| 1 | Dismantling of existingelectric passenger liftcapacity 08 Passengerlift with simplex type selective collective control catering of Ground + 05 floor comprises of car cabin enclosures, lift door, AC Motor, Control Panel, Traveling Cable, Hoist Way Rope, Main Driving Sheave,guide rail,brackets etc installed in ABHM complete all as specifiedand as directed.Note-: Contractor / OEM should ensure that all safety condition/ accessories as per latest IS / safety instruction on elevator are catered while quoting at ABHM |
| 2 | Supply, install, testing & commissioning 08 Passengers Lift suitable to serve for G+05 upper floorswith AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS : 14665, simplex collective selective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 2D infra red sensor in full height of door & built in announcing system with hand set (03 Nos, one eachin car& one near Ground floor landing door and one in machine room) complete all as specified below and as directed:- |
| 3 | NOTE :-Lift OEM to submit detailed specification/design parameters, construction drawing of all components of lifts as per IS-14665 and as per latest ammendement for approval of GE before execution of work.(a) Type of Lifts: Passenger(b) No. of Passengers & Load capacity: 08 Nos. & 544 Kg(c) Speed: 1.0 mtr/sec with single speed motor (d) Power Supply : 415 volts, 3 phase AC, 50 Hz(e) Type of Drive: AC variable voltage & variablefrequency drive. (f)Type of Machine: Gearless permanent magnet & directly coupled Horizontaltraction machine |
| 4 | (g) Car size (Inside): Not less than 1.43 sqm.(h) Car and landing door at all floors : Automatic centre opening with VVVF doordrive opening size not less than 800x2000 mm and sliding type fabricated by glass door andstainless steel sheet not less than 1.5 mm havinghair linefinish (N-304) the car and landing doors.(i)Car enclosure: manufactured with stainless steelframe not less than 1.5 mm with Hair line finish(N-304) having stainless steel false ceiling with hair line finish, Internal lighting arrangement with PIR sensor automatic operation LED light fittings on automatically in human presence with in 05 mtr range complete internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill wire mesh for protection as per OEM design. (j) Terminal buffers: Metal special spring buffers as per manufacturer specifications. |
| 5 | (k)Door opening (Inside): centre opening glass doors /stainless steel doors of size not less than 800x2000 mm. (l) Counter weight shall be of cast iron as recommended by OEM as per IS(m) Car counter weight guide :guide rails of ‘T’ section mild steel as per OEM design as per IS(n)Flooring: Aluminum chequred plate 5mm thick complete(o) Signals :-(i)Combined luminoushall buttonswith LCD/VFDhall position indicators at all floors.(ii) Vacuum Filled Display (LCD/VFD ) for car position indicator of stainless steel (iii) One Number car operating panel with luminous braille buttons with coloured LCD display.(iv) Car direction indicator in car & Landing.(v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. |
| 6 | (vi) Overload warning feature in car cabin.(Display and announcing type both)(vii) Fireman’s switch one No per lift to beinstalled at Ground Floor near landing door.(viii)All signal fixture & car operating panel on hair line stainlesssteel face plate with hair line finish.(ix)Infra red door sensor safety edge of door for entire height.(x)Built in announcing system with hand set (03 Nos, one each in car& onenear Ground floor landing door and onein machine room).(xi) The interior of the car shall be provided with a device that audibly announce the floor position of lift carhas reached and announce that car entrance/exit door is open or closed. |
| 7 | (p) Stops & Opening: Six ( All opening on same side).(q) Safety device : (i)Automatic rescue device (ARD)/automatic landing device to be operating with maintenancefree batteries having suitable capacity.The batteries must have auto charging facilities.(ii) The ARD actuation time should be less than twenty second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.(r) Operation: Simplex, full collective selective automatic operation with and without attendant. |
| 8 | (s) Machine room:- Located above the hoist way.(t) Hoist way construction; existing RCC structure with brick wall construction as existing at site.Total height from G/L to slab of Machine room can be seen at site before installation of lifts. (u) Control system shall be closed loop type.(v) Door shall have AC VVVF controlled door operator.(w) Faceplate shape shall be Rectangular and of stainless steel in hairline finish.(x) Civil work : Necessary civil work such as scaffolding in elevator shaft, cutting, making holes, grouting/welding barricading for all openings of elevators to avoid accidents & disturbances during pre and post erection of lift and making good disturbed surfaces, modifications to landing space to suit to car size, necessary foundation to machine, minor plastering of lift shaft wall etc and touch-up of white wash shall be applied on the lift shaft after completion of lift installation and all as per OEM recommendation/suggesting during execution of work. |
