Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Brick work demolishing |
| 2 | Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In lime mortar with old mughal bricks |
| 3 | RCC demolition |
| 4 | Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. |
| 5 | Pcc demolishing |
| 6 | Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:4:8 or leaner mix ( including equivalent design mix) |
| 7 | Demolishing wooden door |
| 8 | Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area beyond 3 sq. metres |
| 9 | Dewatering with pump |
| 10 | Bailing out water/slush using pump above 5HP and up to 10 HP, includingconveyance to site and erection, cost of fuel, lubrication oil and other stores, pay ofstaff etc complete. All deposits/slush shall be shifted to designated location with in1km lead |
| 11 | Demolishing old iron ventilators |
| 12 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. orR.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.Bwork) as per direction of Engineer-in-charge. |
| 13 | Demolishing existing wooden partition |
| 14 | Dismantling wooden boardings in lining of walls and partitions, excluding supportingmembers but including stacking with in 50 metres lead:Upto 10 mm thick |
| 15 | Demolishing false ceiling |
| 16 | Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :Asbestos cement Sheet |
| 17 | Excavation work |
| 18 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 19 | soling |
| 20 | Soling with rough stone of size 200 mm, well packed and filling voids with stonechips and required profile with hammer dressed stones having no side less than 15cm, with minimum depth of 20 cm includingpreparing the bedding surface etc. all complete |
| 21 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 22 | RCC upto plinth level |
| 23 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 24 | Steel reinforcement work upto plinth level |
| 25 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelMild steel and Medium Tensilesteel bars |
| 26 | Solid block masonry upto plinth level |
| 27 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etccomplete |
| 28 | Bituminous painting |
| 29 | Painting with black anti- corrosive bitumastic paint of approved brand andmanufacture to give an even shade:Two or more coats on new work |
| 30 | Red earth filling |
| 31 | Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge |
| 32 | RCC for column above plinth level |
| 33 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 34 | Solid block masonry |
| 35 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in :CM 1:6 ( 1 cement : 6 coarse sand) etc |
| 36 | RCC beam |
| 37 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 38 | Steel reinforcement above plinth level |
| 39 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Cold twisted bars |
| 40 | Plastering with 12mm cement plaster mix 1:4 |
| 41 | Plastering with 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand ) |
| 42 | Ceiling |
| 43 | Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size andother end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mmrunning at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular toG.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mmlong G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and alsoincluding the cost of making openings for light fittings, grills, diffusers, cutouts madewith frame of perimeter channels suitably fixed, all complete as per drawings,specification and direction of the Engineer in Charge but excluding the cost ofpainting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 44 | Shuttering for footing |
| 45 | Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 46 | Shuttering for column above plinth level |
| 47 | Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 48 | Shuttering for beams |
| 49 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 50 | Shuttering for slab |
| 51 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 52 | Shuttering for sunshade |
| 53 | Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges |
| 54 | Shuttering for stair |
| 55 | Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 56 | Applying SBR latex mixed plaster and applying bonding agent |
| 57 | Providing, mixing and applying SBR polymer (of approved make such as NitobondSBR/SBR Reomix/Cera SBR Latex of M/s Fosroc/BASF/Cera Chem or Similiarrespectively) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer as per manufactures specification) including surface cleaning and application of bonding slurry to the prepared surface for proper adhesion as per manufacturers specificationas and directions of Engineer in chargeNote:Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made onlyafter proper wet curing has been done and surface has been satisfactorily evaluated by sounding /tapping with a blunt metal instrument of 12 mm average thickness includingscaffoldings upto 4 m height |
| 58 | Thixotropic Non shrink mortar |
| 59 | Providing and applying single component fibre reinforced thixotropic non shrinkrepair mortar such as BASF EMACO S48CT or FOSROC/BOSTIK product forcolumns, beams, slabs and otherstructural members with 4 ltrs of potable water per 25kg of product, mixing by heavyduty,slow speed drill with spiral mixing paddle or a Pan type mixers etc. afterpouring the water in a mixing vessel, mixed materialshall be applied both by trowel or spray application and finished to get a uniformthickness and finish and all works as per manufactures specifications and as directedby the Engineer in charge, including curing, cost of materials, labour, scaffoldingupto a height of 4 mtr, conveyance etcThe work shall be carried by an agency havingsufficient experience and should ensure a guarantee of 5years. Only skilled andexperienced persons shall be employed for this purpose. |
