| 1 | Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole complete all as specified and directed. |
| 2 | Dismantling/taking down of ACSR conductor from OH pole/line of any size, from insulator etc complete all as specified and directed. |
| 3 | Dismantling insulators any type, size complete all as specified and directed. |
| 4 | Dismantling electric pole any type, size complete all as specified and directed. |
| 5 | M&L for mild steel cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including taking down unserviceable/old cross arms, complete all as specified and directed. |
| 6 | M&L in replacement of ACSR conductor Weasel type including stretching, fixing and binding to insulator on OH LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified and directed. |
| 7 | M & L for pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, one galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 (LT) volts grade. Including taking down oldunserviceable pin insulator complete all as specified and directed. |
| 8 | M&L in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel \"D\" clamp straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified and directed. |
| 9 | Taking down the existing unserviceable distribution LT panel board with conventional type switches, unserviceable MCCBs from Panel boards, controls and removing from site for further disposal complete all as specified and directed. |
| 10 | Supply, assembly, erection, testing and commissioning of Electrical panel cubical indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated as per CPRI approved make specified in CA, floor mounted free standing made out of 2 mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 1000A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears,including suitable size of necessary PCC (1 : 3 : 6) type C2 as in foundation/coping complete all as specified and directed. |
| 11 | a)Aluminium Bus bar 1000 Amps capacity TPN, full for phase andneutral with colour code PVC sleeves. - 01 Job Note :- MCCBs shall be micro processor/adjustable type as per site requirement. |
| 12 | b)LED RYB indicating lamps – 01 set |
| 13 | c) LED Ammeter and voltmeter with necessary CTs and displayof requiredrating . |
| 14 | d)MCCB 200 Amp, 36KA4 Pole 415 Volts- 1 Nos (Incomer) |
| 15 | e)MCCB 100Amp, 16KA4 Pole, 415 Volts - 02 Nos (Out going) |
| 16 | (f) MCCB 63 Amp, 16KA4 Pole, 415 Volts - 01 No (Out going) |
| 17 | g) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job |
| 18 | h)Interconnection of busbar with MCCB, contactor with suitable size aluminiun strip - 01 Job |
| 19 | j)Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed.- 1 Job |
| 20 | Supply, assembly, erection, testing and commissioning of Electrical panel cubical indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated as per CPRI approved make specified in CA, floor mounted free standing made out of 2 mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 1000A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears,including suitable size of necessary PCC (1 : 3 : 6) type C2 as in foundation/coping complete all as specified and directed. |
| 21 | a)Aluminium Bus bar 1000 Amps capacity TPN, full for phase andneutral with colour code PVC sleeves. - 01 Job Note :- MCCBs shall be micro processor/adjustable type as per site requirement. |
| 22 | b)LED RYB indicating lamps – 01 set |
| 23 | c) LED Ammeter and voltmeter with necessary CTs and displayof requiredrating . |
| 24 | d)MCCB 400 Amp, 36KA4 Pole 415 Volts- 1 Nos (Incomer) |
| 25 | e)MCCB 250Amp, 36KA4 Pole, 415 Volts - 01 Nos (Out going) |
| 26 | (f) MCCB 200 Amp, 16KA4 Pole, 415 Volts - 02 No (Out going) |
| 27 | g)Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job |
| 28 | h)Interconnection of busbar with MCCB, contactor with suitable size alminium strip - 01 Job |
| 29 | j)Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed. - 1 Job |
| 30 | Supply, assembly, erection, testing and commissioning of Electrical panel cubical indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated as per CPRI approved make specified in CA, floor mounted free standing made out of2 mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 1000A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears,including suitable size of necessary PCC (1 : 3 : 6) type C2 as in foundation/coping complete all as specified and directed.. |
| 31 | a)Aluminium Bus bar 1000 Amps capacity TPN, full for phase andneutral with colour code PVC sleeves. - 01 Job Note :- MCCBs shall be micro processor/adjustable type as per site requirement. |
| 32 | b)LED RYB indicating lamps – 01 set |
| 33 | c) LED Ammeter and voltmeter with necessary CTs and displayof requiredrating . |
| 34 | d)MCCB 200 Amp, 36KA4 Pole 415 Volts- 1 Nos (Incomer) |
| 35 | e)MCCB 100 Amp, 16KA3 Pole, 415 Volts - 02 Nos (Out going) (For star Delta starter) |
| 36 | (f) MCCB 63 Amp, 16KA4 Pole, 415 Volts - 01 No (Out going spare) |
| 37 | (g) Star Delta Starter, panel mounted/housing for 20 HP submersible pump,3 phase,IP 54, FRLSH internal wiring, over load relay range 15A to 25A - 02 Nos |
| 38 | h)Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job |
| 39 | j)Interconnection of busbar with MCCB, , contactor with suitable size alminium strip - 01 Job |
| 40 | k)Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed.- 1 Job |
| 41 | Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable as in any type of soil and getting out, complete all as specified and directed. |
| 42 | All as per ser item No 15 above but depth exceeding 1.5 m and not exceeding 3 m. |
| 43 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. |
| 44 | Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed. |
| 45 | Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying,complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and directed. |
| 46 | Material and labour for kiln burnt Sub class \"B\" bricks laid dry , flat , width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed. |
| 47 | Material and labour for Cement concrete in Bed of poles streets and stays 1:4:8 type D-2 using 40 mm graded crushed stone aggregate complete all as specified and directed.. |
| 48 | Material and labour for Cement concrete 1:2:4 type C-2 using 40 mm graded crushed stone aggregate as in pole coping and stay assembly complete all as specified and directed. |
| 49 | Material and labour for Cement concrete in foundation of poles streets and stays 1:3:6 type D-2 using 40 mm graded crushed stone aggregate complete all as specified and directed. |
| 50 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide including taking down old one complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 51 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-55 (11 metres long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide including taking down old one complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 52 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Connection cable as required including taking down old one complete all as specified and directed. |
| 53 | Supply and fix street light control junction box 200x160x98mm made out ofthermoplastic and arrangement of incoming 3 phase 4 wire system and out going 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 6 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable to pole of any size with bolts nuts & washers including taking down old one complete all as specified. NOTE: - The unit rate quoted shall be deemed to includes for incoming & outgoing cables glands& lugs of size up to 25/16/10 sqmm 4 core. |
| 54 | S & F bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm including taking down old one complete all as directed by Engr-in-Charge. |
| 55 | Supply and fixing 40 mm dia light grade GI pipe with fittings, laid in trenches/wall/pole for protection of underground cable to Junction Box complete all as specified and directed. |
| 56 | Supply and fixing 50 mm dia light grade GI pipe with fittings, laid in trenches/wall/pole for protection of underground cable to Junction Box including taking down old one complete all as specified and directed. |
| 57 | Supply & FixingMultistranded Copper Conductor cable of3 Core 1.5 Sq mm FRLSH for connection ofjunction box to light complete all as directed by Engr-in-Charge. |
| 58 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one 2 core cable of size 16 Sqmm including dismantling the existing unserviceable cable complete all as specified and directed. |
| 59 | Taking up the unserviceable XLPE LT UG cable 3.5/ 4 core 16 Sqmm to 95 Sqmm from trenches or walls complete all as specified and as directed. |
| 60 | S & FXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core 95 sqmm cross sectional area in trenches or walls complete all as specified and as directed. Note: for SI Nos 32 to 37 : 1. Excavation & Earth work sand cushioning GI Pipe and brick for cable protection will be measured and paid separately. |
| 61 | All as per item No. 32 above3.5 core 70 Sqmm |
| 62 | All as per item No. 32 above3.5 core 50 Sqmm |
| 63 | All as per item No. 32 above3.5 core 35 Sqmm |
| 64 | All as per item No. 32 above3.5 core 25 Sqmm |
| 65 | All as per item No. 32 above3.5/4 core 16 Sqmm |
| 66 | S&FMCCB (AC 415V) 4 pole 400 Amp 50 KA Conforming to IEC:60947-II / IS:13947-II) adjustable thermal and adjustable magnetic type including dismantling the unserviceable MCCB including taking down old one complete all as specified and as directed. |
| 67 | S & F MCCB 4 pole 200A, 36 KA including dismantling the existing unserviceable MCCB complete all as specified and directed. |
| 68 | All as per item No. 39 abovebut 4 pole,125/100 Amp Capacity 25 KA MCCBincluding dismantling the existing unserviceable complete all as specified and directed. |
| 69 | All as peritem No.39 but 4 pole 63-100 Amp Capacity 16 KA MCCB including dismantling the existing unserviceablecomplete all as specified and directed. |
| 70 | Supply and fix inLT Straight through joint heat shrinkable 1100 volts, 25 sqmm to 50 sqmm including dismantling the existing unserviceable complete all as specified and directed. |
| 71 | Supply and fix LT Straight through joint heat shrinkable 1100 Volts, 70 sqmm to 95 sqmm including dismantling the existing unserviceable complete all as specified and directed. |
| 72 | M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less \"than 1.5 metres below normal ground level, connected togalvanised iron strip 32×6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed. |
| 73 | M&L for earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mmthick buried directly in ground (earth pit not less than 2.25mdeep below normal ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected to galvanized iron wire 4.0 mm diaby means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore includingGI lightgrade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, complete all as specified and directed. |
| 74 | Supply, assembly, erection, testing and commissioning of Electrical panel cubical outdoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated as per CPRI approved make specified in CA, floor mounted free standing made out of 3.15mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 1000A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears,including suitable size of necessary PCC (1 : 3 : 6) type C2 as in foundation complete all as specified and directed. |
| 75 | a)Aluminium Bus bar 100 Amps capacity TPN, full for phase andneutral with colour code PVC sleeves. - 01 Job |
| 76 | b)LED RYB indicating lamps – 01 set |
| 77 | c) LED Ammeter and voltmeter with necessary CTs and displayof requiredrating . |
| 78 | d)MCCB 100Amp, 35KATPN, 415 Volts- 1 Nos (Incomer) |
| 79 | e)Change over Switch 100 Amps - 01 Nos |
| 80 | f) DOL Starter 15 HP- 01 Nos (Out going) |
| 81 | g)DOL Starter 3 HP - 01 Nos (Out going) |
| 82 | h)Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job |
| 83 | j)Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job |
| 84 | k)Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed- 1 Job |
| 85 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation, filling and coping shall be measured and paid separately under relevant item of this schedule. |
| 86 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Connection cable as required including PVC conduit pipe 20mm dia for protection of cable from Junction box to GI bracket complete all as specified and directed. |