| 1 | M&L taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | M&L taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or for taking credit (credit for above items should be made as per conditions separately) complete all as specified and directed. |
| 3 | M&L in repairpoint wiring using approved colour coding as per IS controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits concealedsuitable for 20 Amp sheet metal enclosure including 4 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with theexisting specifications complete all as specified. |
| 4 | M&L in repairpoint wiring using approved colour coding as per IS controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits on surfacesuitable for 20 Amp sheet metal enclosure including 4 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with theexisting specifications complete all as specified. |
| 5 | Supply and fix in replacement of single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB of capacity 20 Amp including taking down all as specified and as directed. |
| 6 | M&L in repairpoint wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits in concealed with sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with theexisting specifications complete all as specified. |
| 7 | All as per serial item No.6.00 here-in-before but for size 1.5 Sqmm onIndependent board complete all as specifiedand directed |
| 8 | All as per serial item No.6.00 here-in-before but for size 1.5 Sqmm on sameboard complete all as specifiedand directed |
| 9 | All as per serial item No.6.00 here-in-before but for size 2.5 sqmm for 15 amp socket on independent board complete all as specified and directed |
| 10 | M&L in repairpoint wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduit in surface with sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with theexisting specifications complete all as specified. |
| 11 | All as per serial item No.10.00 here-in-before but for size 1.5 Sqmm onIndependent board complete all as specifiedand directed |
| 12 | All as per serial item No.10.00 here-in-before but for size 1.5 Sqmm on sameboard complete all as specifiedand directed |
| 13 | All as per serial item No.10.00 here-in-before but for size 2.5 sqmm for 15 amp socket on independent board complete all as specified and directed |
| 14 | Supply and fix Switch Piano,flush type 6 Amp single pole,oneway conforming to IS-3854 complete all as speciifed and as directed |
| 15 | Supply and fix outlet socket 3 pin 6 amp fllush type compelete all as specified and directed. |
| 16 | Supply and fixoutlet socket combination 6 Amp complete all as specified and directed |
| 17 | Supply and fix outlet socket 3 pin 16 amp fllush type compelete all as specified and directed. |
| 18 | Supply and fix Switch Piano,flush type 16 Amp single pole,oneway conforming to IS-3854 complete all as speciifed and as directed |
| 19 | M&L in repair ofPoint wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for concealed phase & neutral drawn throughPVCcashing capping on surface with new modular boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with theexisting specifications complete all as specified. |
| 20 | All as per Serial item No.19.00 here-in-before but for one 5/6 Amps socket outlet on the Independent board suitable for modular accessoried complete all as specified |
| 21 | All as per Serial item No.19.00 here-in-before but for one 6 Amps socket outlet on the same board suitable for modular accessoried complete all as specified |
| 22 | All as per serial item No.19.00 here-in-before but for 2.5 sqmm for 15 amp socket on independent board complete all as specified and directed complete all as specified |
| 23 | Supply and fixmodular switch , 1 way 6 Amp 1 module singe pole one way complete all as specified and directed |
| 24 | Supply and fixmodular socket outlet 2/3 pin, 6 amp complete all as specified and directed. |
| 25 | Supply and fixmodular switch , 1 way 16 Amp 1 module singe pole one way complete all as specified and directed |
| 26 | Supply and fix modular socket outlet 2/3 pin, 16 amp complete all as specified and directed. |
| 27 | Supply andfixCeiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed. |
| 28 | M&Lin repairSub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface/concealed in PVC casing caping/ PVC conduit, heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiringand disposing from site complete all as specified and as directed.Note: Two runs each of 4.00 sqmm main cable andone RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 29 | M&Lin repairSub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface/concealed in PVC casing caping/ PVC conduit heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiringand disposing from site complete all as specified and as directed.Note: Two runs each of 6.00 sqmm main cable andone RM of 6 .00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 30 | M&LSub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface cashing capping, heavey duty and connected to main board and making good disturbed surfacecomplete all as specified and as directed.Note: Two runs each of 10.00 sqmm main cable andone RM of 10.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 31 | M&LSub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn throughrigid Surface/concealed in PVC casing caping/ PVC conduit , heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiringand disposing from site complete all as specified and as directed. Note: Two runs each of 2.5sqmm cable andone RM of 2.5 sqmm cable as earth wirealongwith conduit shall be considered as one running metre for payment purpose. |
| 32 | M&LSub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.5 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface cashing capping, heavey duty and connected to main board and making good disturbed surfacecomplete all as specified and as directed.Note: Two runs each of 1.5 sqmm main cable andone RM of 1.5 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 33 | M&L in repairof PVC conduit of size 20 mm ISI marked laying in roof/wall including fixing arragement like saddledd and other material complete all as specified and directed. |
| 34 | S&F in repair ofBuilding securityLED street light fitting 35 Watt 6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistantcomplete with driver, lampfixing of wall,pole,buildingwith impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protectioncomplete all asspecified and as directed. |
| 35 | S&F in repair Street light bracket made out of 32/40 mm dia GI light grade tubing not less than .75 Mtr long bend to shape including pole clamps/fastners clips nailsmade outflat iron and nuts, bolts and washers etc complete all as specified and directed. |
| 36 | S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, single door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. |
| 37 | S&F sheet steel powder coated distribution board SPN 8 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, single door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. |
| 38 | S&F sheet steel powder coated distribution board SPN 12 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, single door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. Note on Item No 36 to 38 : MCB SP/SPN will be measured and paid seperately under respective schedule. |
| 39 | M&L in repair MCB SPN40 Amps, 240 Volts, having breaking capacity 10 kA, \"C\" characterstic complete all as specified and as directed. |
| 40 | M&L in repairMCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, \"C\" characterstic complete all as specified and as directed. |
| 41 | Supply and fix factory made V TPN DBs-DPX-160 MCCB DB\"s, IP-43 protection-IK09 with metal double door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and included with SP/TP MCB\"s as outgoing 4 way DPX 3 160+12 etc complete all as specified and directed |
| 42 | Supply and fix factory made V TPN DBs-DPX-250 MCCB DB\"s, IP-43 protection-IK09 with metal double door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and included with SP/TP MCB\"s as outgoing 4 way DPX 3 250+12 etc complete all as specified and directed Note on Item No 41 to 42 : MCCBwill be measured and paid seperately under respective schedule. |
| 43 | Supply and fixing MCCBs 250 Amps capacity, DPX-250 415 volts, 4 pole, 25 KA,thermal magnetic complete all as specified and directed. |
| 44 | Supply and fixing MCCBs 160 Amps capacity, DPX-160 415 volts, 4 pole, 25 KA,thermal magnetic complete all as specified and directed. |
| 45 | Supply and fixing MCCBs 100 Amps capacity, DPX-160 415 volts, 4 pole, 25 KA,thermal magnetic complete all as specified and directed. |
| 46 | Supply and Fix MCCB TPN 415 Volts, 100 Amps, 50 Hz, 16 KA \"C\" series allas specified and directed. |
| 47 | Supply and Fix MCCB TPN 415 Volts, 63 Amps, 50 Hz, 16 KA \"C\" series allas specified and directed |
| 48 | S&F in repair Recess mounting type fittingLED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2\" x 2\" (Appx) system wattage36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, Surge Protection>2 KV,IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. |
| 49 | Supply and fix in replacement of LED lights fitting Fourfeet 1x 20 Watt LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down all as specified and directed by Engr-in-Charge. |
| 50 | Supply and fix in replacement of LED lights fitting Twofeet 1x 10 Watt LED 6500 K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down all as specified and directed by Engr-in-Charge. |
| 51 | Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 35 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid.(ii) Excavation & earth work will be measured and paid separately. |
| 52 | All as per item No 51 hereinbefore of size 25 Sq.mm 3.5 core complete all as specified and directed. |
| 53 | All as per item No 51 hereinbofore but cable of size 16 Sq.mm 4 core, complete all as specified and directed. |
| 54 | All as per item No 51 hereinbofore but cable of size 10 Sq.mm 4 core, complete all as specified and directed. |
| 55 | All as per item No 51 hereinbofore but cable of size 10 Sq.mm 2 core, complete all as specified and directed. |
| 56 | M&L Earthing complete with Galvanised steelearth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit andpit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site complete all as specified and directed. |
| 57 | M&L Earthing complete with Galvanised steelearth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth strip of size 32 x 6 mm as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit andpit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site complete all as specified and directed. |
| 58 | Material and Labour for earth continuity conductor or main galvanised iron wire of size 4.00 mmburried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 59 | Material and Labour for earth continuity conductor or main galvanised iron strip of size 32 x 6 mmburried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 60 | Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out,, complete all as specified and directed by Engineer-in-Charge |
| 61 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge |
| 62 | Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed by Engineer-in-Charge |
| 63 | M&L for dry sand cushioning to underground cablescomplete all as specified and directed.Note : Only punned thickness i.e. 18 CM shall be measured and paid. |
| 64 | M & L for sub class \"B\" brick for covering to under ground cable laid flat transversally width equal to the lenth of the cable complete all as specified and directed. |