| 60 | Supply and laying first quality vitrified tiles of size 1200*600 |
| 61 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete.Size of Tile 1200x600 mm |
| 62 | Epoxy grouting |
| 63 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm or nearest |
| 64 | providing & fixing anti skid floor tile at toilet |
| 65 | Providing and fixing premium quality ceramic digital anti-skid floor tiles ofmake<br>Kajaria/Nitco/Simpolo/Cera or approved brand conforming to IS :15622 (thickness to be<br>specified by the manufacturer), in all colours, shadesof size matching to wall tiles or as approved by<br>Engineer -in-Charge, over12 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) with tilespacers 3mm and jointing with epoxy joint fillers with pigment of matchingshade of approved brand in approved pattern<br>with two or more desgin tilescomplete. |
| 66 | Providing & fixing premium quality ceramic digital wall tile |
| 67 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete |
| 68 | painting |
| 69 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 70 | Window grill |
| 71 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 72 | Aluminium Frame work for Doors windows and partitions |
| 73 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 74 | Shutter for doors and windows |
| 75 | For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 76 | UV sheet for doors |
| 77 | Providing and fixing 4 mm thick UV sheet in panelling fixed in aluminum doors,windows shutters and partition frames with C.P. brass / stainless steel screws , UVSheet finished in two diffrent colours and complete as per architectural drawings anddirections of Engineer - in-Charge |
| 78 | Glass |
| 79 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 80 | Lock for doors |
| 81 | Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 82 | Hinges |
| 83 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm |
| 84 | Handles |
| 85 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm |
| 86 | Tower bolts |
| 87 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barreltype) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)250x10mm |
| 88 | FRP door frame |
| 89 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. |
| 90 | FRP door shutter |
| 91 | Providing and fixing to existing door frames.30 mm thick Fiberglass ReinforcedPlastic (F.R.P) flush door shutter in different plain and wood finish made with fireretardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate allaround, with suitable wooden blocks inside at required places for fixing of fittingsand polyurethane foam (PUF) / Polystyrene foam to be used all filler materialthroughout the hollow panel, casted monoolithically with testing parameters of F.R.P.laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineerin-charge. |
| 92 | 25 mm PVC concealed |
| 93 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 |
| 94 | 32mm PVC concealed |
| 95 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 |
| 96 | 50mm PVC concealed |
| 97 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe6 kgf/cm2 |
| 98 | 63mm PVC concealed |
| 99 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed workincluding cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 |
| 100 | 32 mm pvc pipe exposed on wall |
| 101 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 6 Kgf/cm2 - External work - Exposed on wall |
| 102 | 50mm pvc pipe exposed on wall |
| 103 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall |
| 104 | 110mm pvc pipe trenching and refilling |
| 105 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction ofEngineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 106 | 63mm dia elbow |
| 107 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 108 | 63mm 45 degree elbow |
| 109 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 110 | 63 dia pvc door elbow |
| 111 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Door Elbow |
| 112 | 63 dia tee |
| 113 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipesincluding jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 114 | 63mm dia pvc bend |
| 115 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bend |
| 116 | 63mm dia door tee |
| 117 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63x63x63 mm dia Door Tee |
| 118 | 63mm dia vent cowl |
| 119 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia vent cowl |
| 120 | 110-63mm pvc reducer |
| 121 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110x63 mm dia Reducer |
| 122 | 63x50mm pvc reducer |
| 123 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63x50 mm dia Reducer |
| 124 | 63mm dia socket/coupling |
| 125 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia End cap |
| 126 | 63mm dia coupling |
| 127 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia End cap |
| 128 | 110mm dia elbow |
| 129 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 130 | 110mm dia 45 degree elbow |
| 131 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 132 | 110 mm dia door elbow |
| 133 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 134 | 110mm dia bend |
| 135 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 136 | 110mm dia tee |
| 137 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 138 | 110mm dia door tee |
| 139 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 140 | 110mm dia socket/coupling |
| 141 | Providing and fixing PVC moulded fittings/accessories for Rigid PVCpipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 142 | GM ball valve |
