| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out from any type of soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning,filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for 75mm thick PCC (1:4:8) type-D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre. |
| 9 | M&L anti skid coloured ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed by Engr-in-Charge |
| 10 | M&Lglazed ceramic coloured, designer & pattern (dark & light shade combination) tilesin 350x250x7 or450x350x7 or 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:4complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L Granite work 18-20mm thick (Table rubbed and polished) in cooking platforms and like set in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shede complete all as per specified and as directed. |
| 12 | M&L for rounding the edge of stone slab one edge such as in steps, cooking plateform and other similar work complete all as per specified and as directed. |
| 13 | S&F 60mm thick coloured precast cement concrete interlocking paver block of required shape and size made with electrovabro technology conforming to IS of M-35 grade laid over with and including 25mm thick dry sand cushion complete all as specidied and directed by Engr-in-Charge. |
| 14 | M&L for 75mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or paving, finishing cement concrerte surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 15 | Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F mild steel TMT bar10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 17 | M&L RCC 1:2:4type B-1 using 20mm graded stone aggregate as in slab supported on wall, landings balconies, canopies, deck slabs and shelves etc complete all as specified and directed |
| 18 | M&L for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement 1:4 complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F 20 mm dia steel water GI tube medium grade with all fittings and fixed with walls, ceilings or laid in floors complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L Lagging to pipes used in internal water supply (internal dia of pipe 20mm) or plumbing all round with,25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 all as specified and directed by the Engr-in-Charge. |
| 22 | S&F Vitrous china wash hand basin, oval shape counter top of size 550 x 400 mm white fixed to RCC counter with and, 32mm dia PTMT waste coupling and 32mm dia PVC waste pipe 90cm long etc inlet and outlet connection ,inclcutting of stone wall/brick wallcomplete all as specified and directed by Engr-in-Charge. |
| 23 | S&F 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 24 | S&F CP angle valves (half turn type) concealed type (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed. |
| 25 | S&F 15 mm dia CP Central Hole Basin Mixer without Pop-up waste system complete all as specified and directed. |
| 26 | S&F single/multi PVC (SWR) floor trap 75mm to 110mm dia, palin with grating including joining to waster pipe, fixed in cement concrete type B-1 (1:2:4) using 20mm graded broken stone aggregate complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps complete all as specified and as directed |
| 28 | S&F 75 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps complete all as specified and as directed |
| 29 | S&F 110 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed |
| 30 | S&F 75 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed |
| 31 | M&L Reinforced NP2 pipe of 150 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L PCC 1:2:4 type B1 (12.5mm graded aggregate) in mud stops rounded or chamfered on edgesof tiles complete all as specified and directed. |
| 33 | S&Frotational mouldedpolythenewaterstorage tank 2000 ltrs(cylindricalvertical with closed top) hoistedand fixed in position all as specified inSSR Part-I with including 20mmball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule & nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) complete all as specified and directed by Engr -in-Charge. |
| 34 | S&F in repairs 20 mm PP-R Gate valves (brass insert) as per requirement of the site, complete all as specified and directed. |
| 35 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr -in-Charge. |
| 36 | S&F mild steel Fe 410-W Qty as in joist, channel, angle or tee sections fixed independently without connecting plates etc all as specified and directed by Engineer-in-Charge. |
| 37 | S&F 1.00 mm thick plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) for top of Water tank staging or any were reqd all as specified and directed by Engineer-in-Charge. |
| 38 | M&L PCC (1:2:4) B-2 (40 mm graded) in foundation, filling and mass concrete for fixing of angle iron work inccluding necessary form work and allied work complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L PCC 1:2:4 type B0 12.5mm graded aggregatte as in hold fasts and bed blocks etc including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensilestrength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 41 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 42 | S&F Powder coated galvanised iron frame work for seamless ceiling size 600mm x 600mm with main runner 38 x 24 x 0.90mm thick, cross tee 29 x 24 x 0.90mm thick and wall angle 24 x 24 x 0.90mm thick duly suspended with 6mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip complete all as specified and as directed. |
| 43 | S&F 8mm thick Non Asbestos fibre cement building boards/Pre Laminated self embossed texture designer E-Board classic(Size 0.60M x 0.60M/0.60M x 1.2 M), HPSC (High pressure steam cured) to be fixed or laid/inserted to existing/new timber/GI/Aluminium/MS framework with screws as in ceiling complete all as specified and directed. |
| 44 | M&L preparing new/old plastered surface of walls and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed complete all as specified and directed by Engr -in-Charge. |
| 45 | M&L three coats of white wash on new/old plastered surfaces of ceiling including preparation of surfacces complete all as specified and directed by Engr-in-Charge. |
| 46 | M&L for Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 47 | M & L for point wiring complete with, PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694including medium duty surface mounted unplasticised PVC conduit conforming to IS : 9537 ( Part-3) andISI marked not less than 20 mm diawith surface mountedpressed steelterminal boxes not less than 1.6 mm thick of required. size (factory made)includingtop cover 3 mm thick of plastic laminated sheets of required colour for fixing switches complete with all accessories and all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour asearth wire to common earth and connected to earth dolly drawn in same concealed conduit completefor following:- |
| 48 | (a) One light/fan point controlled by oneway switch |
| 49 | (b) One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 50 | (c) One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 51 | All as per item No 47.00 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 52 | M&L for ceiling rose, surface polycarbonate isolated body three terminals. |
| 53 | M&L switch piano flush type 5 Amp SP one way . |
| 54 | M&L socket outlet6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 55 | M&L switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge . |
| 56 | M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 57 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 58 | S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete |
| 59 | Supply and fixin repair MCB DP 63 Amps 240 volts 10 KA 50 HZ \"B\" curve complete all as specified and directed by Engineer in charge |
| 60 | Supply and fixin repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"B\" curve complete all as specified and directed by Engineer in charge |
| 61 | S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified. |
| 62 | Supply & Fix in replacement MCCB 160 Amp, 36 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge. |
| 63 | M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed. |
| 64 | S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 65 | Supply, installation, testing and commissioning of commercial Reverse Osmosis system (RO-500 Ltr/hr capacity or near higher size with suitable raw water and reated waterstorage tank capacity 5000 ltr oncluding all necessary arrangment for fixing /installation and electric connection grom electric point and water connection for outlet raw water tank to RO and RO to inlet of treated water and storage tank. The plant shall be installed indoor and shall be able to operate in temperature range up to (-) 15 degree Celsius. Arrangement and piping of waste water disposal upto outside the building is including in the cost The output water has to be got tested from authorised rep and should meet the IS requirements of drinking water. Cost of testing is deemed to be included in the quoted rates. Any other items required to make the plant functional will also be provided by the contractor included in the rate quoted.NOTE:- (i) AMC for commercial RO plantof capacity 500 Ltr/hr (Replacement of RO Membrane (Once in year)=02 Nos , Replacement of sediment Filter Quarterly=02 Nos, TDS checking and cleaning of rotor meters, replacement of Bag Filter in six months=01 Nos, Refilling of anti scalant Chemical 05 Ltrs).(ii) Cotractor has to quote their rates inclusive of AMC for two years from the date of physical completion of the work. Nothing shall be extra admissible to the contractor on this account.(iii) Contractor shall submit an FDR in favour of GE 970 EWS as security deposit against AMC @ 1% of Quoted rate of RO Plant at the time of issue of completion. The said FDR shall be released after expiry of AMC period i.e. 02 (Two) years from satisfactory completion of the subject CA. |
| 66 | Supply and Layingjointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 4 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 67 | Supplying, laying sand cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected |
| 68 | Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection complete all as specified and directed. |
| 69 | Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed. |
| 70 | Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 32 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc. |
| 71 | Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 25 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc. |
| 72 | Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 20 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc. |
| 73 | Supply & Fix making connection of PPR distribution branch with PPR main ofsizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 74 | Supply & Fix PP-R Gate valves (brass insert) ISI markedof external dia 32 mm as per requirement of the site and as directed by Engineer-in Charge. |
| 75 | Supply & Fix PP-R Gate valves (brass insert) ISI markedof external dia 25 mm as per requirement of the site and as directed by Engineer-in Charge. |
| 76 | Supply & Fix PP-R Gate valves (brass insert) ISI markedof external dia 20 mm as per requirement of the site and as directed by Engineer-in Charge. |
| 77 | Supply and installation of copper wound transformer step up/ step down, indoor/outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 200 KVA (against BER) complete all as specified and directed by Engr-in-Charge. |
| 78 | Supply and Layingjointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 185 Sqmm 3.5 core complete fixed to trench/ floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 79 | Supply and install hi wall split units indoor/ outdoor inverter type complete with cordless remotecontrol unit and with in built air heating and cooling arrangement and ioniser & plasma filtewr for better indoor air quality and digital inverter twin rotary of capacity 1.5 TR . BEE 5 star rated and eco friendly refrigerent complete all as specified and as directed by Engr-In-Charge. |
| 80 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVAcomplete all as specified and as directed by Engr-In-Charge. |
| 81 | M&L for additional lenghth ofCopper pipe for installing split type air conditioner at site of suitable size /guage complete allas directed by Engineer in Charge.Note Additional quantity both suction and discharge pipe has cosidered as one RM) complete all as specified and as directed by Engr-In-Charge.. |
| 82 | Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6.00 mm thick buried directly in ground(Earth pit not less than 2.25 metre below normal ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected and including GI strip 32mm x 6mm by means of GI bolts, nuts, check nuts and washers, earth plate surrounded by packed alternatelayers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh and 50mm bore GI pipe light grade for protection of GI strip 32mmx6mm from top of earth plate upto test point (upto 7.5metre in length) connected with suitable size of GI nuts, bolts and washersall as shown in Electrical plate No. 3 of SSR Part-I, testing on completion including excavation/earth work in any type of soil/rock, PCC chamber (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways with suitable handle for lifting arrangement & including formwork and MS frame using MS angle iron 40x40x6mm complete all as specified and directed.Note :- Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit complete all as specified and as directed by Engr-In-Charge. |
| 83 | Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100KVA complete all as specified and directed by Engr-in-Charge. |
| 84 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5core complete all as specified and directed by Engr-in-Charge. |
| 85 | Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 50 Sqmm 3.5 core with aluminium conductor laid in trenches/pipes, fixed topoles/walls with suitable saddle complete all as directed. |
| 86 | S & FLT Control panel board, Outdoor type,double door, cubical type,Sloppy roof front and back both side openable door, padestal mounted,CPRI approved with IP-54, overall size not less than 1200 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheetsuitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminiumbus bar of600 Amp rating for 3 phase and neutral4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Setincl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar ofGI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coatingin siemens grey colour and provision for the following incoming and out going accessories all as approved andcomprising as under : Drawing of panal shall bebe approved by GE before commencement of works at site. Incoming :-(a)MCCB 4 Pole,400 Amp, 36 KA415V,Adjustable thermal setting type - 01 No. (b) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch- 01 Set(c) Digital Amp Meter 0 - 400 Amp, size 96x96 mm square type with selector switch - 01 Set. (d) Copper wound with CTR 400/5 - 01 set. (e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- (a)MCCB 4 Pole, 100 Amp, 16 KA415V,Adjustable thermal setting type - 02 Nos. (b)MCCB 4 Pole, 63 Amp, 16 KA415V,Adjustable thermal setting type - 05 Nos. (c)MCB TPN, 32/40 Amp415V - 03 Nos. b) Angle iron base frame made out of ISA 5050 ofsize 50 x 50 x 6 mm thick incl PCC 1:3:6 (40 mm grade aggregate) type C2 for foundation , total leg height 600 mm above ground level - 01 Jobc) Three phase timer switch 20 amp - 01 No |
| 87 | S & FLT Control panel board, Outdoor type,double door, cubical type,Sloppy roof front and back both side openable door, padestal mounted,CPRI approved with IP-54, overall size not less than 1500 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheetsuitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminiumbus bar of1200 Amp rating for 3 phase and neutral4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Setincl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar ofGI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coatingin siemens grey colour and provision for the following incoming and out going accessories all as approved andcomprising as under : Location : NearTransformer. Incoming :- a)MCCB 4 Pole,630 Amp, 50 KA415V,Adjustable thermal setting type - 01 No. b) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch- 01 Set c) Digital Amp Meter 0 - 700 Amp, size 96x96 mm square type with selector switch - 01 Set.d) Copper wound with CTR 700/5 - 01 set.e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- a)MCCB 4 Pole,200 Amp , 36 KA 415V,Adjustable thermal setting type - 02 Nos. a)MCCB 4 Pole,100 Amp, 16 KA415V,Adjustable thermal setting type - 02 Nos. a)MCCB 4 Pole, 63 Amp, 16 KA415V,Adjustable thermal setting type - 01 Nos. b) Angle iron base frame made out of ISA 5050 ofsize 50 x 50 x 6 mm thick incl PCC 1:3:6 (40 mm grade aggregate) type C2 for foundation , total leg height 600 mm above ground level - 01 Jobc) Three phase timer switch 20 amp - 01 No |
| 88 | M&L Earthing complete with copper earth plate electrode size 600mm x 600mm x 3.15 mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connectedwith and including copper strip of size 20x 3 MM by means of bolts and nutscheck nut and washers with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth strip upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion complete all as specified and directed. Note :- (i) RCC pit cover shall be pre cast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lie if CI cover and the rate includes in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate.(iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate. |
| 89 | S & F in repairs GItubing light grade 50 mm dia for road crossing and cable protection etc complete all as specified and directed by Engr In Charge. |
| 90 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation complete all as specified and directed by Engr-in-Charge. |
| 91 | M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work complete all as specified and directed by Engr-in-Charge. |
| 92 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail