| 1 | Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed. |
| 2 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 3 | Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed. |
| 4 | Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed. |
| 5 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping of poles etc including form work for poles all as specified and directed by Engr-in-Charge. |
| 6 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles (bed concrete) all as specified and directed by Engr-in-Charge. |
| 7 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete of poles including form work for poles all as specified and directed by Engr-in-Charge. |
| 8 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 50 Sqmm 3.5 core as per IS 7092 Pt -I including taking out old u/s existingLT cable complete all as specified and directed. |
| 9 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 25 Sqmm 4 core as per IS 7092 Pt -I including taking out old u/s existingLT cable complete all as specified and directed. |
| 10 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 16 Sqmm 4 core as per IS 7092 Pt -I including taking out old u/s existingLT cable complete all as specified and directed. |
| 11 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 10 Sqmm 4 core as per IS 7092 Pt -I including taking out old u/s existingLT cable complete all as specified and directed. |
| 12 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls/ pole including all connections, accessories like socket, couplers, bends etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-charge. |
| 13 | S&F of kiosk box for luminaires ,weather proof made out of PVC FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole mounting type comprising of copper connector 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over ared oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box including taking down old u/s existing kiosk box complete all as specified anddirected |
| 14 | M & L for earthingcomplete with galvanized steel earth plate electrode600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level)with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to galvanised earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and saltand protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit .On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item. |
| 15 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided withtwo coats of aluminium paint overone coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. |
| 16 | Supply, erecting and fixing in replacement of true vertical position, prestressed concrete pole 9.0 mtr long102mm x 152mm at topand 102mmx289mmat bottom, class 10 (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size) including taking down of old unserviceble pole & shifting of cross arms ACR conductor , GI wire, insulator, street light brackets etc complete all as directed. Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. The old unserviceable pole obtained from dismanting shall be remove by the contractor form cantt area/MOD. If the contractor has not removed the dismantled item a penality of Rs.500.00 per pole will be charged from the contractor as a penality. |
| 17 | S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade,1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed. |
| 18 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 60 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 kv in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specifiedand as directed.Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 19 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 90 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 kv in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specifiedand as directed.Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 20 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 120 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 kv in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specifiedand as directed.Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 21 | S&F in replacement of LED flood light 80 watt 230Volt,AC outdoor type high performance with pressure die cast housing, toughened glass and secondary lens opticswith IP-66 ingressprotection, efficacy 120 Im/W complete with driver and lamp all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 22 | S&F in replacement of LED flood light 100 watt 230Volt,AC outdoor type high performance with pressure die cast housing, toughened glass and secondary lens opticswith IP-66 ingressprotection, efficacy 120 Im/W complete with driver and lamp all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 23 | S&F in replacement of LED flood light 120 watt 230Volt,AC outdoor type high performance with pressure die cast housing, toughened glass and secondary lens opticswith IP-66 ingressprotection, efficacy 120 Im/W complete with driver and lamp all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 24 | Supply and fixing post top lantern LED 25 watt 230 watt volts AC outdoor type made in die cast alumnium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP-65 protection opal diffuser complete all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 25 | Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole 6 mtr height in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. Note :-Excavation, earth work and PCC foundation shall be measured separately) Make:- CG/Wipro/Bajaj/Havells/Phillips/Halonix |
| 26 | S&F in replacement ofLED bollard/garden light stailess steel 9 watt weather prooflight (warm white) with opal acrylic diffuser, IP-66 protection complete with all accessaries including excavation and grouting with PCC foundation complete all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips/HalonixNote:-(i) Warrantty for replacement of each LED bollard light fitting shall not be less than 02 years from date of pruchse. |
| 27 | M&L for restringing of LT/street light overhead line conductor comprising of any sizeACSR conductorafter opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sagcomplete all as directed. |
| 28 | M&L for Cutting and trimming of tree branches of any girth all around the HT/LTover head lines upto two mtr from all around the over head lines complete and removing the cut branches from site to a distance not exc 50 mtr all as directed. Note:- T&P required for cutting/trimming of tree branches shall be provided by contractor without any extra cost. |
| 29 | S&F MCB 63 Amp TPN\"C\" series for street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand |
| 30 | S&F MCB 6 - 32 Amp SPN for street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand |
| 31 | S&F MCB 63 Amp SPN \"C\" seriesfor street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand |
| 32 | Taking down carefully aluminium/copper point wiring (sub station bldgs)complete,including fixture and fitting such as switches,ceiling roses,pendents,regulators,sockets,light fitting etc.removing materials to storefor keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making goodthe disturbedsurfaces of walls, Floors, ceilings etc completeall as specified and as directed. |
| 33 | M & L forconcealed point wiring for one light point controlled by one switch withPVC insulated and unsheathed electric cable 1100 volts grade FRLSH conforming to IS 694:2010 having multisranded copper conductor of 1.5Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade (ISI marked with valid CML No ) not less than 20mm dia with all fitting and fixing accessories and 1.5Sqmm FRLSH conforming to IS 14930(Part-I) 2001, PVC insulated unsheathed multistranded copper conductor as continuous earth conductor , concealed to continuous earth dolly by providing suitable lugs with and including pressed steel sunkenterminal boxes/modular flux box factory made for mounting switch , regulators etc with and including 2.8mm thick plastic laminated sheet cover(white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminius paint outside and two coats of aluminium paint inside for mounting switches etc complete all as specified and as directed |
| 34 | S&F ceiling rose,surface Polycarbonate 65 x50mm three terminals completeall as specified and asdirected. |
| 35 | S&F switch piano type, single pole, one way, 6 amps, 240 volts, ISI marked with valid CML complete all as specified and directed. |
| 36 | S&F in replacement ofPVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI markedthree core cable flat or circular of size 6 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connectionsetc complete all as specified and direcetd. |
| 37 | S&F in replacement ofPVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI markedthree core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connectionsetc complete all as specified and direcetd. |
| 38 | S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulatedcopper conductor three core cable flat or circular of size 1.5 sqmmfor street light connectionsetc complete all as specified and direcetd. |
| 39 | S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulatedcopper conductor three core cable flat or circular of size 2.5 sqmmfor street light connectionsetc complete all as specified and direcetd. |
| 40 | S&F in replacement aluminium lugs/thimble suitable for LT XLPE cable of size 10 Sqmm to 16 Sqmm complete all as specified and directed |
| 41 | S&F inreplacement aluminium lugs/thimble suitable for LT XLPE cable of size 25 Sqmm to 50 Sqmm complete all as specified and directed |
| 42 | S&F in replacement of LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 30 watts to 60 watts including replacement of burnt drivers carefully and as direcetd |
| 43 | S&F in replacement of LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 70 watts to 90 watts including replacement of burnt drivers carefully and as direcetd |
| 44 | S&F in replacement of LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 100 watts to 150 watts including replacement of burnt drivers carefully and as direcetd |
| 45 | S&F in replacement of heat shrinkable LT straight through joints suitable for 06- 16 Sqmm 4 core cable including jointing with copper lugs and ferrules complete all as specified and directed. |
| 46 | S&F in replacement of heat shrinkable LT straight through joints suitable for 25- 50 Sqmm 3.5/4 core Sqmm cable complete all as specified and directed. |
| 47 | Supply & fixing GI tube 50 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge. |
| 48 | S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed. |
| 49 | Supply & fixing in repair of three phase 415 V automatic street light timer switch of capacity 12 KW using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 40 Amps - 03 Nos(b).Contactor rating 40 Amps - 03 Nos(c).Out put MCBrating 40 Amps - 03 Nos(d).Three phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e) Model No :- SWADEEP -02EC 12 KW 3 P- VMS. Make :- Kakatiya Energy Systems Ltd(f). Voltage monitoring - Device (SM500 Make -GIC/L&T)-01 Nos.Note:-(i) 01 year Guarantee + 01 year Warranty on sensor & 01 year warranty on remaining other items from date of purchase. |
| 50 | Supply & fixing in repair of single phase automatic street light timer switch of capacity 8 kw using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, openable doors with lock including taking down of u/s existing timer panel complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 8 KW and street light timer should be comprising of following:-(a). Input MCB rating 63 Amps - 01 Nos(b).Contactor rating 63 Amps - 01 Nos(c).Out put MCBrating 63 Amps - 01 Nos(d).Single phase circuit wiring minimum 16 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -02EC 8 KW1P- VMS. Make :- Kakatiya Energy Systems Ltd(f). Voltage monitoring - Device (SM500 Make -GIC/L&T)-01 Nos.Note:-(i) 01 year Guarantee + 01 year Warranty on sensor & 01 year warranty on remaining other items from date of pruchse. |
| 51 | M&L for painting of steel tubuler 11/9 mtr poles any type complete incl flat iron clamps,D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint (Ist quality of manufacturer )and also including numbering of poles with white paint are located on different locationscomplete all as specified and directed . |
| 52 | M & L for cutting of road up to 0.75m deep suitable for laying underground cable/MS tubes of any size/dia including GI pipe of 50mm dia and making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50mtrscomplete all as specified and directed. |
| 53 | M&L for providing and fixing retro reflective high intensity prismatic (HIP) tape on steel tubular/PCC pole specified colour, 75-100mm wide including surface cleaning, rust removal wiping with solvent, cutting tape to required length wrapping around pole with firm adhesion and ensuring uniform alignment and finishing labour, tools and incidental charge complete all as specified and directed by Engr-in-Charge |
| 54 | M&L for providing and fixing tri colour LED light strip of 18 mtr (saffron, white and green) around the pole out door grde IP-65 LED strip with uniform illumination complete with clamps, driver, wiring and commissioning all as specified and as directed by Engr-in-Charge. |
| 55 | S&F in repair/replacement of plastic LEDkerb stones light as per existing sample or user requirement complete all as specified and as directed. |