| 1 | Demolition of plain cement concrete (Unreinforced) in benching and surface channels, bedding etc above ground level complete all as specified and directed. |
| 2 | Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 150 mm dia complete all as specified and directed. |
| 3 | Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 200 mm dia complete all as specified and directed. |
| 4 | Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 300 mm dia complete all as specified and directed. |
| 5 | Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes, etc. n getting out any type of soil in foul water position complete all as specified and directed. |
| 6 | Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes, etc. n getting out any type of soft rock in foul water position complete all as specified and directed. |
| 7 | M&L for 150mm dia RCC pipes class NP-2 with collars laid in trenches with cement joint and tested including cement concrete 1:4:8 type D2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 8 | M&L for 200mm dia RCC pipes class NP-2 with collars laid in trenches with cement joint and tested including cement concrete 1:4:8 type D2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 9 | M&L for 300mm dia RCC pipes class NP-2 with collars laid in trenches with cement joint and tested including cement concrete 1:4:8 type D2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 10 | M&L for plain cement concrete 1:3:6 type C2 using 20mm graded aggregateas in foundation, filling in mass concrete complete all as specfied as directed. |
| 11 | M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded aggregate as in benching/kerbing or surface channel etc complete all as specified and directed. |
| 12 | M&L for plain cement concrete 1:3:6 type C1 using 20mm graded aggregate as in coping including form work etc complete all as specified and directed. |
| 13 | Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed. |
| 14 | M&L for Pre-cast cement concrete block masonry with solid blocks, type D-5, 1:5:8, exc. 10 cm in width and setting in mortar, complete, built in cement mortar (1:6) complete all as specified and directed. |
| 15 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 16 | M&L for rendering 15mm thick in cement mortar 1:4 on brick surfaces / concrete finished even smooth with spong finish without using extra cemnet complete all as specified and directed. |
| 17 | M&L for cutting in to existing manhole for connectiing new drain 150/200/300 mm bore, making good to pipe & renderring cutting out existing benching for & forming branch channel in cement concrete ( 1:2:4) type B1 smooth finished & reforming benching as requierd complete all as specified and directed. |
| 18 | Returning filling in soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc all complete all as specified and directed. |
| 19 | Removing excavated soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 20 | M&L for extra forming fair finished drain or channel inner girth n.exc 30 cm in cement, concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 21 | M&L for extra forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement incl, forms mould, mitred/stopped ends etc complete all as specified and directed. |
| 22 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash complete all as specified and directed. |
| 23 | M&L for PCC block wall septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 design mix in roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.8 meter and overall depth of 2.85 meter for 300 users complete all as specified and directed. Note : Drg No CEPZ/93/TD/12-STR dt 17.05.2007 Sheet No 1/1 |
| 24 | M&L for soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC filled with brick bats of size 3mx6m complete all as specified and directed.Note : Drg No CEAA/TD/54 dt 18.07.1998 Sheet No 1/1 |
| 25 | M&L for cement concrete work in pavement/ hard-standing of flexural strength 40 kg/square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed. |
| 26 | Dismantaling stone slabs and tiles of any description or thickness in floors, laid dry or aprons etc complete all as specified and directed. |
| 27 | M&L for machine pressed coloured glossy finish precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 grade including 30 mm thick grit/stone dust cushioning complete all as specified and directed. |
| 28 | Fixing only interlocking tiles of any thickness and size including 30 mm thick sand cushoning complete all as specified and directed. |
| 29 | M&L for precast factory made SFRC (Steel fibre reinforced concrete) manhole cover with frame of following specification for heavy duty including groove & hook arragement for lifting and placing in position complete all as specified and directed. (a) Clear Opening : 600mmx900mm (b) Cover size : 700mmx1000mm (c) Thickness of cover : 100mm (d) Frame outside diamention : 830mmx1150mm (e) Thickness of Cover frame : 150mm (f) Resting length : 75mm (g) Grade of concrete : M-30 |
| 30 | M&L for precast factory made SFRC (Steel fibre reinforced concrete) manhole cover with frame of following specification for heavy duty including groove & hook arragement for liftingand placing in position complete all as specified and directed.(a) Clear Opening : 600x600mm (b) Cover size : 700mmx700mm (c) Thickness of cover : 100mm (d) Frame outside diamention : 820mmx820mm (e) Thickness of Cover frame : 150mm (f) Resting length : 50mm (g) Grade of concrete : M-30 |