| Sl. No. | Item Description |
| 1 | (B/R PORTION)Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in hard and dense soil and getting out complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 3 | Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. |
| 4 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and cm thick, watered and rammed to a true surface of broken stonescomplete all as specified and as directed. |
| 5 | M & LPCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 6 | Form work Use and waste to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical or to batter of fair finished surfaces complete all as specified and directed. |
| 7 | Form Work Use and waste to sides of columns, pillars etc. of fair finished surfaces complete all as specified and directed. |
| 8 | Form Work Use and waste to sides and soffits of floor or roof beams, lintel, cantilevers, shelves etc. including support of fair finished surfaces complete all as specified and directed. |
| 9 | Form Work Use and waste of to sides and soffits of slabs n. exc. 200 mm thick and similar works fair finished surfaces of concrete complete all as specified and directed. |
| 10 | M&L for 40 mm thick DPC to horizontal or vertical surfaces incl necessary formwork in cement concrete 1:2:4, type B-0 all as specified and directed. |
| 11 | M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) in foundations, including rafts, footings, foundation beams ; plinth beams; bases for columns, etc ; basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 12 | M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) in columns, pillars, piers, post and struts etc complete all as specified and directed. |
| 13 | M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) inRoof Beams, cantilevers, bressummer, lintels over 1.5 span complete all as specified and directed. |
| 14 | M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) as inslab supported on wall beam and coloumn in floor roof landing balconies canopies deck slab and in shelves, etc complete all as specified and directed. |
| 15 | S&F mild steel TMT bar10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 16 | S&F mild steel TMT bar6 to 8 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 17 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 18 | M&L brick work with Fly ash bricks\" old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. |
| 19 | M & L100 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 20 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface on external surfaces in CM (1:4) & water proofing compound mixed with second layer @ 250 ml/Bag or as per manufaturer instructionfinished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly . ) |
| 21 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete as specified and directed. |
| 22 | Supplying Integral water proofing compound. |
| 23 | M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed. |
| 24 | M&L for preparation of new wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 1 to 2mm thick water proof wall care putty complete all as directed. |
| 25 | M & L two coats of cement based paint on newly plastered surface of wall including preparation and one coat of chalk whiteof serfaces complete all as specified and directed. |
| 26 | S & Fpre-paintedgalvatume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 27 | S & F pre-paintedgalvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etcfixed with self tapping screws as specified. |
| 28 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 29 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 30 | M&L False ceiling with \"E\" board \"Classic\" , reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium powder coated snap grid to support the boards/files with aluminium anodised main \"T\" section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements with 1.6mm dia GI wire and anodised adjuster and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces complete as in repair,all as specified and as directed |
| 31 | S &F framedwork such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framedwork of water tanks and similar work conforming to Fe.290 Gde E-165 complete all as specified and directed. |
| 32 | S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 33 | S&F, Powder coated aluminium Three Track sliding windowwith shutter styles 40mm x20 mm sheet thickness 1.5mm Two shutter of glass and one shutter of wire mesh consisiting ofStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 100mm x 44mm x 1.5mm thick section with or without rebate 5 mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge.Note: 1) Size of window shall be as per site requirement. 2) 5.0 mm thick Toughned glass good qualityGlass and wire cloth shall be inclusive in this Rate. |
| 34 | S & F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified Note: 1) Size of window shall be as per site requirement. 2) 5.0 mm thick Toughned glass good quality Glass and ACP Boars shall be inclusive in this Rate. |
| 35 | S & F10.0 mm thick Toughned glass good quality as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes as required complete all as specified and directed. |
| 36 | M&L Virified ceramicjoint free light colour tilesarea of each tile exc0.42 Sqm but n exc exc 1.0 Sqmand 9 to 10 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 15 mm thick screed bed cement mortar 1:6 completeall as specified and directed. all as specified and directed . |
