| 1 | sch \"A\" Part-I (B/R-I)Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil completeall as specified and directed. |
| 2 | Excavating over areas n.exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm all complete all as specified and directed |
| 4 | Removal excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point completeall as specified and directed |
| 5 | M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) as in foundations, filling and mass-concrete completeall as specified and directed |
| 6 | M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 completeall as specified and directed |
| 7 | M&L for precast reinforced cement concrete in baffle walls or manhole covers type B1 1:2:4 (using 20mm graded stone aggregates) including necessary metal lathing or TMT bar having weight not less than 2% by volume of RCC inside and use and waste of formwork kept in position in brick masonry and set in cement mortar 1:3 as directed completeall as specified and directed |
| 8 | M&L for 15mm thick rendering in CM 1:4 for internal / external wall surfaces and finishing surface even and smooth without using extra cement completeall as specified and directed |
| 9 | M&L provinding cement concrete (1:2:4) B-1 as in copings / bearing course over brick walls etc and like complete all as specified & directed. |
| 10 | M & L for 50mm thick cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in floor of septic tank finishing surface even and smooth without using extra cement etc complete all as specified and directed . |
| 11 | S&F cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc of weight exc 5 Kg in each complete all as specified and directed |
| 12 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed |
| 13 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of shythetic enamel paint over a coat of red oxide primer completeall as specified and directed |
| 14 | M&L for preparation of new or previously untreated plastrered surfaces and applying two coats of cement based paint completeall as specified and directed |
| 15 | M&L provinding cement concrete (1:2:4) B-1 as in copings / bearing course over brick walls etc and like complete all as specified. |
| 16 | M&L for cement concrete 1:3:6 type C2 (40mm graded stone aggregates) as in surface channels and drains complete |
| 17 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete |
| 18 | S&F in repairs PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 19 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out |
| 20 | M&L for 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with colars laid in trenches and jointed as specified complete |
| 21 | M&L for concrete bed to drain pipes for 150mm dia RCC NP-2 pipes using PCC 1:4:8 type D-2 (using 40mm graded aggregates) including forming cradles complete all as specified and directed. |
| 22 | M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm dia of pipe complete |
| 23 | S & F in repair powder coated aluminium anodized door shutter of size 100x44x2 mm thick , vertical styles of shutters made with sections 84x44x2 mm thick , and top / middle / bottom rail of shutter with 112x44x2 mm thick , with steel thickness 2.00 mm including necessary jointing cleats glazing clips , rubber packing inclusive of 5 mm thick frosted glass / 4mm thick ACP sheet of any colour as site / users requirement with one number mortice lock per two leafs of shutter, two hinges (stainless steel 100mm size), 01 No handle (100mm per shutter) etc complete all as specified . |
| 24 | S & F in repair powder coated anodized aluminium frame for doors , windows , partitions , ventilators with one or more rebates , including joining cleaty for fixing complete all as specified . |
| 25 | S & F 5 in repair mm thick figured glass, pin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified . |
| 26 | Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed. |
| 27 | Demolition of cement concrete unreinforced in ground floors and pavingsn.exc 15 cm thickness (above or below GL) complete inclusive of removal of debris out side defence land all as specified and as directed. |
| 28 | M&L for PCC (1:2:4) type B-1, (Using 20 mm graded aggregates) 25 mm thick as in levelling course / sub base complete all as specified and directed. |
| 29 | M&L for coloured designer glazed ceramic tiles of size 300x600x7mm thick as in vertical surfaceset and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 complete. |
| 30 | M&L for light colured virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed layer in CM (1:6) al as spd and directed. |
| 31 | M&L in repair 15-18 mm thick granite (of any type) work (table rubbed and polished) in basin platform and urinal partition inclusive of cutting chases / holes if ordered as counter of wash basin platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed |
| 32 | S&F in repair\"s 18 mm thickceluka solid PVC ply of grade 1 quality of one side prelam and other side white balancing of selected colour 18mm (+/- 0.7) thick and shall provide visible edges liping by 18 mm wide x 1mm thick PVC sheet of density 600 Kg/ Cum Manufactured by an ISO-9001-2015 certified company ,using solvent cement etc fixed with screws, solvent cement /adhesive to make cupboard shutter / sides / top / bottom, shelves / partitions inside the cabinet or drawers including one no handle per shutter, 01 no of magnetic catcher per shutter / two leafs as per requirement, including 75mm size L/Z type steel hinges minimum two numbers per shutter fixed scerws openable cut 110 degree for cabinet shutter / telescopic type hinges if ordered for drawers, Make- KAFF as per ground requirementcomplete all as specified and as directed. |
| 33 | PART-III ACP PANELLINGM&L in repair panelling on wall using 3mm thick Aluminium Composite Panel (Timber Series) for cladding at walls/ partitions/ columns at places as directed, of Make : ALU Decor / Aluco Bond / Alo Bond or approved equivalent make for external walls / RCC fins / sides / soffits cladding in combination with other colours, including all necessary frame work and complete weather sealing. The composite panel should consist of 2.5mm thermoplastic core of LDPE sandwiched between 2 skins of 0.25mm thick aluminium sheet (alloy designation 310S) making a total panel thickness of 3mm. The surface will be furnished with Lumiflon based flourocarbon coating on top sides and service coating on reverse side. Coatings shall conform to specifications of specifications of ECCA / AAMA and conforming to the mechanical properties of panel as per detailed technical specifications. the system shall be fixed using anodised aluminium brackets and stainless steel bolts and nuts complete with spring washers and cap nuts and all other necessary accessories. The bracket support shall be designed as per manufactures specification and shall withstand a wind pressure of 200 kg / sqm. all hardware shall corrosion resistant frame out of anodised aluminium member. Rate shall be inclusive all hardware fittings and fixtures, adhessives, silicon etc. all complete |
| 34 | Demolition of stone slabs laid bedded and pointed in any mortor and tiles of any description or thickness in floors, aprons etc |
| 35 | Sch \"A\" Part-II (B/R)Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed |
| 36 | M&L for Elegant Fabric Tile made of perforated cement fiber composite 600X600/600X1200x5mm with square edge density 1050kg/m3 covered with fabric on the front side and Acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and are installed with Aluminium H Profile on G.I studs 600x600mm center to center 2400mmx50mm web thickness 0.5mm,flanges 15&50mm fully knurled giving it high strength,hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of 50 mm 1000 GSM thick absorbwool tested as per Fire Retardent IS 15061-2002 for excellent results complete all as specified and directed |
| 37 | M&L for preparation of old decorated surfaces of wall and applying two coat of oil bound distemper including making good the surface by filling with wall care putty making surface even and smooth, complete all as specified and as directed. |
| 38 | Sch \"A\" Part-II (E/M)M&L for point wiringfor light /fan point complete with PVC insulated unsheathed FRLSZ-H multistranded copper conductor cable conforming to IS : 694 of size 2.5 Sqmm two single core drawn through in and including flameproof stove enamelled steel concealed conduit pipe 20 mm dia with and including flameproof accessories such as tees,bends,junction box etc flame proof certification as per GP I,II,IIA &B heavy grade ISI Marked complete PVC insulated unsheathed FRLSZ-H multistranded copper conductor cable conforming to IS : 694 of size 2.5 Sqmm two single core green colour earth earth wire and connecting to earth dolly incl colour coding of cable shall be for phase, neutral and earth wire as specified in MES SSR Part I 2009 with provn of sunken galvanised not less than 1.6 mm thick MS sheet pressed terminal boxes concealed on wall for flame proof switchs/sockets, enclosure etc, withISI marked for mounting flame proof of switches/socket including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing all as specified and directed. |
| 39 | All as per Srl items No.1 here-in-beforebut point wiring with 4 Sqmm forAC Point Socket out let with 4 sqmm earth continuity. |
| 40 | Supply & Fix Flame proof switch socket &plug combined in LM6 cable termination box in LM6, 25A,250V, 2P+earth complete all as specified and directed at site |
| 41 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 42 | S & F for Flame proof sheet metal enclosure MCB DB SPN , 8 way with 200 amp rated bus bar double door DB including flameprrof MCBs(IP 43 & IK- 09 tested by ERDA & CPRI), designed and manufectured as per IS: 8623- 1 & 3, glow wire tested, colour RAL 9003 white with provision for surface and flush mounting, reversible door provsion, field fittable key lock position, removable frame, centre plate and gland plate with incoming upto MCB 40 amp , 230 V, 2 Pole complete all as specified and directed. |
| 43 | Taking down existing serviceable split type AC 1.5/2 TR capacity( indoor/ and outdoor unit ) from walland deposited to MES store for reuse after completion of civil work complete all as specified and directed at site. |
| 44 | Re- Fixing ofsplit type AC 1.5/2 TR capacity( indoor/ and outdoor unit )obtained from item ser No 6 above after completion of civil work complete all as specified and directed at site. |
| 45 | S& F AC timer with enclosure suitable for 1.5 TR/2 TR split AC complete all as specified and directed ats ite. |
| 46 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to depth not less than 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthwire of size 4.00 mmdia 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I connected to earthing lead with Main switch/main control board,filling with charcoal dustand common salt,including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC |