) Adhesion in-peel test (ASTM C836) > 50NNote . The work shall be executed thru auth applicator of manufecturer only. Contarctor has to provide manufecturer test certificates for the above mentioned technical parameters and PVs. The conractor has to submit the guarntee for 10 Years against the water proofing treatment. |
| 28 | Supply only integral liquid WPC of approved make complete all as specified and directed |
| 29 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 metre in width as well as 10 sqm on plan including getting out all kinds of soil and disposal of excavated earth upto 50 meter and lift upto 1.5 metre complete all as specified and directed by Engineer-in- Charge. |
| 30 | Material and labour for Hardcore of guage exc 63mm but n.exc 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface, Complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Material and labour for PCC 1:4:8 type D2,using 40mm graded crushed stone aggregate as in sub base complete all as specified and directed. |
| 32 | Providing and laying concrete of M20 grade in position ready mixed or site batched designmix cement concrete for plain cement concrete work, using coarse aggregate and fine aggregate derived from natural sourcesPortland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS 9103 to accelerate/retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge. For the following grades with minimum cement content of 270 kg /cum complete all as specified and directed |
| 33 | Material and labour for forming 20mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `B\" thickness of slab 100mm complete all as specified and directed. |
| 34 | Demolition of brick work/stone masonry/ PCC block masonry built in cement mortar or cement lime mortar including all quoins, pillars, arches etc, but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed. |
| 35 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge |
| 36 | Dismantling of old RCC pipes 150 mm dia including breaking of joints and bed concrete stacking of useful materials near the site within 50 metrelead and disposal of unserviceable materials into municipal dumps complete all as specified and directed. |
| 37 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in any type of soil (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 38 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 type C1 (graded stone aggregate 20 mm nominal size)complete all as specified and directed. |
| 39 | Supply and Fix 10mm Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete all as specified and directed above plinth level . |
| 40 | Material andlabour for centering and shuttering including strutting, propping etc. and removal of form forcolumns, pillars, piers, abutments, posts and strutscomplete all as specified and directed. |
| 41 | Providing and laying in RCC work in 1:1/2:3 tupe A1 using 20mm graded stone aggregate in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, filets, columns, pillars, piers, abutments, posts and struts etc above plinth levelupto floor five level excluding cost of centering shuttering, finishingcomplete all as specified and directed. |
| 42 | Material and Labour for PCC block masonry with solid blocks, exc 10 cm in width and setting CM 1:6 precast cement concrete block of type C-1 with 1:3:6 (using 20 mm graded stone aggregate), Complete all as specified and directed by Engineer-in-Charge. |
| 43 | Material and Labour for Rendering 12mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 using WPC, Complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately) |
| 44 | Material and labour for PCC (1:2:4) Type B1 (using 20mm graded curahed stone aggregate) in coping and bed blocks for angle iron post including necessary formwork/moulds complete all as specified and directed. |
| 45 | Removing excavated material in soft/loose soil exc 250metre & not exc 500metre and depositingwhere directed at a level n. exc 1.50metre above starting point complete all as specified and directed. |
| 46 | Returning filling including spreading, leveling watering and Well ramming in layers n.exc 25 cmthick in soil complete all as specified and directed. |
| 47 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan)including up rooting of rank vegetation, green bush wood trees and saplings of girth up to 30 cms measured at a height of 1.0 m above ground level dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m all kind of soil complete all as specified and directed |
| 48 | Material and labour for random rubble masonry in CM 1:6 with hard stone in superstructure above plinth level and upto floor five levelcomplete all as specified and as directed. |
| 49 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 using type B1 graded stone aggregate 20 mm nominal size complete all as specified and directed. |
| 50 | Extra over for stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified of face beds and joints as specified of random rubble walling, uncoursed or brought upto courses with 20mm deep in granite or trap stone complete all as specified and directed. |
| 51 | Material and labourfor keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:3) complete all as specified and directed. |
| 52 | Supply and Fix 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints as in trenches wall, sweep hole etc complete all as specified and directed. |
| 53 | Material and labour for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, Complete all as specified and as directed by Engineer-in-Charge. |
| 54 | Material andlabour for centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, beam wall, bases of columns, etc. for mass concrete complete all as specified and directed. |
| 55 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 type B1 (using 20 mm graded stone aggregated) complete all as specified and directed. |
| 56 | Material and labour for PCC 1:2:4 type B1 using 20mm graded stone aggregte as in surface channels & drain complete all as specified and directed. |
| 57 | Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 58 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes300 mm dia with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc. complete all as specified and directed. |
| 59 | Taking down copper/aluminimum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets , light fitting etc removing materials to store for keeeping insafe custody of for taking credit(creditfor above items should be made as per conditions separately) and making good disturbed surfaces for walls, floors, etc complete all as specified and directed. |
| 60 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators complete all as specified and directed. |
| 61 | Taking down unserviceable distribution boards of any size with MCBOs/MCBs/MCCBs any type for taking schedule of credit complete all as specified and directed |
| 62 | Group C wiring for light point/Socket point/Fan point/exhaust fan point / call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core multistrand copper conductor FRLS cable drawn into & including concealed PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required (a) One light point controlled by one : one way switch |
| 63 | (b) All as per item No __ but for One 3 pin 5 Amp socket out let controlled by one switch indep board |
| 64 | All as per item No ___ but of 15 Amps point with 4 sqmm cablecomplete all as specified and directed |
| 65 | Supply and fixing in repairs 3/5 Pin 5/6Amodular Socket outlet on existing modular plate & switch boxincluding connections but excluding modular plate etc as required |
| 66 | Supply and fixing in repairs 6 Pin 15/16Asocket outlet, 2 module on the existing modular plate & switch boxincluding connections but excluding modular plate etc as required |
| 67 | Supply and fixing in repairs modular 15/16 Amp switch, 1 module on the existing modular plate & switch box including connections but excluding modular plate etc as required complete all as specified and directed |
| 68 | Supply and fixing in repairs ceilling rose 3 terminal 240 volts, 5 Amps complete all as specified and directed |
| 69 | Supply and fixing in repairs LED tube light fitting 2 X 20W, 4 feet long general purpose industrial compact streak batten suitable for twin LED tube light with integral LED driver, available in single/double side connection options including connecting complete with all accessories internally prewired and provision of flexible three core copper conductor 23/0.0076 upto 1.5 mtr from ceiling rose to fitting all as directed by Engr-in-charge. |
| 70 | Supply and fixing LED Bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed |
| 71 | Supply and fixing in repairs Air circulator fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed |
| 72 | Supplying and fixing in repairs 3 module (100 mm x 75 mm ) size/modules GI box alongiwth modular base & cover plate for modular switches in recess etc as required complete all as specified and directed |
| 73 | Material and labour for sub main wiring using twosingle core 6 sqmm copper conductor,FRLScable drawn through and including PVC non metalic conduit concealed of suitable size,including one run of PVC FRLS insulated copper earth continuity wire of6.0 sqmm and connected to earth dolly including cutting chases for concealed conduitwiring complete all as specified and as directed. Note: 2 run of 6 sqmm ( 01 for phase and 01 for neutral) with 1separate run of 6earth wire and one run of PVC conduit will be measured as one unit.complete all as specified and directed. |
| 74 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required complete all as specified and directed (But without MCB/RCCB/Isolator) |
| 75 | Supply and fixing 5 to 32 Amps rating , 240V, 10 KA \"C\" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioining etc as required complete all as specified and directed |
| 76 | Supplying and fixing 63A rating, four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required complete all as specified and directed |
| 77 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including taking down old unserviceable earthing complete all as specified and directed (for 02 Nos TPN DB) |
| 78 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 16.0 sq mm 4 core complete all as specified and directed |
| 79 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LTunder ground cable and getting out all type of earth stata complete all as specified and as directed |
| 80 | Supply and lay in trench reinforced precast concrete Class LV, Type I,flat,size 250 mm x 150mm x 40mm LT cable protection complete all as specified and directed by the Engr-in-charge |
| 81 | Material and labour for crushed Sandin cable trenches as cushioning to cables including spreading and punning down all complete all as specified and directed. Note : Punned thickness shall only be measured and paid |
| 82 | Cutting Bituminous road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri complete all as specified and directed |
| 83 | Material and labour for GI tube, 50 mm dia light grade with necessary fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection all as specified for the following size of pipe complete all specified and directed.NOTE :-(Excavation and earth work where required shall be measured separately.MSClamps for fixing on wall / pole , etc are included in the quoted rate). |
| 84 | Supply install, testing and commissioning of Energy ratingBEE 5 star Split Air condioning capacity of 2 TR with indoor and outdoor unit having comprising of the following :-(a) Multi stranded copper conductor wire 3 core 4 Sqmm with copper lugs upto 10.0 mtrs (b) Incoming and outgoing quality copper pipe with foam insulation duly whiled taped of each size upto 10.0 mtrs (c) Having 2 nos of bracket duly powder coated with anchor fasteners, nut, washers set 01 (d) Key features (i) Multi adjustable mode (ii) High ambient cooling (iii) Super dry (iv)Turbo cooling (v) ECO friendly Refrigerant R-32/ R-410A (vii) 100% Copper (viii) Sleep mode (ix) Wide Voltage range operation(x) The ISEER value of Air conditioner shall be 4.5 (minimum) (xi) Cordless remote-01 No.Note: 1. Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on wall of building roof top shall deemed to be included in quoted rate. 2. Rate for Scafolding/Ladder/Tools and plants required to install Air conditioner i.e for making of holes to wall, drilling, making good distrubed surfaces and matching with the existing colour shall deemed to be included in quoted rate. 3. Outdoor unit should be kept above the level of indoor unit for installation of ground floor ACs outdoor should be on wall surfaces and for First floor ACs should be on parapet wall of Roof top of the building with out extra cost.4. The MES Number be painted on indoor and Outdoorunit with navy blue colour letters of size not less than 15 mm height. Drain pipe from indoor unit to plinth protection of Outside the building. 5. The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and make good to the existing surface with putty and paint complete all as specified and directed. |
| 85 | Material and labour for Voltage stabilizer for automatic operation, single phase naturally air cooled type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 with accuracy + 1% and speed of correction 50 Volts per second and of capacity 5 KVA complete all a specified and directed |
| 86 | Material and labour for sub main wiring using twosingle core 4 sqmm copper conductor,FRLScable drawn through and including PVC non metalic rigid conduit of suitable size,including one run of PVC FRLS insulated copper earth continuity wire of6.0 sqmm and connected to earth dolly including cutting chases for concealed conduitwiring complete all as specified and as directed. Note: 2 run of 4 sqmm ( 01 for phase and 01 for neutral) with 1separate run of 6earth wire and one run of PVC conduit will be measured as one unit.complete all as specified and directed. |
| 87 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutal bus bar, earth bar, din bar, internconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 88 | Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps \"C\" curve 230 Volts and repturing capacity 10 KA complete all as specified and directed by Engr-in-Charge. |