| 143 | Providing and fixing GM ball valve of approved quality (screwed end) :<br>25mm nominal bore |
| 144 | Providing and fixing CP brass bib cock long body |
| 145 | Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 146 | Providing and fixing CP brass stop cock |
| 147 | Providing and fixing C.P brass stop cock ( concealed) of standard design and ofapproved make conforming to IS: 893115 mm nominal bore |
| 148 | CP brass angle valve |
| 149 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 150 | PVC ball valves |
| 151 | Providing and fixing PVC ball valve (ISI marked) of approved brand for Rigid PVCpipes, including jointing with PVC solvent cement:<br>25mm nominal bore. |
| 152 | CP brass shower rose |
| 153 | Providing and fixing C.P. brass shower rose with arm of 15 or 20 mminlet:<br>100 mm diameter |
| 154 | SS soap Dish |
| 155 | Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge. |
| 156 | Towel rod |
| 157 | Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge. |
| 158 | Health faucet |
| 159 | Supplying and fixing CP Health faucet good quality including cost of materials andlabour charges etc. complete as per the direction of site engineer-in-charge |
| 160 | CP gratings |
| 161 | Providing and fixing CP grating of approved quality.<br>Rectangular type withopenable circular lid<br>150 mm nominal size square 100 mm diameter of theinner hinged round grating |
| 162 | Floor trap |
| 163 | Providing and fixing PVC moulded Floor trap for sanitary pipelines, including jointing PVC pipes with PVC solvent cement and filling gaps with cement groutFloor trap 4 way/3 way |
| 164 | Labour charge |
| 165 | Miscellaneous labour |
| 166 | ISMB 200 |
| 167 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved epoxy primer and 2 or more coats of epoxy paint, including welding andbolted with special shaped washers etc. complete |
| 168 | Steel reinforcement paint |
| 169 | Providing and applying anti corrosive Nitozinc primer/Cera cte SP CI/ protectosilCIT, two or more coats, over the steel reinforcement as per the manufacturesspecification including scaffolding upto height 4 mtr and as directed by Engineer-incharge. The product shall be applied on the reinforcement surface after throughlycleaning. painted area of steel shall be considered for payment |
| 170 | Orissa pattern W.C. pan |
| 171 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mmSand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, includingflush pipe, manually controlled device (handle lever) conforming to IS : 7231, withall fittings and fixtures complete, including cutting and making good the walls andfloors wherever require:White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 172 | Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked black solid plastic seat andlid |
| 173 | providing & fixing mirror |
| 174 | Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 453x357 mm |
| 175 | providing & fixing wash basin |
| 176 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 450x300 mm with single 15 mm C.P. brass pillar tap |
| 177 | Tap pvc PTMT |
| 178 | Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominalbore, 86 mm long, weighing not less than 88 gms |
| 179 | Providing new septic tank |
| 180 | Supplying and installing ready made RCC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge incl supply of CC/Sand/06mm aggregate for the preparation of bed) 35 to 50 flush capacity |
| 181 | SUPPLY PARTDISTRIBUTION BOARDS |
| 182 | Supply of 63A, 3 phase 415V 4 way Verical Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider |
| 183 | Supply of 40A, 3 phase 415V 4 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoingMake of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider |
| 184 | Supply of 25A, 3 phase 415V 6 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider |
| 185 | LIGHTING AND WIRING.LIGHT FIXTURES AND FANS, SWITCHES AND SOCKETS |
| 186 | Supply of LED downlight round (Approximate cutout dia 15cm), 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above |
| 187 | Supply of LED downlight round (Approximate cutout dia 20cm), 20W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above |
| 188 | Supply of LED wall light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above |
| 189 | Supply of LED mirror light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above |
| 190 | Supply of LED tube light batten, 4 feet, 20W (Approximate), 230V, 50Hz AC supply, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above |
| 191 | Supply of Exhaust Fan, 225 mm sweep Make:USHA/CROMPTON/BAJAJ/ORIENT/KHAITHAN/HAVELLS |
| 192 | Supply of CEILING FANMOTOR TYPE: BLDC230 V, 50 HZ, AC, 1200 MM SWEEP WITH REMOTE CONTROL AND ALL ACCESSORIESSTAR RATING: 5MAKE: ATOMBERG/CROMPTON/HAVELLS/ORIENT/LUCAS/HALONIX. |
| 193 | Supply of Electric calling bell, 230V, 50HzMake:Anchor/havells/L&T/Legrand |
| 194 | Supply of Bell switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 195 | Supply of 6A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 196 | Supply of 25A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 197 | Supply of 6A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 198 | Supply of 25A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 199 | Supply of RJ11 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 200 | Supply of RJ45 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 201 | Supply of Concealed box, Plate and frame for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 202 | Supply of Concealed box, Plate and frame for 3 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 203 | Supply of Concealed box, Plate and frame for 4 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 204 | Supply of Concealed box, Plate and frame for 6 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 205 | Supply of Concealed box, Plate and frame for 12 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell |
| 206 | Modular type wiring |
| 207 | Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 208 | Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 209 | Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 210 | Supply of materials required for circuit wiring for RJ11 in PVC medium gauge conduit with modular type switch - using telephone cable (twin flat copper PVC insulated, 2 x 0.5 sq mm, ISI marked, Make: Finolex, Anchor, V-guard, Traco, Sark, Orbit, Polycab) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets) |
| 211 | Supply of materials required for circuit wiring for RJ45 sockets in PVC medium gauge conduit with modular type switch - using CAT 6 UTP cable (Make: D-link, Finolex, Polycab, Lapp) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets) |
| 212 | Supply of materials required for wiring for Smoke Detectors in recessed PVC medium gauge conduit - using 3 x 1 sq. mm. PVC insulated copper cable in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Smoke detector)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 213 | Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 214 | Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 215 | Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) |
| 216 | Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required. |
| 217 | Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required. |
| 218 | Supply of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone |
| 219 | INSTALLATION PARTModular type wiring and Installation |
| 220 | Installation, testing and commissioning of LED downlight of all types complete with all accessories etc. in false ceiling including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required. |
| 221 | Installation of ceiling fans, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required |
| 222 | Installation of exhaust fan upto 300 mm sweep in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required |
| 223 | Installation, testing and commissioning of LED tube lights, wall lights and mirror lights of all types complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required. |
| 224 | Installation of calling bell at DCW room, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required |
| 225 | Installation, testing and commissioning of Smoke Detectors complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required. |
| 226 | Fixing of 6/25 amps modular type sockets, switches, bell switches, RJ11 and RJ45 modular sockets (other than included in point wiring) with front plate in surface or in recess including providing and fixing suitable size metal box, inter connections etc as required. |
| 227 | Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for light point/fan point/exhaust fan point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. |
| 228 | Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for socket point using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 4 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. |
| 229 | Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for calling bell point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. |
| 230 | Copper point wiring in PVC medium gauge conduit for Smoke Detector - Wiring for smoke detector point using 1/1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1/1.5 sq. mm. PVC insulated copper 3 core cable as required |
| 231 | Copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above). |
| 232 | Copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above). |
| 233 | Copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above). |
| 234 | Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required. |
| 235 | Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required. |
| 236 | LAN circuit wiring in PVC conduit - Circuit Wiring with UTP/Ethernet cable in recessed PVC conduit as required. |
| 237 | Telephone circuit wiring in PVC conduit - Circuit Wiring with two core telephone cable in recessed PVC conduit as required. |
| 238 | DB installation and Cabling |
| 239 | Installation, testing and commissioning of 63A, 3 phase 415V 4 way Verical Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider |
| 240 | Installation, testing and commissioning of 40A, 3 phase 415V 4 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoingMake of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider |
| 241 | Installation, testing and commissioning of 25A, 3 phase 415V 6 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider |
| 242 | Laying, dressing and clamping of following cables through exsisting trays / structures / racks / columns / walls etc to the new DB .Cable shall be supplied by KMML. All other materials required for clamping are under the scope of contractor. |
| 243 | (3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable |
| 244 | Glanding and termination at DB\"s side of PVC cable using DC glands/ lugs including supply of cable glands, lugs, aluminium crimping sockets, nuts bolts etc. required for this work. Gland earthing as per standards shall be done by the contractor. |
| 245 | (3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable |
| 246 | Telephone switch relocation |
| 247 | Installation, testing and commissioning of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone |
| 248 | Approval from Electrical Inspectorate. |
| 249 | Preparation of all electrical drawings and obtainig statutory approval from electrical inspectorate for the new DBs Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail