| 1 | M&L for L-shaped work station, made of 18 mm thick rubber wood with melamine polish, 3 drawers and 2 shutters with locking system, UPS & CPU rack, key board tray with 8 mm thick glass top as per the size of key board tray. Partition of each station (180 x 150 x 110) cm and 10mm thick glass of 30 cm height on top of the each partition walls complete all as shown on drawing, specified and directed. |
| 2 | M&L for over head file rack of size 170Cm x 42Cm x 40Cm, made of 18 mm thick rubber wood with melamine polish with 1 shelf at 21cm above base and doors provided with suitable handle and locking arrangeemnt with and including suitable/ sufficient \" L\" angles for mounting facility complete all as shown on drawing, specified and directed. |
| 3 | M&L for file rack of size 200Cm x 70Cm x 40Cm,made of 18 mm thick rubber wood with melamine polish, file rack divided into 4 partitions with 4 shutters, each shutter have a locking system and handle with and including each compartmentprovided with a shelf at an equal distance complete all as shown on drawing, specified and directed. |
| 4 | M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including PVC Casing caping (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- |
| 5 | One 5 pin socket out let 5/6 Amp on independent board. |
| 6 | One 5 pin socket out let 5/6 Amp on same board. |
| 7 | Descrition same all as per item No 4 above, but with 4.0 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed. |
| 8 | S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 01 or equivalent of make as specified. |
| 9 | S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 11 or equivalent of make as specified. |
| 10 | S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specifiedand directed. Make: Legrand cat No: 6734 52 or equivalent of make as specified. |
| 11 | S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specifiedand directed. Make: Legrand cat No: 6734 55 or equivalent of make as specified. |
| 12 | S&F surface mounted plastic box suitable for the following module with and including modular cover plate & frame with all accessories complete all as specified and directed:- |
| 13 | 12 module. |
| 14 | 4 module. |
| 15 | S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with and including PVC casing caping of suitable size with standard accessories, of the following sizes of cable complete all as specified and directed:-NOTE :- Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and casing caping shall be measured as one unit. |
| 16 | 2x2.5 Sqmm+ 1x2.5 Sqmm earth wire |
| 17 | 2x4 Sqmm+ 1x4 Sqmm earth wire |
| 18 | 4x6 Sqmm+ 1x6 Sqmm earth wire |
| 19 | M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earthstrip of size 25x4 mm as earthing lead by means ofbolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009)withconected to eath test point including adequate quantity of charcoal dustand comman salt, PCC (1:3:6) type C-1chamber andfor earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both wayswith MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for wateringand 32mm dia medium earth lead protection pipe completeall as specified and directed.Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor. |
| 20 | S&F connecting & testing, distribution board, VTPN, sheet metalenclosures, double door, 415V, IP-43 protection suitable for 100/ 125 Amp, MCCB as incomer andoutgoings MCB’s TP/SP, of following capacity complete all as specified and directed :- |
| 21 | DB 4 way Make : Legrand, Cat Part No. 5077 25 or equivalent make as specified. |
| 22 | S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 415V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps ratinghaving following capacity complete all as specifiedanddirected:- |
| 23 | DB TPN, 4 wayMake : Legrand Cat Part No. 5076 70 or equivalent others make as specified. |
| 24 | S&F MCCB 50 Hz, 415 V, adjustable type, having thermal magnetic release of following capacity complete all as specified and directed :- |
| 25 | 100Amp, 4 Pole,Icu= 25 KA,Make : Legrand, Cat Part No. 4200 55 or equivalent make as specified. |
| 26 | S&F connecting & testing MCB, 230V/ 415Vwith rupturing capacity 10 KA of following capacity complete all as specified and directed:- |
| 27 | MCB 6 to 32 Amp, SP, \"C\" series/ curve, Make :-Legrand, Cat Part No 4085 87 to 4085 95 or equivalent others make as specified. |
| 28 | MCB 40 to 63 Amp, TPN, \"C\" series/ curve, Make :-Legrand, Cat Part No 4086 81 to 4086 83 or equivalent others make as specified. |