| 9 | (aa) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking,connect to complete cell and provn of through & other accessories as per OEM recommendation.(ab) Provn of governor and governor rope of suitable size ,buffer springs as per manufacture\"s design,car cabin having powered doors and inspection box at top of the car cabin.(ac)Provn of safety guarding equipments such as 02 Nos Pit switches controller guarding pit pulley,guarding pit ladders,facia plate to cover free space between car cabin and hoist way & switches. |
| 10 | (ad) Door sensor 81 beam, 2D infra red full length .(ae) provn of “Press and speak” system to be connected with liftexisting Intercom Exchange compatible with exchange.(af)Do\"s & Don\"ts chart on stainless steel to be installed inside the car cabin.(ag) Evacuation process chart to be installedinside the car cabin. Incase when lift stuck in midway shaft. The letters/Numbers in chart should be luminous radium coloured to see in all day/night time. |
| 11 | All as per srl item No. 2 to 2.08 here-in-before but for G+04 upper floors complete all as specified and as directed. |
| 12 | Supply and install in renewal of cubical type feeder pillar box CPRI approved dust and vermin proof factory made indoor type front opening with locking arrangement of size (LxWxD)60 x 45 x 30 cm made out of 2.00mm thick CRCA sheet (IS-8623) having arrangment for hanging on wall . The panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring, thimbles gland, cable lugs, nuts, bolts, washers, etc and having suitable arragement for fixing MCCB of 63 Amp TPN (01 No) and RCBO of 40 Amp TPN MCB (01 No) with all accessories. (Note :-01 x MCCB and 01 x RCBO both rates inclusive in above Job). |
| 13 | Material & Labour in renewal of earthing with galvanized steel earth plate electrode of size 60cmx60cmx6mm thick bured directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanized earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel using GI strip 32 X 6 mm as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40 mm dia GI medium grade earth strip protection pipe and pre-cast earth pit cover 80mm thick made of RCC (1:1:5:3) type A1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs, etc, mest, charcoal and common salt in alternate layer of 15cm thick complete all as specified & directed. |
| 14 | M&L in renewal of GI strip 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground. |
| 15 | Supply, laying and testing of cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core including taking down old cable complete all as specified and directed. |
| 16 | S&F in renewal of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar complete all as specified and as directed. |
| 17 | S&F in renewal of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar complete all as specified and as directed. |
| 18 | S&F of single pole, 06 to 32 Amps rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning including taking down old MCB\"s complete all as specified. |
| 19 | S&F of SPN 32 Amps rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning including taking down old MCB\"s complete all as specified and directed. |
| 20 | Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver completed all as specified and directed. |
| 21 | S&F ofRCBO 40 A, 300 mA 4P, 415 V, ACincluding taking down old RCBO complete all as specified and directed. |
| 22 | S&F of RCBO 25 A, 30 mA 2P, 240 V, ACincluding taking down old RCBO complete all as specified and directed. |
| 23 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied. |
| 24 | M&L for concealed point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in and including PVC concealed conduit ISI marked ofsuitable size medium grade with PVC conduit fittings such as tees, bends, elbow, reducers including cutting, chasing and making good to the disturbed surface, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing moduler switches/sockets etc with cover plate/3mm thick plastic laminated sheetfor one light / fan / exhaust fan / circulator fan / bell/ buzzer controlled by one way switch complete all as specified and directed . |
| 25 | All as per item No 16 but one light/fan/bell point controlled by one way switch 5 Amps. |
| 26 | All as per item No 16 but one 3 pin 5 Amps socket outlet point controlled by one way switch on same board. |
| 27 | All as per item No. 16here in before but with 3x2.5 Sqmm and (nominal area) FRLS PVC insulated un-sheathed andstranded copper conductor cable (phase, neutral and earth wire)for 15 Amp power point.complete all as specified and directed |
| 28 | S&F in renewal of socket outlet multipurpose 2/3 pin 5 Amps flush button type complete all as specified and directed. |
| 29 | S&F in renewal of switch piano flush button type 5 Amps single pole one way complete all as specified and directed. |
| 30 | S&F in renewal of switch piano flush button type 15 Amps single pole one way complete all as specified and directed. |
| 31 | S&F in renewal of socket outlet multi2 in 1, 5 and 15 Amps complete all as specified and directed. |
| 32 | S&F in renewal of ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed. |
| 33 | S&F LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old one complete all as specified and directed. |
| 34 | Section - II (B/R Portion)Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 35 | Material and labour for 20 mm thick black or any other colour granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 36 | M&L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishescomplete all as specified and directed. |
| 37 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed. |
| 38 | M&L for light shade or printed vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tile exc 0.36 sqm but not exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 39 | Demolition of brick work or stone / boulderor concrete block masonry includingall quoins, arches, pillars, etc. built in cement mortar complete all as specified. |
| 40 | M&L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 41 | Taking down cement or cement lime plaster of any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc. |
| 42 | M&L for rendering plaster 15 mm thick on fair faces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cement complete all as specified and directed. |
| 43 | M&L for rendering plaster 15mm thick in cement mortar 1:4 on concrete/brick surfaces, chajja or projectionsfinished even and smooth without using extra cement complete all as specified and directed. |
| 44 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of alkali resistand primer completeall as specified and directed. |
| 45 | M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening complete all as specified and directed. |
| 46 | Taking down door frames with shutters exc 1.50 sqm but not exc 4.00 sqm each (without taking off shutters from frame) complete all as specified and directed. |
| 47 | S&F powder coated aluminium frame for doors, windows, ventilators and sliding tracks, beading for grill with one or more rebates including joining cleat for fixing etc. complete all as specified and directed (min thickness of powder coating 50 micron) complete all as specified and directed. |
| 48 | S&F for powder coated anodised aluminium door shutters,aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittingssuitable handle (02 Nos.) with hydraulic door closer completeallasspecified and directed. |
| 49 | Taking down window frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) complete all as specified and directed. |
| 50 | S&F in renewal of steel door/window with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 51 | Supply and fixing sheet glass ordinary quality 5.5 mm thick,fixed to aluminium doors in squares exc 0.5 sqm in each pane complete all as specified and directed. |
| 52 | S&F in renewal of stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples and wooden beads upto four storied of building complete all as specified and as directed. |
| 53 | S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square in any size exc 0.5 sqm complete all as specified and directed. |
| 54 | Demolition of cement concrete of any description and in any positioncomplete inclall as specified and directed. |
| 55 | M&L for plain cement concrete (1:2:4) type B-1 using (20 mm graded crushed stone aggregate) as in levelling course/base padding, complete all as specified and directed. |
| 56 | M&L for preparation of old decorated plastered or un-plastered surface of walls, cornices, pilasters etc by brooming down scraping, filling all the nail holes etc and prepairing surface with plaster of paris etc and applying two coat of white wash on walls mixed with adequate qty of fevicol complete all as specified and directed. |
| 57 | All as per srl Item No 46 here-in-before but single coat on ceiling complete all as specified and directed. |
| 58 | M&L for preparation of old decorated plastered or un-plastered surface of walls, cornices, pilasters etc by brooming down scraping etc and applying two coat of cement base paint white or tinted complete all as specified and directed |
| 59 | M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 60 | All as per srl item No 49 here-in before but on steel surfaces complete all as specified and directed. |
| 61 | (xi) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge. |