| 37 | M&L Virified ceramicjoint free light colour tilesfor Verticle surface of area of each tile exc0.42 Sqm but n exc exc 1.0 Sqmand 9 to 10 mmthick, in as skirting/dado etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 10 mm thick screed bed cement mortar 1:3 completeall as specified and directed. |
| 38 | Demolition of Brick work / stone masonry built in cement mortar and removing the debris from MD land complete all as specified and directed. |
| 39 | Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 40 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly . ) |
| 41 | Supply only integral water proofing compound all as specified and as directed. |
| 42 | M&L for preparation of new surfaces of walls and soffit of chajja, roof slab etc by cleaning, brooming, rubbing and scrapping as required using broom, emery paper putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt headgear etc, finishing the surface with 1mm thick exterior wall putty for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified. |
| 43 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, wooden flooring of any thickness including cover fillets complete all as specified |
| 44 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. including 6mm dia Gl (upto 1200mm length) hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of Gl flat 40x3 mm size 60 mm long and expansion hold fasteners 12 5mm dia 40 mm long complete all as specified |
| 45 | Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions.All as specified and directed. |
| 46 | M&L for POP ceiling cornice of 4-6 inch width with approved design all as directed and specified. |
| 47 | M&L for Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth.all as directed and specified. |
| 48 | M&L for preparation of new surfaces and applying two coats of OBD over alkali resistant primer on ceiling, all as specified and directed. |
| 49 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including roof coverings complete all as specified and directed. |
| 50 | M&L 1.00 mm thick Plain, black, mild steel sheeting, in wall cladding, steel gates,in ridges, hips, valley gutters, drip and straight flashings and similar work cut to size, holes punch headed screws clout nails or rivets and fixed to woodor steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angle etc are required complete all as specified and directed. |
| 51 | Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. |
| 52 | Cutting Holes in brick walls in cement mortar for inserting holdfast ,pipes or steel sections and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but n exc one brick etc. all as specified and directed. |
| 53 | S&F 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lapfixed with L-type or J-type or cranked hook bolts in roof, wall etc as specified and directed. |
| 54 | M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 55 | M&L for preparation of old painted steel & iron surfaces of any description over 10 cm width or girth and applying one coat of aluminium paint complete all as specified and as directed |
| 56 | M&L for 10 mm thick seamless waterproof and termite proof WPC lovers wall panels fixed with probond adhesive and screwed to the wall etc., complete all as per manufacturer instruction, all as specified and directed |
| 57 | S&F \"L\" type PVC decorative beading(min size 15mm x 15mm) of selected quality and pattern all as specified and diected. |
| 58 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasketetc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 59 | S&F powder coated (Thickness or powder coating not less than 50 micron) anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, etc. complete all as specified and directed. |
| 60 | S&F in repairs Pre laminated 9 mm thick particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame work complete all as specified. |
| 61 | M&L for sheet glass 4.80mm thick ordinary quality obscured or frosted on one side andin squareexc 0.5 Sqm in each pane glazing with rubber gasket fixed to aluminium frame work / snap beading complete all as specified and as directed. |
| 62 | Supply and fixing in repairs aluminium (die cast) body door closer hydraulically regulated designation No 3. universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 63 | S&F in repair 150 mm over all length of cover plate of floor door stopper of Brass body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 64 | S&F aluminum anodised barrel tower bolts of extruded section 200 mm long complete all as specified and as directed |
| 65 | S&F 2 lever Mortice lock(Brass), vertical type, size 100 mm including all necessary fitting or accessoriesall as specified and directed. |
| 66 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm each and not exceeding 4 sqm removing from the site complete all as specified and directed. |
| 67 | Providing and fixing factory made uPVC white color Sliding window (area n exc 2.00 sqm each).Two track two sash with one flyscreenmade of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.] (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose). |
| 68 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 69 | M&L 5 mm thick Toughned glass as in hinged doors, partitions, windows, automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified |
| 70 | M & L for preparation of surfaces of walls and applying two coat of Oil Bound Distemper over a coat of alkali resistant primer and 1 mm thick wall care putty after complete removal of existing treatment, all as specified and directed. |
| 71 | M&L for preparation and applying two or more coats of 100% premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 2004, alkali & fungal resistance dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 liter/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm after complete removal of existing treatment, including necessary form work complete all as specified and directed. |
| 72 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 73 | S&F Non - skid Ceramic color tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and pointed in epoxy joint filler to match the shade of tilesincluding screed bed or bedding layer or mortar 15 mm thick for laying floor finishes in CM 1:4. complete all as specified and directed. |
| 74 | M&L for Glazed ceramic tiles in vertical surface 600x 300x 7mm thick as on vertical surfaces such as wall, dado, skirting etcset and jointed in neat cement slurry and pointed in colour cement to match including screed bed10 mm thick for wall tiling etc. in CM 1:3. complete all as specified. |
| 75 | M&L for 18-20 mm thick Granite slab of approved quality (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. if required including 20 mm thick for laying floor finishes in CM 1:4.as specified. |
| 76 | M&L for Providing edge moulding to 18-20mm thickness of granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. completeall as specified. |
| 77 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 78 | M&L 25 mm thick cement concrete 1:2:4 , type B0using 12.5 mm graded aggregate as in sub base for floor complete all as specified and directed. |
| 79 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 80 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 81 | M&L for sheet glass 4.80 mm thick ordinary quality obscured, figured or frosted on one side and glazing with oil putty or by other means as directed in square n. exe 0.5 Sqm in each pane complete all as specified and as directed. |
| 82 | S&F Butt Hinges medium weight cold rolled stainless steel 100mm long complete all as specified |
| 83 | S&F aluminum anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed |
| 84 | S&F Aluminum anodised bow handle fabricated type extruded section of 200 mm long complete all as directed |
| 85 | S&F Aluminum aodised sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 86 | M&L for preparation of new surfaces and applyingdistempering 2 coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.over one coat of alkali resistant primer after applying 2 mm thick wall care putty on walls, all as specified and directed |
| 87 | M&L for prepeartion of surfaces of old decorated plastered surfaces or un-plastered surfaces of ceiling and applying two coat of oil bound distermper complete on ceiling. all as specified and directed. |
| 88 | M&L for preparation of old decorated plastered surfaces or un plastered surfaces of wall and applying one coat with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.. all as specified and directed. coat of oil bound distemper complete all as specified. |
| 89 | M&L for preparation of new steel and iron surfaces of any description, n. exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 90 | Taking up or down 15 mm bore steel tubing and including cleaning for refixing or removal to store complete all as directed |
| 91 | All as per item No 90 above but 20mm bore of pipes. |
| 92 | S&F steel tubing water tubing medium grade, galvanised with all fittings of 15 mm bore and fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 93 | S&F steel tubing water tubing medium grade, galvanised with all fittings of 20 mm bore and fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 94 | Cutting chases, pinning in, making good to facings where required and pointing incement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding n exc 10cm girth complete all as specified and directed. |
| 95 | S&F in repair rotational moulded polyethylene water storage capacity 1000 litrest of anks triple layers white color (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR part I complete all as specified and directed. |
| 96 | S&F in repairs 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/20mm - 210gms/25mm-455gms/40mm - 690 gms) complete all as specified and directed. |
| 97 | Dismantling of 100 mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed |
| 98 | Dismantling of 150 mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed |
| 99 | S&F 110 mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls all as directed and specified. |
| 100 | S&F 110 mm bore PVC (SWR) Bends of any radius as required.complete all as specified and directed. |
| 101 | S&F 110 mm bore PVC (SWR) Bends with access door of any radius as required. all as specifed and directed. |
| 102 | S&F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal as required. |
| 103 | S&F PVC (SWR) vent cowl of 110 mm borecomplete all as specified and directed. |
| 104 | S&F 110mm PVC (SWR) WC connector with lip ring all as directed and specified. |
| 105 | S&F PVC (SWR) multi floor trap with grating (of 75 mm bore)including jointing with solvent cement all as specified. |
| 106 | S&F PVC (SWR) reducers for 110 mm SWR pipe from 180 mm P trap all as directed and specified. |
| 107 | S&F in repair vitreous china wash down water closet pedestal pan white excluding flushing cistern and flush pipes complete make Cera/Parryware (Slimline)/Hindware all as specified and as directed. |
| 108 | S&F in repair plastic water closet seat cover colour/ white, closed pattern with flat bottom and MS CPor aluminium hinging device as in repair of make Cera/Parryware/Hindware alumınised hinging device as in repair of make. |
| 109 | S&F in repair vitreous china wash hand basin white size 550x400 mm including bracket but excluding taps, waste pipes, chain and plug etc complete all as specified and directed. |
| 110 | S&F in repairs PVC flushing cistern push button / handle type of 10 Itr capacity coloured complete with all fitting fixed to with WC including PVC flush pipes, brackets etccomplete all as specified and directed. |
| 111 | S&F in repair PVC connection 450mm long of PTMT 15mm bore complete all as specified and directed. |
| 112 | S&F in repair 15mm bore two way bib cock, cast copper alloy fancy type chromium plated with flange complete all as specified and directed. |
| 113 | S&F PVC waste pipe 32 mm dia for WHB, 800 mm length complete all as specified and directed. |
| 114 | S&F in repair brass chromium plated grating of size 100 mm dia with waste hole complete all as specified and directed. |
| 115 | S&F in repair brass chromium plated grating of size 100 mm dia complete all as specified and directed. |
| 116 | S&F in repair looking mirror 600 x 450mm of selected quality glass mounted on 6mm commerical ply or AC building board with aluminium frame around and fixed to wooden plugs with CP brass screws all as directed |
| 117 | S&F toilet paper holder with flat recessed type stainless steel complete all as specified and directed |
| 118 | S&F in repair 15mm bore angle valves, fancy type Brass chromium plated with long shank and cup (Concealed type), all as specified. |
| 119 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 120 | S&F in repair self closing pillar taps fancy type Brass chromium plated, screwed for iron pipe 15 mm dia and fixed complete all as specified. |
| 121 | S&F brass chromium plated tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified. |
| 122 | S&F in repair15 mm bore Bib taps, fancy type brass chromium plated complete all as specified. |
| 123 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified. |
| 124 | M&L for Surface excavation on soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deepand getting out and deposite off the permises as directed. |
| 125 | S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 900 mm x 450 mm x 75 mm thick, 5 MT capacity, fixed in proper position complete as directed by Engr-in-Charge. |
| 126 | M&L providing 50 mm thick bed of plain cement concrete of type D-2, 1:4:8 (40 mm aggregate) for laying of tiles on screed bed complete all as specified and directed. |
| 127 | M&L for Spreading and levelling 50cm thick bedding of sand in layers n exc. 25 cm thick with compaction by well ramming including watering as required all as specified and directed. |
| 128 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete as specified. |
| 129 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete all as specified. |
| 130 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc ofFe 410W (Gde E-250) quality \"A\" etc complete all as specified and directed |
| 131 | M&L for Vitrified Ceramic tiles 10 mm thick light shade (of square shape) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer or mortar 15 mm thick for laying floor finishes in CM 1:4 all as specifed and directed. |
| 132 | All as per item no 131 but using as skirting/dado including screed bed 10 mm thick for wall tiling etc. in CM 1:3. |
| 133 | Refixing of anodised aluminium snap grid frame work for false ceiling of size 605x605 mm including 6mm dia Gl (upto 1200mm length) hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of Gl flat 40x3 mm size 60 mm long and expansion hold fasteners 12 5mm dia 40 mm long complete all as specified. |
| 134 | M&L anodised aluminium powder coated snap grid withframe work for false ceiling of size 605x605 mm including 4 mm dia Gl (upto 1200mm length) hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of Gl flat 40x3 mm size 60 mm long and expansion hold fasteners 12 5mm dia 40 mm long complete all as specified |
| 135 | M&L 4mm non asbestos fibre cement building boards flat, fixed or laid/inserted to timber/Gl/aluminium frame work with screws complete and applying two coats of Oil bound distemper over a coat of primer complete all as specifed |
| 136 | S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 137 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 138 | Taking down shutters of any description area exceeding 1.00 sqm and not exceeding 2.00 Sqm each and removing from the site complete all as specified and directed. |
| 139 | S&F factory made single extruded WPC (Wood polymer composite) solid door/ window / ceosetory windows & other frames/chowkats of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade) calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200N (Face) & 1100N (Edge), minimum compressive strength of 58N/mm², modulus of elasticity 900 N/mm² and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasterners of required dia and length complete as per direction of Engineer-in-Charge, (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/ window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made). |
| 140 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 141 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 142 | S&F Floor door stopper of Brass alloy body and tongue(having 140 mm overall length of cover plate) , anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 143 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as specified and directed. |
| 144 | Supplying and installing rectangular uPVC louver windows with fixed and exhaust made out of lead free green profiles having a worldwide presence with a GREENLINE mark with frame dimension of 58mm x 36mm for windows with aluminium powder coated framework and glass blades for louvers with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm The physical properties of the profiles like Vicat softening temperature density tensile strength hardness, weatherability impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system Application of Silicon sealant from Inside and Outside of Dowcorning/GE or equivalent Scaffolding if required will be charged at actuals. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted of Make Kommerling or equivalent model in Fanesta & in other makes |
| 145 | M&L 5 mm thick Toughned glass as in hinged doors, partitions, windows, automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified |
| 146 | M&L for preparation and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 2004, alkali & fungal resistance dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 liter/10 sqm over and including priming coat of exterior primer applied @ 0 90/litre/10 Sqm over 2 mm thick exterior wall care putty of new surfaces, all as specified and directed |
| 147 | M&L for preparation of old decorated plastered surfaces or un plastered surfaces of ceiling and applying one coat of oil bound distemper complete all as specified |
| 148 | (E/M PORTION)Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings suchasswitches,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 149 | M & L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches, sockets, fan regulators etc for the following |
| 150 | All as per Item No 149 above but one light point or one fan pointor bell point controlled by one switch |
| 151 | All as per Item No 149 above but one 3 pin socket outlet, 5 Amp independent |
| 152 | All as per Item No 149 above but one 3 pin socket outlet, 5 Amp on the same board with other switches |
| 153 | All as per item No 149 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke (FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed. |
| 154 | S & F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 155 | S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed. |
| 156 | S & F Modular Socket 6 A- 2/3 pin combined 2 module complete all as specified and directed. |
| 157 | S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 158 | S & F Modular type White cover plate with frame 12 module complete all as specified and directed. |
| 159 | S & F Modular type Metal Flush box 12 module complete all as specified and directed. |
| 160 | S&F Ceiling rosethree terminals polycarbonate , isolated body completeall as specified and directed. |
| 161 | S & FSocket for AC short circuit protection motor starterwith MCB DP 25 Amps capacity AC230 Volt with Plug Top with Indicator complete all as specified and directed. |
| 162 | Supply and fixing copper cable2.5 sqmm 4 core duly connected and properly clampedfrom indoorunitto Outdoor unit complete all as specified and directed |
| 163 | S & F PVC Cable trays with cover of size 75mm X 75mmon walls / ceilings as per site requirement for properfixing of Copper pipe with insulation alongwith fittings and fixtures arrangementcomplete all as specified and directed. |
| 164 | Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :-(a)50 Sqmm, 3.5 Core |
| 165 | S & F in repairLED Ceiling light fitting 35/36 Wrecess / Surface type as in repair, minimum colour temperature 6500K, with suitable driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specifide and directed. Make: Crompton LCTLSN-36-CDL or equivalent make specified in tender. |
| 166 | M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and includin PVC casing-caping of suitable size, surface type all as directed. |
| 167 | All as per Srl. Item No.163above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor. |
| 168 | All as per Srl. Item No. 163 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor. |
| 169 | S & F TP&N Vertical Loadline Dbs are fitted with Bus Bars, Neutral Links, Blanking Plates 6 way double door DB LL 4W DD VERT W/O MCCB.complete all as specified and directed. |
| 170 | S & F MCCBs 415V, 16KA, 4 Pole 100 Amps complete all as specified and directed. |
| 171 | S & F MCB \"C\" series single pole 5 to 32 Amps, breaking capacity 10KA.complete all as specified and directed.Make: Cat No. 408587 of Legrandor equivalent make specified in tender. |
| 172 | Supply, installation and commissioning of 3 phase 415 volts Air Cooled vertical type Air Conditioner energy with minimum 3 star rating indoor and outdoor completed with cordless remote control unit, scroll compressor of capacity 3.0 ltr complete all as specified and directed. Make Model No FVRN100AXV16 of Daikin/Hitachi/O-General or equivalent make specified in tender. |
| 173 | S & F Modular type White cover plate with frame 3 module complete all as specified and directed. |
| 174 | S & F Modular type White cover plate with frame 8 module complete all as specified and directed. |
| 175 | S & F Modular type Metal Flush box 3 module complete all as specified and directed. |
| 176 | S & F Modular type Metal Flush box 8 module complete all as specified and directed. |
| 177 | S & F Double door sheet metal enclosure for DBs(Premium range) for mounting of MCB for 240 Volts 8 Way with 100 Amps rated copper bus bar,single pole and Neutral complete all as specified and directed. |
| 178 | Supply only MCB, \"C\" series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. |
| 179 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail